Home blood pressure monitoring: a position statement from the Korean Society of Hypertension Home Blood Pressure Forum
2
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
Home blood pressure measurement (HBPM) has the advantage of measuring blood pressure (BP) multiple times over a long period. HBPM effectively diagnoses stress-induced transient BP elevations (i.e., white coat hypertension), insufficient BP control throughout the day (i.e., masked hypertension), and even BP variability. In most cases, HBPM may increase self-awareness of BP, increasing the compliance of treatment. Cumulative evidence has reported better improved predictive values of HBPM in cardiovascular morbidity and mortality than office BP monitoring. In this position paper, the Korean Society of Hypertension Home Blood Pressure Forum provides comprehensive information and clinical importance on HBPM.
Abstract
Home blood pressure measurement (HBPM) has the advantage of measuring blood pressure (BP) multiple times over a long period. HBPM effectively diagnoses stress-induced transient BP elevations (i.e., white coat hypertension), insufficient BP control throughout the day (i.e., masked hypertension), and even BP variability. In most cases, HBPM may increase self-awareness of BP, increasing the compliance of treatment. Cumulative evidence has reported better improved predictive values of HBPM in cardiovascular morbidity and mortality than office BP monitoring. In this position paper, the Korean Society of Hypertension Home Blood Pressure Forum provides comprehensive information and clinical importance on HBPM.
참고문헌 (88)
- Tanabe A, "Left ventricular hypertrophy by electrocardiogram as a predictor of success in home blood pressure control : HOMED-BP study", Hypertens Res, 40, pp.504~510 (2017)
- Shibamiya T, "Electrocardiographic abnormalities and home blood pressure in treated elderly hypertensive patients : Japan home versus office blood pressure measurement evaluation in the elderly(J-HOME-Elderly)study", Hypertens Res, 33, pp.670~677 (2010)
- Shimbo D, "Relative utility of home, ambulatory, and office blood pressures in the prediction of end-organ damage", Am J Hypertens, 20, pp.476~482 (2007)
- Niiranen T, "Home-measured blood pressure is more strongly associated with atherosclerosis than clinic blood pressure : the Finn-HOME Study", J Hypertens, 25, pp.1225~1231 (2007)
- Stergiou GS, "Home blood pressure is as reliable as ambulatory blood pressure in predicting target-organ damage in hypertension", Am J Hypertens, 20, pp.616~621 (2007)
- Asayama K, "Prediction of stroke by self-measurement of blood pressure at home versus casual screening blood pressure measurement in relation to the Joint National Committee 7 classification : the Ohasama study", Stroke, 35, pp.2356~2361 (2004)
- Fagard RH, "Prognostic significance of blood pressure measured in the office, at home and during ambulatory monitoring in older patients in general practice", J Hum Hypertens, 19, pp.801~807 (2005)
- Niiranen TJ, "Homemeasured blood pressure is a stronger predictor of cardiovascular risk than office blood pressure : the Finn-Home study", Hypertension, 55, pp.1346~1351 (2010)
- Ohkubo T, "Home blood pressure measurement has a stronger predictive power for mortality than does screening blood pressure measurement : a population-based observation in Ohasama", Japan J Hypertens, 16, pp.971~975 (1998)
- Sega R, "Prognostic value of ambulatory and home blood pressures compared with office blood pressure in the general population : follow-up results from the Pressioni Arteriose Monitorate e Loro Associazioni(PAMELA)study", Circulation, 111, pp.1777~1783 (2005)
- Bobrie G, "Cardiovascular prognosis of"masked hypertension"detected by blood pressure self-measurement in elderly treated hypertensive patients", JAMA, 291, pp.1342~1349 (2004)
- Stergiou GS, "Reproducibility of home, ambulatory, and clinic blood pressure : implications for the design of trials for the assessment of antihypertensive drug efficacy", Am J Hypertens, 15(2 Pt 1), pp.101~104 (2002)
