Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods: CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in 2π dephasing across a single pixel. Extended phase graph (EPG) simulations were performed to show the signal behaviors of iSSFP, bSSFP, and RF-spoiled gradient echo (SPGR) sequences. In vivo experiments were performed for brain and abdominal imaging at 3T with simultaneous multi-slice (SMS) acceleration factors of 2, 3 and 4 with CAIPI-iSSFP and CAIPI-bSSFP. The image quality was evaluated by measuring the relative contrast-to-noise ratio (CNR) and by qualitatively assessing banding artifact removal in the brain. Results: Banding artifacts were removed using CAIPI-iSSFP compared to CAIPI-bSSFP up to an SMS factor of 4 and 3 on brain and liver imaging, respectively. The relative CNRs between gray and white matter were on average 18% lower in CAIPI-iSSFP compared to that of CAIPI-bSSFP. Conclusion: This study demonstrated that CAIPI-iSSFP provides up to a factor of four acceleration, while minimizing the banding artifacts with up to a 20% decrease in the relative CNR.
Abstract
Purpose: To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods: CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in 2π dephasing across a single pixel. Extended phase graph (EPG) simulations were performed to show the signal behaviors of iSSFP, bSSFP, and RF-spoiled gradient echo (SPGR) sequences. In vivo experiments were performed for brain and abdominal imaging at 3T with simultaneous multi-slice (SMS) acceleration factors of 2, 3 and 4 with CAIPI-iSSFP and CAIPI-bSSFP. The image quality was evaluated by measuring the relative contrast-to-noise ratio (CNR) and by qualitatively assessing banding artifact removal in the brain. Results: Banding artifacts were removed using CAIPI-iSSFP compared to CAIPI-bSSFP up to an SMS factor of 4 and 3 on brain and liver imaging, respectively. The relative CNRs between gray and white matter were on average 18% lower in CAIPI-iSSFP compared to that of CAIPI-bSSFP. Conclusion: This study demonstrated that CAIPI-iSSFP provides up to a factor of four acceleration, while minimizing the banding artifacts with up to a 20% decrease in the relative CNR.
참고문헌 (37)
- Miller KL, "Steady-state MRI : methods for neuroimaging", Imaging Med, 3, pp.93~105 (2011)
- Carr H, "Steady-state free precession in nuclear magnetic resonance", Phys Rev, 112, pp.1693~1701 (1958)
- Bieri O, "Fundamentals of balanced steady state free precession MRI", J Magn Reson Imaging, 38, pp.2~11 (2013)
- Scheffler K, "Principles and applications of balanced SSFP techniques", Eur Radiol, 13, pp.2409~2418 (2003)
- Oppelt A, "FISP : a new fast MRI sequence", Electromedica, 54, pp.15~18 (1986)
- Duerk JL, "Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T", J Magn Reson Imaging, 8, pp.203~208 (1998)
- Pruessmann KP, "SENSE : sensitivity encoding for fast MRI", Magn Reson Med, 42, pp.952~962 (1999)
- Robson PM, "Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions", Magn Reson Med, 60, pp.895~907 (2008)
- Larkman DJ, "Use of multicoil arrays for separation of signal from multiple slices simultaneously excited", J Magn Reson Imaging, 13, pp.313~317 (2001)
- Setsompop K, "Improving diffusion MRI using simultaneous multi-slice echo planar imaging", Neuroimage, 63, pp.569~580 (2012)
- Breuer FA, "Controlled aliasing in parallel imaging results in higher acceleration(CAIPIRINHA)for multi-slice imaging", Magn Reson Med, 53, pp.684~691 (2005)
- Stäb D, "CAIPIRINHA accelerated SSFP imaging", Magn Reson Med, 65, pp.157~164 (2011)
- Haacke EM, "Steadystate free precession imaging in the presence of motion : application for improved visualization of the cerebrospinal fluid", Radiology, 175, pp.545~552 (1990)
- Hargreaves BA, "Rapid gradient-echo imaging", J Magn Reson Imaging, 36, pp.1300~1313 (2012)
- Khajehim M, "A quantitative analysis of fMRI induced phase changes using averaged-BOSS (A-BOSS)", Proceedings of the 23rd Scientific Meeting of International Society for Magnetic Resonance in Medicine, pp.3921~ (2015)
- Shams Z, "Averaged-BOSS: feasibility study and preliminary results", Proceedings of the 22nd Scientific Meeting of International Society for Magnetic Resonance in Medicine, pp.4216~ (2014)
- Zur Y, "Spoiling of transverse magnetization in steady-state sequences", Magn Reson Med, 21, pp.251~263 (1991)
- Crawley AP, "Elimination of transverse coherences in FLASH MRI", Magn Reson Med, 8, pp.248~260 (1988)
- Sekihara K, "Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals", IEEE Trans Med Imaging, 6, pp.157~164 (1987)
- Scheffler IE, "Helix formation by dAT oligomers. I. Hairpin and straight-chain helices", J Mol Biol, 36, pp.291~304 (1968)
- Breuer FA, "Controlled aliasing in volumetric parallel imaging(2D CAIPIRINHA)", Magn Reson Med, 55, pp.549~556 (2006)
- Haacke EM, "Improving MR image quality in the presence of motion by using rephasing gradients", AJR Am J Roentgenol, 148, pp.1251~1258 (1987)
- Axel L, "MR flow imaging by velocitycompensated", uncompensated difference images, 1987, pp.11, 31~34
- Simonetti OP, "Significance of the point of expansion in interpretation of gradient moments and motion sensitivity", J Magn Reson Imaging, 1, pp.569~577 (1991)
- Weigel M, "Extended phase graphs: dephasing, RF pulses, and echoes - pure and simple", J Magn Reson Imaging, 41, pp.266~295 (2015)
- Wansapura JP, "NMR relaxation times in the human brain at 3.0 tesla", J Magn Reson Imaging, 9, pp.531~538 (1999)
- Wang Y, "Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7 T", Neuroimage, 113, pp.279~288 (2015)
- Xiang QS, "Banding artifact removal for bSSFP imaging with an elliptical signal model", Magn Reson Med, 71, pp.927~933 (2014)
- Mikaiel S, "Real-time golden angle radial iSSFP for interventional MRI", Proceedings of the 24th Scientific Meeting of International Society for Magnetic Resonance in Medicine, pp.3579~ (2016)
- Sun K, "Integrated SSFP for functional brain mapping at 7T with reduced susceptibility artifact", J Magn Reson, 276, pp.22~30 (2017)
- Kim MO, "Multislice CAIPIRINHA using view angle tilting technique(CAIPIVAT)", Tomography, 2, pp.43~48 (2016)
- Kim D, "Multi-slice imAGe generation using intra-slice paraLLel imaging and Inter-slice shifting(MAGGULLI)", Phys Med Biol, 61, pp.1692~1704 (2016)
- Bilgic B, "Wave-CAIPI for highly accelerated 3D imaging", Magn Reson Med, 73, pp.2152~2162 (2015)
- Setsompop K, "Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty", Magn Reson Med, 67, pp.1210~1224 (2012)
- Bieri O, "Flow compensation in balanced SSFP sequences", Magn Reson Med, 54, pp.901~907 (2005)
- Wang Y, "Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction", Magn Reson Med, 76, pp.1764~1774 (2016)
- Gagoski BA, "RARE", turbo spin echo imaging with simultaneous multislice wave-CAIPI, 2015, pp.73, 929~938
