고등학교 교실의 조명 환경 특성 연구

A Study on the Characteristics of Lighting Environment in High School Facilities

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류학제간연구

초록

Criteria of interior lighting in high school classrooms based on KS A 3011 is "G". But the lighting environment for occupants in classrooms is changed according to various factors. So characteristics of lighting environment should be surveyed and analyzed. One classroom in S high school and five classrooms in C high school were chosen. Their lighting levels and conditions were checked during lessons. Also the lighting levels of different lighting conditions and the response of students were checked too. During lessons, all lighting levels measured were in the adequate criteria, as a minimum 640lx. Uniformity ratio of illuminance was 0.16 ~ 0.29 in S highschool and 0.53 ~0.87 in C high school. When the lighting of window side were turned off in classroom, the lighting levels of S high school were in the adequate criteria as a minimum 534lx but the lighting levels of C high school were not in the afternoon. When the all lighting in classrooms were off, the all lighting levels of two high school were not in the adequate criteria. When the lighting of window side were turned off in classroom specially, most students were satisfied and the energy saving of 17,689,309kWh annually is expected in all high schools

Abstract

Criteria of interior lighting in high school classrooms based on KS A 3011 is "G". But the lighting environment for occupants in classrooms is changed according to various factors. So characteristics of lighting environment should be surveyed and analyzed. One classroom in S high school and five classrooms in C high school were chosen. Their lighting levels and conditions were checked during lessons. Also the lighting levels of different lighting conditions and the response of students were checked too. During lessons, all lighting levels measured were in the adequate criteria, as a minimum 640lx. Uniformity ratio of illuminance was 0.16 ~ 0.29 in S highschool and 0.53 ~0.87 in C high school. When the lighting of window side were turned off in classroom, the lighting levels of S high school were in the adequate criteria as a minimum 534lx but the lighting levels of C high school were not in the afternoon. When the all lighting in classrooms were off, the all lighting levels of two high school were not in the adequate criteria. When the lighting of window side were turned off in classroom specially, most students were satisfied and the energy saving of 17,689,309kWh annually is expected in all high schools

참고문헌 (6)

  1. 김진구, "초등학교 교실조명과 학생시력 변화의 관계분석 및 교실조명개선에 관한 연구", 조명.전기설비학회논문지, 19(1), pp.15~23 (2005), 한국조명.전기설비학회
  2. 김현지, "대형 공동주택 거실 조명환경과 행위별 조명사용에 관한 조사연구", 조명.전기설비학회논문지, 26(3), pp.1~8 (2012), 한국조명.전기설비학회
  3. 박동화, "교실의 조도분포 분석", 한국조명·전기설비학회 1996년도 추계 학술대회논문집, pp.34~36 (1996)
  4. 신현만, "시뮬레이션 프로그램을 활용한 교실조도 분석 및 개선방안", 조명.전기설비학회논문지, 23(6), pp.14~23 (2009), 한국조명.전기설비학회
  5. 지순덕, "학교 교실 LED 조명의 색온도에 대한 주관적 평가", 조명.전기설비학회논문지, 25(1), pp.30~41 (2011), 한국조명.전기설비학회
  6. 최미향, "고령자의 주택조명환경실태조사", 한국조명·전기설비학회 학술대회논문집, pp.235~238 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (19건)