- Eguchi K, "Visit-to-visit and ambulatory blood pressure variability as predictors of incident cardiovascular events in patients with hypertension", Am J Hypertens, 25, pp.962~968 (2012)
- Kawai T, "The impact of visit-to-visit variability in blood pressure on renal function", Hypertens Res, 35, pp.239~243 (2012)
- Niiranen TJ, "Office, home, and ambulatory blood pressures as predictors of cardiovascular risk", Hypertension, 64, pp.281~286 (2014)
- Bliziotis IA, "Home versus ambulatory and office blood pressure in predicting target organ damage in hypertension : a systematic review and meta-analysis", J Hypertens, 30, pp.1289~1299 (2012)
- Gaborieau V, "Ambulatory blood pressure monitoring versus self-measurement of blood pressure at home : correlation with target organ damage", J Hypertens, 26, pp.1919~1927 (2008)
- Asayama K, "Nocturnal blood pressure measured by home devices : evidence and perspective for clinical application", J Hypertens, 37, pp.905~916 (2019)
- Kollias A, "Association of night-time home blood pressure with night-time ambulatory blood pressure and targetorgan damage : a systematic review and meta-analysis", J Hypertens, 35, pp.442~452 (2017)
- Kario K, "Nighttime blood pressure measured by home blood pressure monitoring as an independent predictor of cardiovascular events in general practice", Hypertension, 73, pp.1240~1248 (2019)
- Mauck GW, "The meaning of the point of maximum oscillations in cuffpressure in the indirect measurement of blood pressure–part ii", J Biomech Eng, 102, pp.28~33 (1980)
- Babbs CF, "Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical model", Biomed Eng Online, 11, pp.56~ (2012)
- Jeon G, "A Simulation for Estimation of the Blood Pressure using Arterial Pressure-volume Model", Int J Med Health Sci, 1(6), pp.419~424 (2007)
- O’Brien E, "Accuracy of the Novacor DIASYS 200 determined by the British Hypertension Society protocol", J Hypertens, 9, pp.569~570 (1991)
- Beime B, "Validation protocols for blood pressure-measuring devices : status quo and development needs", Blood Press Monit, 21, pp.1~8 (2016)
- Imai Y, "The Japanese Society of Hypertension Guidelines for self-monitoring of blood pressure at home(second edition)", Hypertens Res, 35, pp.777~795 (2012)
- Muntner P, "Measurement of blood pressure in humans : a scientific statement from the American Heart Association", Hypertension, 73, pp.e35~e66 (2019)
- O’Brien E, "European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement", J Hypertens, 21, pp.821~848 (2003)
- O’Brien E, "European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults", Blood Press Monit, 15, pp.23~38 (2010)
- O’Brien E, "An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devices", J Hypertens, 11, pp.677~679 (1993)
- Stergiou GS, "A universal standard for the validation of blood pressure measuring devices : Association for the Advancement of Medical Instrumentation", European Society of Hypertension, ESH, pp.ISO)Collaboration Statement, Hypertension[DOI]
- Stergiou GS, "Validation protocols for blood pressure measuring devices in the 21st century", J Clin Hypertens(Greenwich), 20, pp.1096~1099 (2018)
- Kario K, "Home blood pressure and cardiovascular outcomes in patients during antihypertensive therapy : primary results of HONEST, a large-scale prospective, real-world observational study", Hypertension, 64, pp.989~996 (2014)
- Ishag Adam, "Red cell distribution width and preeclampsia: a systematic review and meta-analysis", Clinical Hypertension, 25(4), pp.16~23 (2019), 대한고혈압학회[DOI]
- Kwang-Il Kim, "2018 Korean society of hypertension guidelines for the management of hypertension: part III-hypertension in special situations", Clinical Hypertension, 25(4), pp.75~88 (2019), 대한고혈압학회[DOI]
- Hae-Young Lee, "2018 Korean Society of Hypertension Guidelines for the management of hypertension: part II-diagnosis and treatment of hypertension", Clinical Hypertension, 25(4), pp.51~74 (2019), 대한고혈압학회[DOI]
