본문 바로가기
KERD
논문KCI 등재

휴대용 디지털 압통기의 측정자내 신뢰도 및 측정자간 신뢰도 측정

Measurement of Intrarater Reliability and Interrater Reliability of a Portable Digital Pressure Algometer

2

조회

0

다운로드

4

인용

0

참고문헌

주제분류물리치료학

초록

The purpose of this study was to measure intrarater and interrater reliability of a portable digital pressure algometer. Fifty healthy subjects were recruited for this study. Pressure pain thresholds of splenius capitis, levator scapular, and upper trapezius muscles were measured using by FPK algometer and portable digital pressure algometer. Three trials were done on each subject by two examiners. Intraclass correlation coefficients (ICCs) were used to determine the reliability of each measure. The intrarater reliability of the FPK algometer was good and excellent (ICC .63~.79) and the interrater reliability was poor and good (ICC .15~.57). The intrarater reliability of a portable digital pressure algometer was excellent (ICC .75~.86) and the interrater reliability was poor and good (ICC .35~.61). This result suggests that the intrarater reliability and interrater reliability of a portable digital pressure algometer were better than an FPK algometer.

Abstract

The purpose of this study was to measure intrarater and interrater reliability of a portable digital pressure algometer. Fifty healthy subjects were recruited for this study. Pressure pain thresholds of splenius capitis, levator scapular, and upper trapezius muscles were measured using by FPK algometer and portable digital pressure algometer. Three trials were done on each subject by two examiners. Intraclass correlation coefficients (ICCs) were used to determine the reliability of each measure. The intrarater reliability of the FPK algometer was good and excellent (ICC .63~.79) and the interrater reliability was poor and good (ICC .15~.57). The intrarater reliability of a portable digital pressure algometer was excellent (ICC .75~.86) and the interrater reliability was poor and good (ICC .35~.61). This result suggests that the intrarater reliability and interrater reliability of a portable digital pressure algometer were better than an FPK algometer.

참고문헌 (34)

  1. 송미혜, "휴대용 디지털 압통기의 설계", 전기학회논문지 D권, 52(11), pp.657~661 (2003), 대한전기학회
  2. 이충휘, "물리치료사와 작업치료사를 위한 연구방법론. 2판" (2005), 계축문화사
  3. Andersen JH, "Physical, psychosocial, and individual risk factors for neck", shoulder pain with pressure tenderness in the muscles among workers performing monotonous, repetitive work, 2002, pp.27(6), 660~667
  4. Antonaci F, "Pressure algometry in healthy subjects: Inter-examiner variability", Scand J Rehabil Med, 30(1), pp.3~8 (1998)
  5. Bovim G, "Cervicogenic headache, migraine, and tension-type headache. Pressure-pain threshold measurements", Pain, 51(2), pp.169~173 (1992)
  6. Brennum J, "Measurements of human pressure-pain thresholds on fingers and toes", Pain, 38(2), pp.211~217 (1989)
  7. Brett V, "of an electronic pressure algometer", Int J Osteopath Med, 10(1), pp.24~28 (2007)
  8. Bryan AS, "The diagnosis of reflex sympathetic dystrophy using an algometer", J Bone Joint Surg Br, 73(4), pp.644~646 (1991)
  9. Chesterton L, "Gender differences in pressure pain thresholds in healthy humans", Pain, 101(3), pp.259~266
  10. Chung SC, "Evaluation of pressure pain threshold in head and neck muscles by electronic algometer: Intrarater and interrater reliability", Cranio, 10(1), pp.28~34 (1991)
  11. Clausen T, "The sodium pump keeps us going", Ann N Y Acad Sci, 986, pp.595~602 (2003)
  12. Delaney GA, "Inter- and intra-rater reliability of the pressure threshold meter in measurement of myofascial trigger point sensitivity", Am J Phys Med Rehabil, 72(3), pp.136~139 (1993)
  13. Farasyn A, "Pressure pain thresholds in healthy subjects: Influence of physical activity, history of lower back pain factors and the use of endermology as a placebo-like treatment", Journal of Bodywork and Movement Therapies, 7(1), pp.53~61 (2003)
  14. Fischer A, "Pressure algometry over normal muscles: Standard values, validity, and reproducibility of pressure threshold", Pain, 30(1), pp.115~126 (1987)
  15. Fleiss JL, "Reliability of measurement, Design and Analysis of Clinical Experiments", pp.1~32 (1986), John Wiley & Sons
  16. Granges G, "Pressure pain threshold in pain-free subjects, in patients with chronic regional pain syndromes, and in patients with fibromyalgia syndrome", Arthritis Rheum, 36(5), pp.642~646 (1993)
  17. Incel NA, "Pain pressure threshold values in ankylosing spondylitis", Rheumatol Int, 22(4), pp.148~150 (2002)
  18. Itoh K, "A proposed experimental model of myofascial trigger points in human muscle after slow eccentric exercise", Acupunct Med, 22(1), pp.2~13 (2004)
  19. Jensen K, "Pressure-pain threshold in human temporal region: Evaluation of a new pressure algometer", Pain, 25(3), pp.313~323 (1986)
  20. Kosek E, "A comparison of pressure-pain thresholds in different tissues and body regions. Long-term reliability of pressure", Scand J Rehabil Med, 25(3), pp.117~124 (1993)
  21. Levoska S, "Repeatability of measurement of tenderness in the neck-shoulder region by a dolorimeter and manual palpation", Clin J Pain, 9(4), pp.229~235 (1993)
  22. Maquet D, "Pressure pain thresholds of tender point sites in patients with fibromyalgia and in healthy controls", Eur J Pain, 8(2), pp.111~117 (2004)
  23. McCreary C, "Principal dimensions of the pain experience and psychological disturbance in chronic low back pain patients", Pain, 11(1), pp.85~92 (1981)
  24. Nussbaum EL, "Reliability of clinical pressure-pain algometric measurements obtained on consecutive days", Phys Ther, 78(2), pp.160~169 (1998)
  25. Ohrbach R, "Pressure-pain thresholds in normal muscles: Reliability, measurement effects, and topographic differences", Pain, 37(3), pp.257~263 (1989)
  26. Rolke R, "Deep pain thresholds in the distal limbs of healthy human subjects", Eur J pain, 9(1), pp.39~48 (2005)
  27. Rolke R, "Quantitative sensory testing: A comprehensive protocol for clinical trials", Eur J Pain, 10(1), pp.77~88 (2006)
  28. Shapira SC, "Assessment of pain threshold and pain tolerance in women in labour and in the early post-partum period by pressure algometry", Eur J Anaesthesiol, 12(5), pp.495~499 (1995)
  29. Smania N, "Therapeutic effects of peripheral magnetic stimulation on myofascial pain syndrome", Clin Neurophysiol, 114(2), pp.350~358 (2003)
  30. Vatine JJ, "Electronic pressure algometry of deep pain in healthy volunteers", Arch Phys Med Rehabil, 74(5), pp.526~530 (1993)
  31. Von Korff M, "Assessing global pain severity by self-report in clinical and health services research", Spine, 25(24), pp.3140~3151 (2000)
  32. Ylinen J, "Effect of long-term neck muscle training on pressure pain threshold: A randomized controlled trial", Eur J Pain, 9(6), pp.673~681 (2005)
  33. Ylinen J, "Pressure algometry", Aust J Physiother, 53(3), pp.207~ (2007)
  34. Ylinen J, "Evaluation of repeatability of pressure algometry on the neck muscles for clinical use", Man Ther, 12(2), pp.192~197 (2007)

관련 논문AI추천