Purpose: To evaluate the diagnostic performance of three-dimensional fast spin-echo (3D FSE-Cube) without fat suppression (NFS) for detecting knee lesions, using comparison to 3D FSE-Cube with fat suppression (FS). Materials and Methods: One hundred twenty-four patients who underwent 1.5T knee magnetic resonance imaging (MRI) scans and 25 subsequent arthroscopic surgeries were retrospectively reviewed. Using arthroscopic results and two-dimensional images as reference standards, diagnostic performances of 3D FSE-Cube-NFS and FS imaging about lesions of ligament, meniscus, subchondralbone marrow edema (BME), and cartilage were compared. Scan parameters of 3D FSE-Cube imaging were previously optimized by a porcine knee phantom. Results: No significant differences were observed between detection rates of NFS and FS imaging for detecting lesions of meniscusand cartilage (p>0.05). However, NFS imaging had lower sensitivity for detection of medial collateral ligament (MCL) tears, and lower sensitivity and specificity for detection of BME lesions, compared to FS imaging (p<0.05). Conclusion: 3D FSE-Cube-NFS imaging showed similar diagnostic performance for detecting lesions of meniscus or cartilage compared to FS imaging, unlike MCL or BME lesions.
Abstract
Purpose: To evaluate the diagnostic performance of three-dimensional fast spin-echo (3D FSE-Cube) without fat suppression (NFS) for detecting knee lesions, using comparison to 3D FSE-Cube with fat suppression (FS). Materials and Methods: One hundred twenty-four patients who underwent 1.5T knee magnetic resonance imaging (MRI) scans and 25 subsequent arthroscopic surgeries were retrospectively reviewed. Using arthroscopic results and two-dimensional images as reference standards, diagnostic performances of 3D FSE-Cube-NFS and FS imaging about lesions of ligament, meniscus, subchondralbone marrow edema (BME), and cartilage were compared. Scan parameters of 3D FSE-Cube imaging were previously optimized by a porcine knee phantom. Results: No significant differences were observed between detection rates of NFS and FS imaging for detecting lesions of meniscusand cartilage (p>0.05). However, NFS imaging had lower sensitivity for detection of medial collateral ligament (MCL) tears, and lower sensitivity and specificity for detection of BME lesions, compared to FS imaging (p<0.05). Conclusion: 3D FSE-Cube-NFS imaging showed similar diagnostic performance for detecting lesions of meniscus or cartilage compared to FS imaging, unlike MCL or BME lesions.
참고문헌 (26)
- Mackenzie R, "Magnetic resonance imaging of the knee: assessment of effectiveness", Clin Radiol, 51, pp.245~250 (1996)
- Gold GE, "Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience", AJR Am J Roentgenol, 188, pp.1287~1293 (2007)
- Kijowski R, "Clinical usefulness of adding 3D cartilage imaging sequences to a routine knee MR protocol", AJR Am J Roentgenol, 196, pp.159~167 (2011)
- Kijowski R, "Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging--diagnostic performance compared with that of conventional MR imaging at 3.0 T", Radiology, 252, pp.486~495 (2009)
- Jung JY, "Meniscal tear configurations:categorization with 3D isotropic turbo spin-echo MRI compared with conventional MRI at 3 T", AJR Am J Roentgenol, 198, pp.W173~W180 (2012)
- Jung JY, "Knee derangements:comparison of isotropic 3D fast spin-echo, isotropic 3D balanced fast field-echo, and conventional 2D fast spin-echo MR imaging", Radiology, 268, pp.802~813 (2013)
- Jung JY, "Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences", Radiology, 253, pp.780~787 (2009)
- Lim D, "Clinical value of fat-suppressed 3D volume isotropic spin-echo (VISTA) sequence compared to 2D sequence in evaluating internal structures of the knee", Acta Radiol, 57, pp.66~73 (2016)
- Ai T, "Diagnostic performance of CUBE MRI sequences of the knee compared with conventional MRI", Clin Radiol, 67, pp.e58~e63 (2012)
- Kijowski R, "Evaluation of the menisci of the knee joint using three-dimensional isotropic resolution fast spin-echo imaging: diagnostic performance in 250 patients with surgical correlation", Skeletal Radiol, 41, pp.169~178 (2012)
- Ristow O, "Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee--image quality and diagnostic performance", Eur Radiol, 19, pp.1263~1272 (2009)
- Duc SR, "Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: preliminary study", Radiology, 246, pp.526~535 (2008)
- Lim D, "Fat-suppressed volume isotropic turbo spin echo acquisition (VISTA) MR imaging in evaluating radial and root tears of the meniscus: focusing on readerdefined axial reconstruction", Eur J Radiol, 82, pp.2296~2302 (2013)
- Delfaut EM, "Fat suppression in MR imaging: techniques and pitfalls", Radiographics, 19, pp.373~382 (1999)
- 조경은, "Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression", Investigative Magnetic Resonance Imaging, 17(2), pp.110~122 (2013), 대한자기공명의과학회[DOI]
- Schäfer FK, "Value of fat-suppressed proton-density-weighted turbo spin-echo sequences in detecting meniscal lesions: comparison with arthroscopy", Acta Radiol, 47, pp.385~390 (2006)
- Lee JH, "Diagnosis of internal derangement of the knee: volume isotropic turbo spin-echo acquisition MRI with fat suppression versus without fat suppression", AJR Am J Roentgenol, 208, pp.1304~1311 (2017)
- Lee SY, "Proton density-weighted MR imaging of the knee: fat suppression versus without fat suppression", Skeletal Radiol, 40, pp.189~195 (2011)
- Li CQ, "Optimizing isotropic three-dimensional fast spin-echo methods for imaging the knee", J Magn Reson Imaging, 39, pp.1417~1425 (2014)
- De Smet AA, "MR diagnosis of meniscal tears of the knee: importance of high signal in the meniscus that extends to the surface", AJR Am J Roentgenol, 161, pp.101~107 (1993)
- De Smet AA, "MR diagnosis of meniscal tears: analysis of causes of errors", AJR Am J Roentgenol, 163, pp.1419~1423 (1994)
- Bredella MA, "Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients", AJR Am J Roentgenol, 172, pp.1073~1080 (1999)
- Potter HG, "Magnetic resonance imaging of articular cartilage in the knee. An evaluation with use of fast-spin-echo imaging", J Bone Joint Surg Am, 80, pp.1276~1284 (1998)
- Sonin AH, "Grading articular cartilage of the knee using fast spin-echo proton density-weighted MR imaging without fat suppression", AJR Am J Roentgenol, 179, pp.1159~1166 (2002)
- Noyes FR, "A system for grading articular cartilage lesions at arthroscopy", Am J Sports Med, 17, pp.505~513 (1989)
- Seigel DG, "Acceptable values of kappa for comparison of two groups", Am J Epidemiol, 135, pp.571~578 (1992)