- Umemura S, "The Japanese Society of Hypertension Guidelines for the Management of Hypertension(JSH 2019)", Hypertens Res, 42, pp.1235~1481 (2019)
- Whelton PK, "2017 ACC", AHA, ABC, pp.ACPM, AGS[DOI]
- Williams B, "2018 ESC", ESH Guidelines for the management of arterial hypertension, 2018, pp.39, 3021~3104
- Reboussin DM, "Systematic review for the 2017 ACC", AHA, ABC, pp.ACPM, AGS[DOI]
- Williams B, "2018 ESC", ESH Guidelines for the management of arterial hypertension : The Task Force for the management of arterial hypertension of the European Society of Cardiology and the European Society of Hypertension : The Task Force for the management of arterial hypertension of the European Society of Cardiology and the European Society of Hypertension, 2018, pp.36, 1953~2041
- Mancia G, "Long-term risk of mortality associated with selective and combined elevation in office, home, and ambulatory blood pressure", Hypertension, 47, pp.846~853 (2006)
- Fukunaga H, "Cost-effectiveness of the introduction of home blood pressure measurement in patients with office hypertension", J Hypertens, 26, pp.685~690 (2008)
- Verberk WJ, "Self-measurement of blood pressure at home reduces the need for antihypertensive drugs : a randomized, controlled trial", Hypertension, 50, pp.1019~1025 (2007)
- Franklin SS, "White-coat hypertension : new insights from recent studies", Hypertension, 62, pp.982~987 (2013)
- Martin CA, "White-coat hypertension", Clin Exp Pharmacol Physiol, 41, pp.22~29 (2014)
- 신진호, "Discordance between ambulatory versus clinic blood pressure according to global cardiovascular risk group", The Korean Journal of Internal Medicine, 30(5), pp.610~619 (2015), 대한내과학회[DOI]
- Franklin SS, "Significance of white-coat hypertension in older persons with isolated systolic hypertension : a meta-analysis using the International Database on Ambulatory Blood Pressure Monitoring in Relation to Cardiovascular Outcomes population", Hypertension, 59, pp.564~571 (2012)
- Mancia G, "Long-term risk of sustained hypertension in white-coat or masked hypertension", Hypertension, 54, pp.226~232 (2009)
- Huang Y, "White-coat hypertension is a risk factor for cardiovascular diseases and total mortality", J Hypertens, 35, pp.677~688 (2017)
- Cesario V, "Epidemiological impact and clinical consequences of masked hypertension : a narrative review", High Blood Press Cardiovasc Prev, 27, pp.195~201 (2020)
- Landsbergis PA, "Working conditions and masked hypertension", High Blood Press Cardiovasc Prev, 20, pp.69~76 (2013)
- Stergiou GS, "Prognosis of white-coat and masked hypertension : International Database of HOme blood pressure in relation to Cardiovascular Outcome", Hypertension, 63, pp.675~682 (2014)
- Dolan E, "Current approach to masked hypertension : from diagnosis to clinical management", Clin Exp Pharmacol Physiol, 44, pp.1272~1278 (2017)
- Palatini P, "How should we manage a patient with masked hypertension?", High Blood Press Cardiovasc Prev, 22, pp.11~16 (2015)
- Tientcheu D, "Target organ complications and cardiovascular events associated with masked hypertension and white-coat hypertension : analysis from the Dallas Heart Study", J Am Coll Cardiol, 66, pp.2159~2169 (2015)
- Banegas JR, "Relationship between clinic and ambulatory blood-pressure measurements and mortality", N Engl J Med, 378, pp.1509~1520 (2018)
- Pierdomenico SD, "Prognostic value of masked uncontrolled hypertension", Hypertension, 72, pp.862~869 (2018)
- Asayama K, "Setting thresholds to varying blood pressure monitoring intervals differentially affects risk estimates associated with white-coat and masked hypertension in the population", Hypertension, 64, pp.935~942 (2014)
- Parati G, "European Society of Hypertension practice guidelines for home blood pressure monitoring", J Hum Hypertens, 24, pp.779~785 (2010)
- Ward AM, "Home measurement of blood pressure and cardiovascular disease : systematic review and metaanalysis of prospective studies", J Hypertens, 30, pp.449~456 (2012)
