The current standard approach to measuring home blood pressure (BP) involves taking measurements while sitting in a chair. In cultures where floor sitting is common, including Korea, assessing BP while sitting on the floor would be more feasible. However, there is still a lack of research investigating whether BP measurements obtained while seated in a chair and while sitting on the floor can be regarded as interchangeable. The aim of the study was to evaluate whether there is a difference between BP measurements taken while sitting in a chair and while sitting on the floor in a Korean adult.Among the participants who visited for evaluation of pulse wave velocity, a total of 116 participants who agreed to participate in the study were randomly selected. All subjects rested for 5 min, and BP measurements were taken at 1-min intervals according to a randomly assigned order of standard method (chair-sitting) and BP in a seated on the floor (floor-sitting). Of the 116 participants, the median age was 68 (with an interquartile range of 59 to 75), and 82% were men. There were no significant differences in systolic BP (SBP, 129.1 ± 17.8 mmHg in chair-sitting and 130.1 ± 18.9 mmHg in floor-sitting, P = 0.228) and diastolic BP (DBP, 73.9 ± 11.4 mmHg in chair-sitting and 73.7 ± 11.4 mmHg in floor-sitting, P = 0.839) between the two positions. In addition, there was a high level of agreement between BP measurements taken in the two positions (intraclass correlation coefficients: 0.882 for SBP and 0.890 for DBP). These findings provide important insights into securing the reliability of home BP measurements through the commonly practiced floor-sitting posture in cultures where floor sitting is common. Furthermore, this could serve as substantial evidence for providing specific home BP measurement guidelines to patients who adhere to a floor-sitting lifestyle.

Abstract

Background The current standard approach to measuring home blood pressure (BP) involves taking measure‑ ments while sitting in a chair. In cultures where foor sitting is common, including Korea, assessing BP while sitting on the foor would be more feasible. However, there is still a lack of research investigating whether BP measure‑ ments obtained while seated in a chair and while sitting on the foor can be regarded as interchangeable. The aim of the study was to evaluate whether there is a diference between BP measurements taken while sitting in a chair and while sitting on the foor in a Korean adult. Methods Among the participants who visited for evaluation of pulse wave velocity, a total of 116 participants who agreed to participate in the study were randomly selected. All subjects rested for 5 min, and BP measurements were taken at 1-min intervals according to a randomly assigned order of standard method (chair-sitting) and BP in a seated on the foor (foor-sitting). Results Of the 116 participants, the median age was 68 (with an interquartile range of 59 to 75), and 82% were men. There were no signifcant diferences in systolic BP (SBP, 129.1±17.8 mmHg in chair-sitting and 130.1±18.9 mmHg in foor-sitting, P=0.228) and diastolic BP (DBP, 73.9±11.4 mmHg in chair-sitting and 73.7±11.4 mmHg in foor-sitting, P=0.839) between the two positions. In addition, there was a high level of agreement between BP measurements taken in the two positions (intraclass correlation coefcients: 0.882 for SBP and 0.890 for DBP). Conclusion These fndings provide important insights into securing the reliability of home BP measurements through the commonly practiced foor-sitting posture in cultures where foor sitting is common. Furthermore, this could serve as substantial evidence for providing specifc home BP measurement guidelines to patients who adhere to a foor-sitting lifestyle.

참고문헌 (23)

