COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: K3TM (SybronEndo,Glendora, CA, USA), Mtwo (VDW GmbH, Mu¨nchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile R (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper R (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper R, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper R produced significantly more screw-in effects than any other instruments in the study (p <0.001). K3TM produced significantly more screw-in effects than Mtwo, and ProFile (p < 0.001). There was no significant difference among Mtwo, NRT, and ProFile R (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference. [J Kor Acad Cons Dent 35(4):267-272, 2010]
Abstract
Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: K3TM (SybronEndo,Glendora, CA, USA), Mtwo (VDW GmbH, Mu¨nchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile R (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper R (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper R, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper R produced significantly more screw-in effects than any other instruments in the study (p <0.001). K3TM produced significantly more screw-in effects than Mtwo, and ProFile (p < 0.001). There was no significant difference among Mtwo, NRT, and ProFile R (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference. [J Kor Acad Cons Dent 35(4):267-272, 2010]
참고문헌 (20)
- Schilder H, "Cleaning and shaping the root canal", Dent Clin Nor Am, 18, pp.269~296 (1974)
- Walia H, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
- Glosson CR, "A comparison of root canal preparations using nickel-titanium hand, nickel-titanium engine-driven, and K-flex endodontic instruments", J Endod, 21, pp.146~151 (1995)
- Huh YJ, "Change in root canal configuration using different file types and techniques", J Kor Acad Conserv Dent, 22, pp.291~304 (1997)
- 박완기, "다양한 엔진 구동형 파일의 근관 성형 능력 비교", 대한치과보존학회지, 29(1), pp.44~50 (2004), 대한치과보존학회
- Yun HH,Kim SK, "A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 95, pp.228~233 (2003)
- Short JA, "A comparison of canal centering ability of four instrumentation technique", J Endod, 23, pp.503~507 (1997)
- Swartz DB, "Griffin Jr JA. Twenty years of endodontic success and failure", J Endod, 9(5), pp.198~202 (1983)
- Sj¨ogren U, "Factors affecting the long-term result of endodontic treatment", J Endod, 16(10), pp.498~504 (1990)
- Smith CS, "Factors influencing the success of conventional root canal therapy-a fiveyear retrospective study", Int Endod J, 26, pp.321~333 (1993)
- Malueg LA, "Examination of external apical root resorption with scanning electron microscopy", Oral Surg Oral. Med Oral Pathol, 82, pp.89~93 (1996)
- Gutierrez JH, "Human teeth with periapical pathosis after overinstrumentation and overfilling of the root canals: a scanning electron microscopic study", Int Endod J, 32, pp.40~48 (1999)
- Tronstad L, "pH changes in dental tissue after root canal filling with calcium hydroxide", J Endod, 7(1), pp.17~21 (1981)
- Nehammer CF, "Treatment of the emergency patient", Br Dent J, 158, pp.245~248 (1985)
- Seltzer S, "Biologic aspects of endodontics. Part III. Periapical tissue reaction to root canal instrumentation", Oral Surg Oral Med Oral Pathol, 26(4), pp.534~546 (1968)
- Peter M, "A dozen way to prevent nickel-titanium rotary instrument fracture", J Am Dent Assoc, 138, pp.196~201 (2007)
- Li UM, "Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic test", J Endod, 28(6), pp.448~451 (2002)
- Gulabivala K, "The influence of interfacial forces and duration of filing on root canal shaping", Endod Dent Traumatol, 16, pp.166~174 (2000)
- 오승희, "학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교", 대한치과보존학회지, 31(6), pp.477~484 (2006), 대한치과보존학회
- Diemer F, "Effect of pitch length on the behavior of rotary triple helix root canal instruments", J Endod, 30(10), pp.716~718 (2004)