본문 바로가기
KERD
논문KCI 등재

Diagnostic Value of Zero Echo Time Magnetic Resonance Imaging for Pediatric Osseous Pathologies

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: This study aimed to determine whether zero echo time magnetic resonance imaging (ZTE-MRI), as an alternative imaging modality, and conventional computed tomography (CT) have similar diagnostic qualities for assessing pediatric osseous pathologies. Materials and Methods: Twenty-six sets of pediatric musculoskeletal CT and MRI scans (15 boys and 11 girls; mean age, 12 ± 4 years; range, 5–23 years) acquired at Seoul National University Children’s Hospital (January 2021 to November 2023) were retrospectively evaluated. CT-like images from ZTE-MRI were generated using grayscale inversion. Two radiologists independently assessed ZTE-MRI image quality (Sanat) on a 5-point scale (1 = nondiagnostic, 5 = excellent) and a comparative scale (–2 = CT greater, 0 = same, 2 = ZTE-MRI greater) for lesion delineation (Scomp). The confidence interval of proportions and intraclass correlation coefficient were calculated to assess inter-rater agreement, and Wilcoxon rank-sum test, Mann–Whitney U test, or paired t-test was used to compare image quality or cortical thickness between the modalities. Results: ZTE-MRI demonstrated diagnostic quality (Sanat ≥ 3) in 85%–96% of the cases, 89%–96% for cortical delineation, 92%–100% for intramedullary cavity (IMC) delineation, and 92% for lesion delineation. Compared with conventional CT, ZTE-MRI showed comparable diagnostic power (Scomp ≥ –1) in 92%–96% of the cases, with Scomp scores indicating no significant difference in lesion delineation (p = 0.53 in reader 1 and p = 0.25 in reader 2). There was a preference for CT over ZTE-MRI in terms of overall image quality and delineation of the cortex and IMC (p < 0.001). Cortical thickness was not significantly different (p = 0.11) between ZTE-MRI and CT. Conclusion: ZTE-MRI demonstrated diagnostic quality comparable to that of CT, particularly in lesion delineation. In addition to the unique information that conventional MRI can provide, ZTE-MRI can provide additional information about osseous structures similar to that provided by CT, which we believe will be valuable in the future.

Abstract

Purpose: This study aimed to determine whether zero echo time magnetic resonance imaging (ZTE-MRI), as an alternative imaging modality, and conventional computed tomography (CT) have similar diagnostic qualities for assessing pediatric osseous pathologies. Materials and Methods: Twenty-six sets of pediatric musculoskeletal CT and MRI scans (15 boys and 11 girls; mean age, 12 ± 4 years; range, 5–23 years) acquired at Seoul National University Children’s Hospital (January 2021 to November 2023) were retrospectively evaluated. CT-like images from ZTE-MRI were generated using grayscale inversion. Two radiologists independently assessed ZTE-MRI image quality (Sanat) on a 5-point scale (1 = nondiagnostic, 5 = excellent) and a comparative scale (–2 = CT greater, 0 = same, 2 = ZTE-MRI greater) for lesion delineation (Scomp). The confidence interval of proportions and intraclass correlation coefficient were calculated to assess inter-rater agreement, and Wilcoxon rank-sum test, Mann–Whitney U test, or paired t-test was used to compare image quality or cortical thickness between the modalities. Results: ZTE-MRI demonstrated diagnostic quality (Sanat ≥ 3) in 85%–96% of the cases, 89%–96% for cortical delineation, 92%–100% for intramedullary cavity (IMC) delineation, and 92% for lesion delineation. Compared with conventional CT, ZTE-MRI showed comparable diagnostic power (Scomp ≥ –1) in 92%–96% of the cases, with Scomp scores indicating no significant difference in lesion delineation (p = 0.53 in reader 1 and p = 0.25 in reader 2). There was a preference for CT over ZTE-MRI in terms of overall image quality and delineation of the cortex and IMC (p < 0.001). Cortical thickness was not significantly different (p = 0.11) between ZTE-MRI and CT. Conclusion: ZTE-MRI demonstrated diagnostic quality comparable to that of CT, particularly in lesion delineation. In addition to the unique information that conventional MRI can provide, ZTE-MRI can provide additional information about osseous structures similar to that provided by CT, which we believe will be valuable in the future.

