본문 바로가기
KERD
논문KCI 등재

Quantification of Gadolinium Concentration Using GRE and UTE Sequences

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: To compare different MR sequences for quantification of gadolinium concentration. Materials and Methods: Gadolinium contrast agents were diluted into 36 different concentrations. They were scanned using gradient echo (GRE) and ultrashort echo time (UTE) and R1, R2* and phase values were estimated from collected data. For analysis, ROI masks were made for each concentration and then ROI value was measured by mean and standard deviation from the estimated quantitative maps. Correlation analysis was performed and correlation coefficient was calculated. Results: Using GRE sequence, R1 showed a strong linear correlation at concentrations of 10 mM or less, and R2* showed a strong linear correlation between 10 to 100 mM. The phase of GRE generally exhibited a negative linear relationship for concentrations of 100 mM or less. In the case of UTE, the phase had a strong negative linear relationship at concentrations 100 mM or above. Conclusion: R1, which was calculated by conventional GRE, showed a high performance of quantification for lower concentrations, with a correlation coefficient of 0.966 (10 mM or less). R2* showed stronger potential for higher concentrations with a correlation coefficient of 0.984 (10 to 100 mM), and UTE phase showed potential for even higher concentrations with a correlation coefficient of 0.992 (100 mM or above).

Abstract

Purpose: To compare different MR sequences for quantification of gadolinium concentration. Materials and Methods: Gadolinium contrast agents were diluted into 36 different concentrations. They were scanned using gradient echo (GRE) and ultrashort echo time (UTE) and R1, R2* and phase values were estimated from collected data. For analysis, ROI masks were made for each concentration and then ROI value was measured by mean and standard deviation from the estimated quantitative maps. Correlation analysis was performed and correlation coefficient was calculated. Results: Using GRE sequence, R1 showed a strong linear correlation at concentrations of 10 mM or less, and R2* showed a strong linear correlation between 10 to 100 mM. The phase of GRE generally exhibited a negative linear relationship for concentrations of 100 mM or less. In the case of UTE, the phase had a strong negative linear relationship at concentrations 100 mM or above. Conclusion: R1, which was calculated by conventional GRE, showed a high performance of quantification for lower concentrations, with a correlation coefficient of 0.966 (10 mM or less). R2* showed stronger potential for higher concentrations with a correlation coefficient of 0.984 (10 to 100 mM), and UTE phase showed potential for even higher concentrations with a correlation coefficient of 0.992 (100 mM or above).

참고문헌 (11)

  1. Padhani AR, "Dynamic contrast-enhanced MRI studies in oncology with an emphasis on quantification, validation and human studies", Clin Radiol, 56, pp.607~620 (2001)
  2. Kuo PH, "Gadoliniumbased MR contrast agents and nephrogenic systemic fibrosis", Radiology, 242, pp.647~649 (2007)
  3. Kanda T, "Gadolinium-based contrast agent accumulates in the brain Even in subjects without severe renal dysfunction : evaluation of autopsy brain specimens with inductively coupled plasma mass spectroscopy", Radiology, 276, pp.228~232 (2015)
  4. Caravan P, "Strategies for increasing the sensitivity of gadolinium based MRI contrast agents", Chem Soc Rev, 35, pp.512~523 (2006)
  5. Trattnig S, "Threedimensional delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) for in vivo evaluation of reparative cartilage after matrix-associated autologous chondrocyte transplantation at 3.0T: Preliminary results", J Magn Reson Imaging, 26, pp.974~982 (2007)
  6. Sasaki M, "Enhancement effects and relaxivities of gadolinium-DTPA at 1.5 versus 3Tesla: a phantom study", Magn Reson Med Sci, 4, pp.145~149 (2005)
  7. Robson MD, "Magnetic resonance : an introduction to ultrashort TE(UTE)imaging", J Comput Assist Tomogr, 27, pp.825~846 (2003)
  8. Hittmair K, "Method for the quantitative assessment of contrast agent uptake in dynamic contrast-enhanced MRI", Magn Reson Med, 31, pp.567~571 (1994)
  9. Li W, "Integrated Laplacianbased phase unwrapping and background phase removal for quantitative susceptibility mapping", NMR Biomed, 27, pp.219~227 (2014)
  10. Poselt E, "Relaxivity optimization of a PEGylated iron-oxide-based negative magnetic resonance contrast agent for T(2)-weighted spinecho imaging", ACS Nano, 6, pp.1619~1624 (2012)
  11. Sosnovik DE, "Magnetic nanoparticles for MR imaging: agents, techniques and cardiovascular applications", Basic Res Cardiol, 103, pp.122~130 (2008)

관련 논문AI추천

3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 –팬텀 연구유승만, 이석준대한방사선과학회 · Journal of Radiological Science and Technology2015 · 제38권 제3호T2 이완시간의 정량적 평가에 있어서 Maximum TE의 설정 범위에 대한 연구: 팬텀연구김성호, 박진서대한방사선과학회 · Journal of Radiological Science and Technology2018 · 제41권 제1호A Systematic Study on MR Contrast Agents for Constructing Specific Relaxation Times안상두, 이철현, 조장근, 조재현한국자기공명학회 · Journal of the Korean Magnetic Resonance Society2010 · 제14권 제1호Generating Motion- and Distortion-Free Local Field Map Using 3D Ultrashort TE MRI: Comparison with T2* Mapping김대홍, 정은희, 한봉수, Bijaya Thapa, Kyle Jeong대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2019 · 제23권 제4호CT 조영제가 MR 조영제의 이완율에 미치는 영향강충환, 권순용, 김성호, 박진서, 정현근대한방사선과학회 · Journal of Radiological Science and Technology2018 · 제41권 제2호Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)- Enhanced MR Imaging of the Liver고명주, 고수연, 김두리, 김봉수, 김승형, 송병철, 이경렬, 이무숙, 이정섭, 최국명대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2017 · 제21권 제2호

이 간행물의 다른 논문 (11건)