본문 바로가기
KERD
논문KCI 등재

Diagnosis of Rotator Cuff Tears with Non-Arthrographic MR Imaging: 3D Fat-Suppressed Isotropic Intermediate-Weighted Turbo Spin-Echo Sequence versus Conventional 2D Sequences at 3T

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: To assess the diagnostic performance in detecting rotator cuff tears at 3T of non-arthrographic shoulder magnetic resonance imaging (MRI) using 3D isotropic turbo spin-echo (TSE-SPACE) sequence as compared with 2D sequences. Materials and Methods: Seventy-four patients who were arthroscopically confirmed to have underwent non-arthrographic shoulder MRI with 2D sequences and TSESPACE were included. Three independent readers retrospectively scored supraspinatus and infraspinatus tendon (SST-IST) and subscapularis tendon (SCT) tears on 2D sequences and TSE-SPACE. Results: The mean sensitivity, specificity, and accuracy of the three readers were 95%, 100%, and 95% on TSE-SPACE and 99%, 93%, and 98% on 2D sequences for detecting SST-IST tears, respectively, whereas those were 87%, 49%, and 68% on TSESPACE and 88%, 66%, and 77% on 2D sequences for detecting SCT tears, respectively. There was no statistical difference between the two sequences, except for in the specificity of one reader for detecting SCT tears. The mean AUCs of the three readers on TSE-SPACE and 2D sequences were 0.96 and 0.98 for detecting SST-IST tears, respectively, which were not significantly different, while those were 0.71 and 0.82 for detecting SCT tears, respectively, which were significantly different (P < 0.05). Conclusion: TSE-SPACE may have accuracy and reliability comparable to conventional 2D sequences for SST-IST tears at non-arthrographic 3T shoulder MRI, whereas TSE-SPACE was less reliable than conventional 2D sequences for detecting SCT tears.

Abstract

Purpose: To assess the diagnostic performance in detecting rotator cuff tears at 3T of non-arthrographic shoulder magnetic resonance imaging (MRI) using 3D isotropic turbo spin-echo (TSE-SPACE) sequence as compared with 2D sequences. Materials and Methods: Seventy-four patients who were arthroscopically confirmed to have underwent non-arthrographic shoulder MRI with 2D sequences and TSESPACE were included. Three independent readers retrospectively scored supraspinatus and infraspinatus tendon (SST-IST) and subscapularis tendon (SCT) tears on 2D sequences and TSE-SPACE. Results: The mean sensitivity, specificity, and accuracy of the three readers were 95%, 100%, and 95% on TSE-SPACE and 99%, 93%, and 98% on 2D sequences for detecting SST-IST tears, respectively, whereas those were 87%, 49%, and 68% on TSESPACE and 88%, 66%, and 77% on 2D sequences for detecting SCT tears, respectively. There was no statistical difference between the two sequences, except for in the specificity of one reader for detecting SCT tears. The mean AUCs of the three readers on TSE-SPACE and 2D sequences were 0.96 and 0.98 for detecting SST-IST tears, respectively, which were not significantly different, while those were 0.71 and 0.82 for detecting SCT tears, respectively, which were significantly different (P < 0.05). Conclusion: TSE-SPACE may have accuracy and reliability comparable to conventional 2D sequences for SST-IST tears at non-arthrographic 3T shoulder MRI, whereas TSE-SPACE was less reliable than conventional 2D sequences for detecting SCT tears.

참고문헌 (29)

