본문 바로가기
KERD
논문KCI 등재

Influence of root canal curvature on the screw-in effect of nickel-titanium rotary files in simulated resin root canal

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: Nickel-titanium (Ni-Ti) rotary instruments have some unexpected disadvantages including the tendency to screw-in to the canal. The purpose of this study was to evaluate the influence of root canal curvatures on the screw-in effect of Ni-Ti rotary files. Materials and Methods: A total of 80 simulated root canals in clear resin blocks were used in the study. Canals with curvature of 0, 10, 20 and 30 degrees were instrumented with ProTaper instruments SX, S1,S2 and a ProFile of #25/0.06 to 1.0-2.0 mm beyond the initial point of root curvature. The screw-in force was measured with a specially designed device while canal was instrumented with a ProFile of #30/0.06 at a constant speed of 300 rpm. The data were subjected to one-way ANOVA and Scheffe multiple range test for post-hoc test. Results: Larger degree of canal curvature generated significantly lesser screw-in forces in all groups (p <0.001). Conclusions: More attention needs to be paid when using rotary instruments in canals with less curvature than canals with more curvatures to prevent or reduce any accidental overinstrumentation. [J Kor Acad Cons Dent 2010;35(5):374-379.]

Abstract

Objectives: Nickel-titanium (Ni-Ti) rotary instruments have some unexpected disadvantages including the tendency to screw-in to the canal. The purpose of this study was to evaluate the influence of root canal curvatures on the screw-in effect of Ni-Ti rotary files. Materials and Methods: A total of 80 simulated root canals in clear resin blocks were used in the study. Canals with curvature of 0, 10, 20 and 30 degrees were instrumented with ProTaper instruments SX, S1,S2 and a ProFile of #25/0.06 to 1.0-2.0 mm beyond the initial point of root curvature. The screw-in force was measured with a specially designed device while canal was instrumented with a ProFile of #30/0.06 at a constant speed of 300 rpm. The data were subjected to one-way ANOVA and Scheffe multiple range test for post-hoc test. Results: Larger degree of canal curvature generated significantly lesser screw-in forces in all groups (p <0.001). Conclusions: More attention needs to be paid when using rotary instruments in canals with less curvature than canals with more curvatures to prevent or reduce any accidental overinstrumentation. [J Kor Acad Cons Dent 2010;35(5):374-379.]

참고문헌 (35)

  1. Pettiette MT, "Evaluation of success rate of endodontic treatment performed by students with stainless-steel K-files and Nickel- Titanium hand files", J Endod, 27, pp.124~127 (2001)
  2. Al-Omari MA, "Comparison of six files to prepare simulated root canals. Part 2", Int Endod J, 25, pp.67~81 (1992)
  3. Nagy CD, "The effect of root canal morphology on canal shape following instrumentation using different techniques", Int Endod J, 30, pp.133~140 (1997)
  4. Peters OA, "ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy", Int Endod J, 36, pp.93~99 (2003)
  5. Esposito PT, "A comparison of canal preparation with nickel-titanium and stainless steel instruments", J Endod, 21, pp.173~176 (1995)
  6. Glosson CR, "A comparison of root canal preparations using nickel-titanium hand, nickel-titanium engine-driven, and K-flex endodontic instruments", J Endod, 21, pp.146~151 (1995)
  7. Short JA, "A comparison of canal centering ability of four instrumentation techniques", J Endod, 23, pp.503~507 (1997)
  8. Huh YJ, "Change in root canal configuration using different file types and techniques", J Kor Acad Cons Dent, 22, pp.291~304 (1997)
  9. Sj¨ogren U, "Factors Affecting the Long-term Result of Endodontic Treatment", J Endod, 16, pp.498~504 (1990)
  10. 박완기, "다양한 엔진 구동형 파일의 근관 성형 능력 비교", 대한치과보존학회지, 29(1), pp.44~50 (2004), 대한치과보존학회
  11. Walia H, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
  12. Yun HH, "A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 95, pp.228~233 (2003)
  13. 하정홍, "COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL", 대한치과보존학회지, 35(4), pp.267~272 (2010), 대한치과보존학회
  14. 오승희, "학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교", 대한치과보존학회지, 31(6), pp.477~484 (2006), 대한치과보존학회
  15. Gutierrez JH, "Human teeth with periapical pathosis after overinstrumentation and overfilling of the root canals: a scanning electron microscopic study", Int Endod J, 32, pp.40~48 (1999)
  16. Leslie Ann Malueg, "Examination of external apical root resorption with scanning electron microscopy", Oral Surg Oral. Med Oral Pathol, 82, pp.89~93 (1996)
  17. Seltzer S, "Biologic aspects of endodontics. Part III. Periapical tissue reaction to root canal instrumentation", Oral Surg Oral Med Oral Pathol, 26, pp.534~546 (1968)
  18. Shimon F, "Evaluation of success and failure after endodontic therapy using a glass ionomer cement sealer", J Endod, 21, pp.384~390 (1995)
  19. Smith CS, "Factors influencing the success of conventional root canal therapy-a fiveyear retrospective study", Int Endod J, 26, pp.321~333 (1993)
  20. Diemer F, "Effect of Pitch Length on the Behavior of Rotary Triple Helix Root Canal Instruments", J Endod, 30, pp.716~718 (2004)
  21. Schra ¨der C, "Analysis of torque and force with differently tapered rotary endodontic instruments in vitro", J Endod, 31, pp.120~123 (2005)
  22. Sung HJ, "Influence of taper on the screw-in effect of nickel-titanium rotary files", 석사, pp.2006
  23. Schilder H, "Cleaning and shaping the root canal", Dent Clin Nor Am, 18, pp.269~296 (1974)
  24. Weine FS, "The effect of preparation procedures on original canal shape and on apical foramen shape", J Endod, 1, pp.255~262 (1975)
  25. Sabal CL, "Instrumentation of curved canals using a modofied tipped instrument: a comparison study", J Endod, 14, pp.59~64 (1988)
  26. Schneider SW, "A comparison of canal preparations in straight and curved root canals", Oral Surg Oral Med Oral Pathol, 32, pp.271~275 (1971)
  27. Leeb J, "Canal orifice enlargement as related to biomechanical preparation", J Endod, 9, pp.463~470 (1983)
  28. Contreras MAL, "Comparison of the first file that fits at the apex, before and after early flaring", J Endod, 27, pp.113~116 (2001)
  29. Tan BT, "The effect of instrument type and preflaring on apical file size determination", Int Endod J, 35, pp.752~758 (2002)
  30. Thompson SA, "Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals, part 1", Int Endod J, 33, pp.248~254 (2000)
  31. Johnson BW, "ndodontics: what, when, and why. In: Contemporary endodontics Dentsply Asia", pp.1~6 (2002)
  32. Hal¨ kel Y, "Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instrument", J Endod, 25, pp.434~440 (1999)
  33. Roane JB, "The “balanced force”concept for instrumentation of curved canals", J Endod, 11, pp.203~211 (1985)
  34. Kyomen SM, "Critical analysis of the balanced force technique in endodontics", J Endod, 20, pp.332~337 (1994)
  35. Wildey WL, "Another look at root canal instrumentation", Oral Surg Oral Med Oral Pathol, 74, pp.499~507 (1992)

관련 논문AI추천

이 간행물의 다른 논문 (10건)