Background: Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. Methods: The effective dose (ED) was measured with a digital dosimeter on the radiographers’ left chest and the side of the table. We observed the location of the radiographers in each procedure related to the mobile support structure of the fluoroscope (Groups A, M and P). Data about age, height, weight, sex, exposure time, radiation absorbed dose (RAD), and the ED at the radiographer’s chest and the side of the table was collected. Results: There were 51 cases for Group A, 116 cases for Group M and 144 cases for Group P. No significant differences were noted in the demographic data such as age, height, weight, and male to female ratio, and exposure time, RAD and ED at the side of the table. Group P had the lowest ED (0.5 ± 0.8 μSv) of all the groups (Group A, 1.6 ± 2.3 μSv; Group M, 1.3 ± 1.9 μSv; P < 0.001). The ED ratio (ED on the radiographer’s chest/ED at the side of the table) of Group A was the highest, and the ED radio of Group P was the lowest of all the groups (Group A, 12.2 ± 21.5%; Group M, 5.7 ± 6.5%; Group P, 2.5 ± 6.7%; P < 0.001). Conclusions: Radiographers can easily reduce their radiation exposure by changing their position. Two steps behind the mobile support structure can effectively decrease the exposure of radiographers by about 80%.

Abstract

Background: Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. Methods: The effective dose (ED) was measured with a digital dosimeter on the radiographers’ left chest and the side of the table. We observed the location of the radiographers in each procedure related to the mobile support structure of the fluoroscope (Groups A, M and P). Data about age, height, weight, sex, exposure time, radiation absorbed dose (RAD), and the ED at the radiographer’s chest and the side of the table was collected. Results: There were 51 cases for Group A, 116 cases for Group M and 144 cases for Group P. No significant differences were noted in the demographic data such as age, height, weight, and male to female ratio, and exposure time, RAD and ED at the side of the table. Group P had the lowest ED (0.5 ± 0.8 μSv) of all the groups (Group A, 1.6 ± 2.3 μSv; Group M, 1.3 ± 1.9 μSv; P < 0.001). The ED ratio (ED on the radiographer’s chest/ED at the side of the table) of Group A was the highest, and the ED radio of Group P was the lowest of all the groups (Group A, 12.2 ± 21.5%; Group M, 5.7 ± 6.5%; Group P, 2.5 ± 6.7%; P < 0.001). Conclusions: Radiographers can easily reduce their radiation exposure by changing their position. Two steps behind the mobile support structure can effectively decrease the exposure of radiographers by about 80%.

참고문헌 (20)

  1. 백승우, "A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block", The Korean Journal of Pain, 26(2), pp.148~153 (2013), 대한통증학회
  2. 류재성, "The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room", The Korean Journal of Pain, 26(2), pp.142~147 (2013), 대한통증학회
  3. Fish DE, "The risk of radiation exposure to the eyes of the interventional pain physician", Radiol Res Pract, 2011, pp.609537~ (2011)
  4. Botwin KP, "Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections", Pain Physician, 4, pp.343~348 (2001)
  5. Manchikanti L, "Radiation exposure to the physician in interventional pain management", Pain Physician, 5, pp.385~393 (2002)
  6. 정철희, "Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures", The Korean Journal of Pain, 26(1), pp.51~56 (2013), 대한통증학회
  7. Jae Hun Cho, "A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes", The Korean Journal of Pain, 24(4), pp.199~204 (2011), 대한통증학회
  8. Occupational dose limits, In Limitation of exposure to ionizing radiation, "National Council on Radiation Protection and Measurements", National Council on Radiation Protection and Measurements, 33~35, pp.NCRP Report No. 116 (1993)
  9. Pyong Eun Park, "Radiation Safety and Education in the Applicants of the Final Test for the Expert of Pain Medicine", The Korean Journal of Pain, 25(1), pp.16~21 (2012), 대한통증학회
  10. Fink GE, "Radiation safety in fluoroscopy for neuraxial injections", AANA J, 77, pp.265~269 (2009)
  11. Little MP, "Do non-targeted effects increase or decrease low dose risk in relation to the linear-non-threshold (LNT)model?", Mutat Res, 687, pp.17~27 (2010)
  12. Shah DJ, "Radiation-induced cancer:a modern view", Br J Radiol, 85, pp.e1166~e1173 (2012)
  13. Hendee WR, "Radiation risks of medical imaging : separating fact from fantasy", Radiology, 264, pp.312~321 (2012)
  14. Crawley MT, "Radiation dose and diagnosticity of barium enema examinations by radiographers and radiologists : a comparative study", Br J Radiol, 71, pp.399~405 (1998)
  15. Tilson ER, "Educational and experiential effects on radiographers'radiation safety behavior", Radiol Technol, 53, pp.321~325 (1982)
  16. Johnston J, "Technologists'radiation exposure perceptions and practices", Radiol Technol, 82, pp.311~320 (2011)
  17. Vano E, "Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology", Radiat Prot Dosimetry, 118, pp.325~330 (2006)
  18. Mohamed Amin Ghobadifar, "Effect of Collimation on Radiation Exposure and Image Quality", The Korean Journal of Pain, 26(3), pp.307~308 (2013), 대한통증학회
  19. Miller DL, "Occupational radiation protection in interventional radiology:a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology", Cardiovasc Intervent Radiol, 33, pp.230~239 (2010)
  20. Schueler BA, "Operator shielding : how and why", Tech Vasc Interv Radiol, 13, pp.167~171 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (13건)