  1. de Jesus JO, "Accuracy of MRI, MR arthrography, and ultrasound in the diagnosis of rotator cuff tears: a meta-analysis", AJR Am J Roentgenol, 192, pp.1701~1707 (2009)
  2. Shapiro L, "Magnetic resonance imaging of the knee: optimizing 3 Tesla imaging", Semin Roentgenol, 45, pp.238~249 (2010)
  3. Gold GE, "Musculoskeletal MRI at 3.0 T: initial clinical experience", AJR Am J Roentgenol, 183, pp.1479~1486 (2004)
  4. Steinbach LS, "Special focus session. MR arthrography", Radiographics, 22, pp.1223~1246 (2002)
  5. Jung JY, "Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences", Skeletal Radiol, 41, pp.1401~1410 (2012)
  6. Jung JY, "SLAP tears:diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences", Eur Radiol, 23, pp.487~495 (2013)
  7. Jung JY, "Three-dimensional isotropic shoulder MR arthrography:comparison with two-dimensional MR arthrography for the diagnosis of labral lesions at 3.0 T", Radiology, 250, pp.498~505 (2009)
  8. Magee T., "Can isotropic fast gradient echo imaging be substituted for conventional T1 weighted sequences in shoulder MR arthrography at 3 Tesla?", J Magn Reson Imaging, 26, pp.118~122 (2007)
  9. 이지현, "Comparison of Three-Dimensional Isotropic and Two-Dimensional Conventional Indirect MR Arthrography for the Diagnosis of Rotator Cuff Tears", Korean Journal of Radiology, 15(6), pp.771~780 (2014), 대한영상의학회[DOI]
  10. Park SY, "Comparison of three-dimensional isotropic and conventional MR arthrography with respect to the diagnosis of rotator cuff and labral lesions: focus on isotropic fat-suppressed proton density and VIBE sequences", Clin Radiol, 69, pp.e173~e182 (2014)
  11. Choo HJ, "Comparison of three-dimensional isotropic T1-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography of the shoulder", Radiology, 262, pp.921~931 (2012)
  12. Kijowski R, "Evaluation of the menisci of the knee joint using three-dimensional isotropic resolution fast spin-echo imaging: diagnostic performance in 250 patients with surgical correlation", Skeletal Radiol, 41, pp.169~178 (2012)
  13. Kijowski R, "Knee joint:comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging--diagnostic performance compared with that of conventional MR imaging at 3.0 T", Radiology, 252, pp.486~495 (2009)
  14. Notohamiprodjo M, "MRI of the knee at 3T: first clinical results with an isotropic PDfsweighted 3D-TSE-sequence", Invest Radiol, 44, pp.585~597 (2009)
  15. Notohamiprodjo M, "3D-MRI of the ankle with optimized 3D-SPACE", Invest Radiol, 47, pp.231~239 (2012)
  16. Ristow O, "Isotropic 3D fast spinecho imaging versus standard 2D imaging at 3.0 T of the knee--image quality and diagnostic performance", Eur Radiol, 19, pp.1263~1272 (2009)
  17. Yao L, "Isotropic 3D fast spinecho with proton-density-like contrast: a comprehensive approach to musculoskeletal MRI", AJR Am J Roentgenol, 188, pp.W199~W201 (2007)
  18. Altman DG., "Practical statistics for medical research", pp.404~409 (1991), Chapman & Hall
  19. Oh DK, "Comparison of indirect isotropic MR arthrography and conventional MR arthrography of labral lesions and rotator cuff tears: a prospective study", AJR Am J Roentgenol, 192, pp.473~479 (2009)
  20. Park HJ, "Evaluation of shoulder pathology: three-dimensional enhanced T1 high-resolution isotropic volume excitation MR vs two-dimensional fast spin echo T2 fat saturation MR", Br J Radiol, 88, pp.20140147~ (2015)
  21. Stevens KJ, "Ankle: isotropic MR imaging with 3D-FSE-cube--initial experience in healthy volunteers", Radiology, 249, pp.1026~1033 (2008)
  22. Van Dyck P, "Diagnostic performance of 3D SPACE for comprehensive knee joint assessment at 3 T", Insights Imaging, 3, pp.603~610 (2012)
  23. Koo SS, "Subscapularis tendon tears:identifying mid to distal footprint disruptions", Arthroscopy, 26, pp.1130~1134 (2010)
  24. David TS, "Arthroscopic visualization of subscapularis tendon lesions", Orthopedics, 32 (2009)
  25. Magee T, "3.0-T MRI of the supraspinatus tendon", AJR Am J Roentgenol, 187, pp.881~886 (2006)
  26. Jung JY, "Comparison study of indirect MR arthrography and direct MR arthrography of the shoulder", Skeletal Radiol, 38, pp.659~667 (2009)
  27. Pfirrmann CW, "Subscapularis tendon tears: detection and grading at MR arthrography", Radiology, 213, pp.709~714 (1999)
  28. Gyftopoulos S, "Correlation of MRI with arthroscopy for the evaluation of the subscapularis tendon: a musculoskeletal division's experience", Skeletal Radiol, 42, pp.1269~1275 (2013)
  29. Jung JY, "Diagnostic performance of MR arthrography with anterior trans-subscapularis versus posterior injection approach for subscapularis tendon tears at 3.0T", Eur Radiol, 27, pp.1303~1311 (2017)

관련 논문AI추천

Fast Imaging of Shoulder MR Arthrography With Compressed Sensing Accelerated Isovolumetric 3D-THRIVE Sequence: Comparing One Isovolumetric Scan With Multiplanar Reconstruction and Three Conventional MR Images송호택, 이영한, Jiwoo Park, Joohee Lee, Youngho Won대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2024 · 제28권 제1호고식적 견관절 자기공명영상에 추가적인 사각시상면 영상 이용 시극상건 손상 검출 진단능 차이에 대한 고찰김지희, 김현주, 장윤우, 차장규, 최득린, 홍성숙, 황정화대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2014 · 제18권 제2호Quantitative T2 Mapping of Articular Cartilage of the Glenohumeral Joint at 3.0T in Rotator Cuff Disease Patients: the Evaluation of Degenerative Change of Cartilage고수연, 이경렬, 최국명대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2019 · 제23권 제3호Fatty Degeneration and Atrophy of Rotator Cuffs: Comparison of Immediate Postoperative MRI with Preoperative MRI김수진, 박진아, 신수미, 유자연, 채지원대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2016 · 제20권 제4호Muscle Functional MRI of Exercise-Induced Rotator Cuff MusclesAtsushi Nishiyama, Noriyuki Tawara대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2021 · 제25권 제1호Three-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI한석, 김형식, 박진오, 서진석, 이영한, 정수윤, 조희우연세대학교의과대학 · Yonsei Medical Journal2017 · 제58권 제6호

이 간행물의 다른 논문 (10건)