- Shimbo D, "Self-measured blood pressure monitoring at home : a joint policy statement from the American Heart Association and American Medical Association", Circulation, 142, pp.e42~e63 (2020)
- Whelton PK, "2017 ACC", AHA, ABC, pp.ACPM, AGS[DOI]
- Hansen TW, "Prognostic superiority of daytime ambulatory over conventional blood pressure in four populations : a meta-analysis of 7, 030individuals", J Hypertens, 25, pp.1554~1564 (2007)
- The Korean Society of Hypertension, "Blood Pressure Monitoring Guidelines", The Korean Society of Hypertension, ~ (2007)
- Visseren FLJ, "2021 ESC Guidelines on cardiovascular disease prevention in clinical practice", Eur Heart J, 42(34), pp.3227~3337 (2021)[DOI]
- Cappuccio FP, "Blood pressure control by home monitoring : meta-analysis of randomised trials", BMJ, 329, pp.145~ (2004)
- McManus RJ, "Effect of self-monitoring and medication self-titration on systolic blood pressure in hypertensive patients at high risk of cardiovascular disease : the TASMIN-SR randomized clinical trial", JAMA, 312, pp.799~808 (2014)
- Ogihara T, "The Japanese Society of Hypertension Guidelines for the Management of Hypertension(JSH 2009)", Hypertens Res, 32, pp.3~107 (2009)
- Miguel Camafort, "Role of ambulatory blood pressure monitoring in elderly hypertensive patients", Clinical Hypertension, 28, pp.22~22 (2022), 대한고혈압학회[DOI]
- Imai Y, "Predictive power of screening blood pressure, ambulatory blood pressure and blood pressure measured at home for overall and cardiovascular mortality : a prospective observation in a cohort from Ohasama, northern Japan", Blood Press Monit, 1, pp.251~254 (1996)
- Pickering TG, "Call to action on use and reimbursement for home blood pressure monitoring : a joint scientific statement from the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association", Hypertension, 52, pp.10~29 (2008)
- Asayama K, "Cardiovascular outcomes in the first trial of antihypertensive therapy guided by self-measured home blood pressure", Hypertens Res, 35, pp.1102~1110 (2012)
- Noguchi Y, "Predictive power of home blood pressure and clinic blood pressure in hypertensive patients with impaired glucose metabolism and diabetes", J Hypertens, 31, pp.1593~1602 (2013)
- Yasui D, "Evaluating home blood pressure in treated hypertensives in comparison with the referential value of casual screening of blood pressure : the Ohasama study", Blood Press Monit, 17, pp.89~95 (2012)
- Pagonas N, "Impact of atrial fibrillation on the accuracy of oscillometric blood pressure monitoring", Hypertension, 62, pp.579~584 (2013)
- Xie F, "The impact of atrial fibrillation on accuracy of oscillometric blood pressure measurement : effect of ventricular rate", Hypertens Res, 43, pp.518~524 (2020)
- Bello NA, "Accuracy of blood pressure measurement devices in pregnancy : a systematic review of validation studies", Hypertension, 71, pp.326~335 (2018)
- Kario K, "Nocturnal hypertension : new technology and evidence", Hypertension, 71, pp.997~1009 (2018)
- 2018 Korea media panel survey, "Korea Information Society Development Institute", ~ (2018)
- "Non-invasive sphygmomanometers. Part 2: clinical investigation of intermittent automated measurement type (ISO No. 81060–2:2018)" (2018)[URL]
- Visvanathan BR, "Smart phone based blood pressure indicator", Proceedings of the 4th ACM MobiHoc workshop on pervasive wireless healthcare, pp.19~24 (2014)
- Dey J, "InstaBP : cuff-less blood pressure monitoring on smartphone using single PPG sensor", Annu Int Conf IEEE Eng Med Biol Soc, 2018, pp.5002~5005 (2018)
- Matsumura K, "Cuffless blood pressure estimation using only a smartphone", Sci Rep, 8, pp.7298~ (2018)
- ), "AAMI", 2007
- Luo H, "Smartphone-Based blood pressure measurement using transdermal optical imaging technology", Circ Cardiovasc Imaging, 12, pp.e008857~ (2019)
- 이해영, "Smartphone", smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension, 2021, pp.27(2), 37~44[DOI]
- Kim KI, "Real world home blood pressure variability in over 56, 000 individuals with nearly 17 million measurements", Am J Hypertens, 31, pp.566~573 (2018)
