세 가지 방식의 스캐너 종류에 따른 모형 정확도 평가
Evaluation of the Model Accuracy according to Three Types of Dental Scanner
1
조회
0
다운로드
9
인용
0
참고문헌
키워드
초록
본 연구는 세 가지 종류 스캐너에 따른 정확도를 비교 평가하기 위하여 시행되었다. 경석고 모형과 스캐너로 채득한디지털 모형에 각 4지점씩 계측지점을 선정하였고, 이들 4 지점사이를 DVC와 디지털 모형 측정 프로그램을 이용하여길이를 측정하고, 다음과 같은 결론을 도출하였다. 세 가지종류의 스캐너 가운데 레이저 스캐너가 백색광 스캐너나 청색광 스캐너보다 높은 정확도를 나타내었으나 이 세 가지종류의 스캐너 모두가 임상적으로 사용하는 것이 가능하다.
Abstract
The purpose of this study was to evaluate the accuracy of model according to three types of dental scanner. A maxillary acrylic model was prepared and duplicated 10 times by silicone impression materials. Corresponding working casts were formed from scannable stone and got a 3-dimensional digital models using three different scanners. The distance of each measurement region was measured using vernier calipers and the respective program. One-way ANOVA and the Tukey honestly significant difference post hoc test (α=0.05) was performed using IBM SPSS Statistics 21.0. Overall, the stone cast is smaller than the digital models in measurement distance. And measuring point value of laser scanner showed the most similar values and measurement points value of digital vernier calipers. Digital model of white light scanner showed similar values in the measurement points value of the blue light scanner. In conclusion, the laser scanner showed the best accuracy among the three types of dental scanner. However, the difference between the digital models and the stone cast can be accommodated in making prostheses. Thereby, three types of dental scanner are available in a clinically acceptable range.
참고문헌 (22)
- Miyazaki T, "A review of dental CAD", CAM: current status and future perspectives from 20 years of experience, 2009, pp.28, 44~56
- Christensen GJ, "The state of fixed prosthodontic impressions:room for improvement", J Am Dent Assoc, 136, pp.343~346 (2005)
- Felton D, "Effect of in vivo crown margin discrepancies on periodontal health", J Prosthet Dent, 65, pp.357~364 (1991)
- Duan Y, "Effect of elasticity on stress distribution in CAD", CAM dental crowns: glass ceramic vs. polymermatrix composite, 2015, ~
- Persson A, "A three-dimensional evaluation of a laser scanner and a touchprobe scanner", J Prosthet Dent, 95, pp.194~200 (2006)
- 전진훈, "Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision", The Journal of Advanced of Prosthodontics, 6(6), pp.468~473 (2014), 대한치과보철학회[DOI]
- May KB, "Precision of fit: the procera all ceram crown", J Prosthet Dent, 80, pp.394~404 (1998)
- Mehl A, "A new optical 3-D device for the detection of wear", J Dent Res, 76, pp.1799~1807 (1997)
- Rudolph H, "Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD", CAM technology, 2007, pp.37, 579~587
- 전진훈, "White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions", The Journal of Advanced of Prosthodontics, 5(4), pp.452~456 (2013), 대한치과보철학회[DOI]
- Perakis N, "Final impressions: a review of material properties and description of a current technique", Int J Periodontics Restorative Dent, 24, pp.109~118 (2004)
- Persson AS, "Digitization of simulated clinical dental impressions: virtual three-dimensional analysis of exactness", Dent Mater, 25, pp.929~936 (2009)
- Kim SY, "Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging", Int J Prosthodont, 26, pp.161~163 (2012)
- Flügge TV, "Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner", Am J Orthod Dento facial Orthop, 144, pp.471~478 (2013)
- Güth JF, "Accuracy of digital models obtained by direct and indirect data capturing", Clin Oral Investig, 17, pp.1201~1208 (2013)
- Cho SH, "Comparison of accuracy and reproducibility of casts made by digital and conventional methods", J Prosthet Dent, 113, pp.310~315 (2015)
- Bernal C, "Performance evaluation of optical scanner based on blue LED structured light", Proc Eng, 63, pp.591~598 (2013)
- 김재홍, "Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique", 대한치과교정학회지, 44(2), pp.69~76 (2014), 대한치과교정학회
- 김재홍, "인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적안정성 평가", 치위생과학회지, 14(1), pp.15~21 (2014), 한국치위생과학회
- Kobayashi Y, "The effect of proximal teeth on the digitizing accuracy of the shoulder margin of the crown abutment by a laser digitizer equipped in an experimentally developed CAD", CAM device., 2000, pp.20, 158~164
- Santoro M, "Comparison of measurements made on digital and plaster models", Am J Orthod Dentofacial Orthop, 124, pp.101~105 (2003)
- Park S, "An enhanced method for registration of dental surfaces partially scanned by a 3D dental laser scanning.", Comput Method Progr Biomed, 118, pp.11~22 (2015)