Fast Imaging of Shoulder MR Arthrography With Compressed Sensing Accelerated Isovolumetric 3D-THRIVE Sequence: Comparing One Isovolumetric Scan With Multiplanar Reconstruction and Three Conventional MR Images
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: This study compared 3D-T1 high resolution isovolumetric examination (3DTHRIVE) multiplanar reconstruction (MPR) imaging of shoulder magnetic resonance arthrography (MRA) with conventional MR images and validated the diagnostic agreements of isovolumetric MRA with and without compressed sensing (CS). Materials and Methods: Seventy-three patients who underwent shoulder MRA, including image sets of conventional 2D fast spin echo (FSE) sequences and isotropic 3D-THRIVE sequences with and without CS, were evaluated. The CS acceleration factor was set to 1.5. In the first session, MPR images on the 3D-THRIVE sequence with CS were analyzed using current standard 2D FSE sequences in the axial, oblique-coronal, and oblique-sagittal planes. In the second session, 3D-THRIVE sequences with and without CS were compared with respect to image quality and degree of artifacts. Overall image quality scores and artifacts for conventional 2D images and 3D-THRIVE MPR with CS were analyzed using a paired t-test. The diagnostic agreement for pathological lesions of the shoulder in 3DTHRIVE with and without CS was evaluated using intraclass correlation coefficients. Results: CS in the isotropic 3D-THRIVE showed a reduction in scanning time from 104 s (non-CS) to 81 s (CS). The diagnostic agreement between 2D FSE and 3D-THRIVE for shoulder tendon pathologies was excellent for subscapularis, supraspinatus, infraspinatus, and biceps tendons. The inter-rater agreements were excellent, and CS-3D-THRIVE demonstrated excellent diagnostic agreement for certain tendon pathologies compared with 3D-THRIVE without CS. Conclusion: CS-accelerated isotropic 3D-THRIVE shoulder MRA can provide diagnostically acceptable images of tendon pathology with a reduced scan time. Shoulder MRI using 3D-THRIVE with CS may replace standard 2D FSE sequences in patients who require rapid imaging.
Abstract
Purpose: This study compared 3D-T1 high resolution isovolumetric examination (3DTHRIVE) multiplanar reconstruction (MPR) imaging of shoulder magnetic resonance arthrography (MRA) with conventional MR images and validated the diagnostic agreements of isovolumetric MRA with and without compressed sensing (CS). Materials and Methods: Seventy-three patients who underwent shoulder MRA, including image sets of conventional 2D fast spin echo (FSE) sequences and isotropic 3D-THRIVE sequences with and without CS, were evaluated. The CS acceleration factor was set to 1.5. In the first session, MPR images on the 3D-THRIVE sequence with CS were analyzed using current standard 2D FSE sequences in the axial, oblique-coronal, and oblique-sagittal planes. In the second session, 3D-THRIVE sequences with and without CS were compared with respect to image quality and degree of artifacts. Overall image quality scores and artifacts for conventional 2D images and 3D-THRIVE MPR with CS were analyzed using a paired t-test. The diagnostic agreement for pathological lesions of the shoulder in 3DTHRIVE with and without CS was evaluated using intraclass correlation coefficients. Results: CS in the isotropic 3D-THRIVE showed a reduction in scanning time from 104 s (non-CS) to 81 s (CS). The diagnostic agreement between 2D FSE and 3D-THRIVE for shoulder tendon pathologies was excellent for subscapularis, supraspinatus, infraspinatus, and biceps tendons. The inter-rater agreements were excellent, and CS-3D-THRIVE demonstrated excellent diagnostic agreement for certain tendon pathologies compared with 3D-THRIVE without CS. Conclusion: CS-accelerated isotropic 3D-THRIVE shoulder MRA can provide diagnostically acceptable images of tendon pathology with a reduced scan time. Shoulder MRI using 3D-THRIVE with CS may replace standard 2D FSE sequences in patients who require rapid imaging.
참고문헌 (19)
- Magee T, "3. 0-T MRI of the supraspinatus tendon", AJR Am J Roentgenol, 187, pp.881~886 (2006)
- Magee TH, "Sensitivity and specificity in detection of labral tears with 3. 0-T MRI of the shoulder", AJR Am J Roentgenol, 187, pp.1448~1452 (2006)
- Gusmer PB, "Labral injuries : accuracy of detection with unenhanced MR imaging of the shoulder", Radiology, 200, pp.519~524 (1996)
- Alaia EF, "Shoulder MR imaging and MR arthrography techniques : new advances", Magn Reson Imaging Clin N Am, 28, pp.153~163 (2020)
- Magee T, "3-T MRI of the shoulder : is MR arthrography necessary?", AJR Am J Roentgenol, 192, pp.86~92 (2009)
- Blanchard TK, "Magnetic resonance imaging or arthrography of the shoulder : which do patients prefer?", Br J Radiol, 70, pp.786~790 (1997)
- Saupe N, "Pain and other side effects after MR arthrography : prospective evaluation in 1085 patients", Radiology, 250, pp.830~838 (2009)
- Fox MG, "Shoulder MR arthrography : intraarticular anesthetic reduces periprocedural pain and major motion artifacts but does not decrease imaging time", Radiology, 262, pp.576~583 (2012)
- Jung JY, "Three-dimensional isotropic shoulder MR arthrography : comparison with two-dimensional MR arthrography for the diagnosis of labral lesions at 3. 0 T", Radiology, 250, pp.498~505 (2009)
- Lee SH, "Diagnostic performance of shoulder magnetic resonance arthrography for labral tears having surgery as reference : comparison of high-resolution isotropic 3D sequence(THRIVE)with standard protocol", Radiol Med, 123, pp.620~630 (2018)
- Sodickson DK, "Simultaneous acquisition of spatial harmonics(SMASH) : fast imaging with radiofrequency coil arrays", Magn Reson Med, 38, pp.591~603 (1997)
- Pruessmann KP, "SENSE : sensitivity encoding for fast MRI", Magn Reson Med, 42, pp.952~962 (1999)
- Griswold MA, "Generalized autocalibrating partially parallel acquisitions(GRAPPA)", Magn Reson Med, 47, pp.1202~1210 (2002)
- Donoho DL, "Compressed sensing", IEEE Trans Inf Theory, 52, pp.1289~1306 (2006)
- Lustig M, "Compressed sensing MRI", IEEE Signal Process Mag, 25, pp.72~82 (2008)
- Lustig M, "Sparse MRI : the application of compressed sensing for rapid MR imaging", Magn Reson Med, 58, pp.1182~1195 (2007)
- Jaspan ON, "Compressed sensing MRI : a review of the clinical literature", Br J Radiol, 88, pp.20150487~ (2015)
- Lee SH, "Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing", Magn Reson Imaging, 42, pp.152~157 (2017)
- Baek SD, "Artificial intelligence and deep learning in musculoskeletal magnetic resonance imaging", Investig Magn Reson Imaging, 27, pp.67~74 (2023)