참고문헌 (23)

  1. Du J, "Assessment of cortical bone with clinical and ultrashort echo time sequences", Magn Reson Med, 70, pp.697~704 (2013)
  2. Wehrli FW, "Quantitative MRI for the assessment of bone structure and function", NMR Biomed, 19, pp.731~764 (2006)
  3. Du J, "Qualitative and quantitative ultrashort echo time(UTE)imaging of cortical bone", J Magn Reson, 207, pp.304~311 (2010)
  4. Weiger M, "MRI with zero echo time", eMagRes, 1, pp.311~322 (2012)
  5. Weiger M, "ZTE imaging in humans", Magn Reson Med, 70, pp.328~332 (2013)
  6. Froidevaux R, "High-resolution short-T2 MRI using a high-performance gradient", Magn Reson Med, 84, pp.1933~1946 (2020)
  7. Sandberg JK, "Zero echo time pediatric musculoskeletal magnetic resonance imaging : initial experience", Pediatr Radiol, 51, pp.2549~2560 (2021)
  8. Koff MF, "Correlation of meniscal T2*with multiphoton microscopy, and change of articular cartilage T2 in an ovine model of meniscal repair", Osteoarthritis Cartilage, 21, pp.1083~1091 (2013)
  9. Bae WC, "Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk", Top Magn Reson Imaging, 21, pp.275~289 (2010)
  10. Chang EY, "Quantitative bicomponent T2* analysis of histologically normal Achilles tendons", Muscles Ligaments Tendons J, 5, pp.58~62 (2015)
  11. Bae K, "Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences : preliminary study", Eur Radiol, 29, pp.2253~2262 (2019)
  12. Beenakker JM, "Silent volumetric multi-contrast 7 tesla MRI of ocular tumors using zero echo time imaging", PLoS One, 14, pp.e0222573~ (2019)
  13. Breighner RE, "Technical developments : zero echo time imaging of the shoulder : enhanced osseous detail by using MR imaging", Radiology, 286, pp.960~966 (2018)
  14. Breighner RE, "Evaluation of osseous morphology of the hip using zero echo time magnetic resonance imaging", Am J Sports Med, 47, pp.3460~3468 (2019)
  15. Lee C, "CT-like MRI using the zero-TE technique for osseous changes of the TMJ", Dentomaxillofac Radiol, 49, pp.20190272~ (2020)
  16. Argentieri EC, "Diagnostic accuracy of zero-echo time MRI for the evaluation of cervical neural foraminal stenosis", Spine(Phila Pa 1976), 43, pp.928~933 (2018)
  17. Cho SB, "Clinical feasibility of zero TE skull MRI in patients with head trauma in comparison with CT : a single-center study", AJNR Am J Neuroradiol, 40, pp.109~115 (2019)
  18. Koo TK, "A guideline of selecting and reporting intraclass correlation coefficients for reliability research", J Chiropr Med, 15, pp.155~163 (2016)
  19. Aydıngöz Ü, "Zero echo time musculoskeletal MRI : technique, optimization, applications, and pitfalls", Radiographics, 42, pp.1398~1414 (2022)
  20. Alibek S, "Acoustic noise reduction in MRI using Silent Scan : an initial experience", Diagn Interv Radiol, 20, pp.360~363 (2014)
  21. Lu A, "Zero TE MRI for craniofacial bone imaging", AJNR Am J Neuroradiol, 40, pp.1562~1566 (2019)
  22. Heindel W, "Artifacts in MR imaging after surgical intervention", J Comput Assist Tomogr, 10, pp.596~599 (1986)
  23. Arena L, "MR imaging artifacts that simulate disease : how to recognize and eliminate them", Radiographics, 15, pp.1373~1394 (1995)

관련 논문AI추천

Development and Evaluation of Deep Learning-Based Automatic Segmentation Model for Skull Zero TE MRI in ChildrenJoon Sung Lee, Jung-Eun Cheon, Seul Bi Lee, Seunghyun Lee, Su-Mi Shin, Yeon Jin Cho, Young Hun Choi, Yun Seok Seo대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2023 · 제27권 제1호Ultrashort Echo Time and Zero Echo Time MRI and Their Applications at High Magnetic Fields: A Literature SurveySoham S. More, Xiaoliang Zhang대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2024 · 제28권 제4호초기의 단순 X선 촬영술 대 자기공명영상: 소아성 대퇴골두 무혈성 괴사증에서 예후 예측성 비교옥인영, 이선진, 정창훈, 조송미, 지원희대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2008 · 제12권 제2호소아 급성 화농성 고관절염 의증 환자에서 자기공명영상의 유용성박수성, 심경보, 이수호대한고관절학회 · Hip and Pelvis2012 · 제24권 제4호LCP 환아에서 골괴사의 평가방법으로 연골하 골절선과 자기공명영상의 비교김동희, 김진원, 나재범, 박미정, 유재욱, 이경규, 정성훈, 조재민, 최호철대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2009 · 제13권 제2호T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques어홍, 김지혜, 유소영, 이정희, 장경미, 정지영대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2007 · 제11권 제2호

이 간행물의 다른 논문 (4건)