  1. Stergiou GS, "2021 European Society of Hypertension practice guidelines for office and out-of-office blood pressure measurement", J Hypertens, 39(7), pp.1293~1302 (2021)
  2. Kim HL, "The 2022 focused update of the 2018 Korean Hypertension Society Guidelines for the management of hypertension", Clin Hypertens, 29(1), pp.11~ (2023)
  3. Shin J, "Impact of a screening protocol for blood pressure level for hypertension in the Korean community health survey", Blood Press, 30(6), pp.403~410 (2021)
  4. Mancia G, "2023 ESH Guidelines for the management of arterial hypertension The Task Force for the management of arterial hypertension of the European Society of Hypertension : Endorsed by the International Society of Hypertension(ISH)and the European Renal Association(ERA)", J Hypertens, 41(12), pp.1874~2071 (2023)
  5. Ihm SH, "Home blood pressure monitoring : a position statement from the Korean Society of Hypertension Home Blood Pressure Forum", Clin Hypertens, 28(1), pp.38~ (2022)
  6. Kim BS, "Blood pressure and variability responses to the down-titration of antihypertensive drugs", J Hypertens, 42, pp.809~815 (2024)
  7. Nagrajan A, "Using the newly developed floor-sitting movement analysis proforma to study the effect of age and activity on floor-sitting in Indian adults", J Cross Cult Gerontol, 32(1), pp.71~93 (2017)
  8. Fujita K, "Changes in the WOMAC, EuroQol and Japanese lifestyle measurements among patients undergoing total hip arthroplasty", Osteoarthritis Cartilage, 17(7), pp.848~855 (2009)
  9. Moon MS, "Spinopelvic orientation on radiographs in various body postures : upright standing, chair sitting, Japanese style kneel sitting, and Korean style cross-legged sitting", Clin Orthop Surg, 10(3), pp.322~327 (2018)
  10. Shim H, "The effect of posture on the human thermoregulatory response", J Korean Soc Cloth Text, 17, pp.415~427 (1993)
  11. Choi S, "Comparison of the accuracy and errors of blood pressure measured by 2 types of non-mercury sphygmomanometers in an epidemiological survey", Medicine(Baltimore), 97(25), pp.e10851~ (2018)
  12. Kim H-L, "Standardized protocol of blood pressure measurement and quality control program for the Korea National Health and Nutrition Examination Survey", Clin Hypertens, 29(1), pp.28~ (2023)
  13. Muntner P, "Measurement of blood pressure in humans : a scientific statement from the American Heart Association", Hypertension, 73(5), pp.e35~e66 (2019)
  14. Satoh M, "Is antihypertensive treatment based on home blood pressure recommended rather than that based on office blood pressure in adults with essential hypertension?(meta-analysis)", Hypertens Res, 42(6), pp.807~816 (2019)
  15. Mancia G, "Diagnosis and management of patients with white-coat and masked hypertension", Nat Rev Cardiol, 8(12), pp.686~693 (2011)
  16. Zahid H, "Prevalence and predictors of use of home sphygmomanometers among hypertensive patients", Cureus, 9(4), pp.e1155~ (2017)
  17. Baral-Grant S, "Self-Monitoring of blood pressure in hypertension : a UK primary care survey", Int J Hypertens, 2012, pp.582068~ (2012)
  18. Vickneson K, "Factors influencing participation and long-term commitment to self-monitoring of blood pressure in a large remote clinical trial : The treatment in morning versus evening(TIME)study", J Hum Hypertens, 36(12), pp.1099~1105 (2022)
  19. Nessler K, "The quality of patients’ self-blood pressure measurements : a cross-sectional study", BMC Cardiovasc Disord, 21(1), pp.539~ (2021)
  20. Nessler K, "The reliability of patient blood pressure self-assessments-a cross-sectional study", BMC Prim Care, 24(1), pp.2~ (2023)
  21. Merrick RD, "Factors influencing the accuracy of home blood pressure measurement", South Med J, 90(11), pp.1110~1114 (1997)
  22. Tolonen H, "Challenges in standardization of blood pressure measurement at the population level", BMC Med Res Methodol, 15, pp.33~ (2015)
  23. Kallioinen N, "Sources of inaccuracy in the measurement of adult patients’ resting blood pressure in clinical settings : a systematic review", J Hypertens, 35(3), pp.421~441 (2017)

관련 논문AI추천

Association of blood pressure measurements in sitting, supine, and standing positions with the 10-year risk of mortality in Korean adults신철, 김난희, 김성환, Baik Inkyung한국역학회 · Epidemiology and Health2023 · 제45권 Differences in Blood Pressure Measurements Obtained Using an Automatic Oscillometric Sphygmomanometer Depending on Clothes-Wearing Status기지훈, 오미경, 이수희대한가정의학회 · Korean Journal of Family Medicine2013 · 제34권 제2호Diagnostic accuracy of manual office blood pressure measurement in ambulatory hypertensive patients in KoreaChang-Hwan Yoon, Dong-Ju Choi, Doo Ryeon Chung, Goo-Yeong Cho, Hae-Young Lee, Il-Young Oh, In Ho Chae, Jinho Shin, Jin Joo Park, Jung-Won Suh, Sehun Kim, Seung-Ah Lee, Sungha Park, Yeonyee E. Yoon, Youngjin Cho, Young-Seok Cho대한내과학회 · The Korean Journal of Internal Medicine2018 · 제33권 제1호Home blood pressure monitoring: a position statement from the Korean Society of Hypertension Home Blood Pressure Forum김광일, 김주한, 김철호, 박성하, 박재형, 신진호, 이은미, 이해영, 임상현, Kim Jang Young대한고혈압학회 · Clinical Hypertension2022 · 제28권 Inter-arm Differences in Simultaneous Blood Pressure Measurements in Ambulatory Patients without Cardiovascular Diseases기지훈, 김경복, 김수민, 김하경, 오미경, 이수희대한가정의학회 · Korean Journal of Family Medicine2013 · 제34권 제2호Validation of the iHealth-BP7 and Withings-BP800 blood pressure monitor for self-measurement according to the European Society Hypertension International Protocol revision 2010강성기, 안현성, 이정민한국체육측정평가학회 · 한국체육측정평가학회지2016 · 제18권 제3호

이 간행물의 다른 논문 (35건)