A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes

2

조회

0

다운로드

10

인용

0

참고문헌

키워드

초록

Background:Although many clinicians know about the reducing effects of the pulsed and low-dose modes for fluoroscopic radiation when performing interventional procedures, few studies have quantified the reduction of radiation-absorbed doses (RADs). The aim of this study is to compare how much the RADs from a fluoroscopy are reduced according to the C-arm fluoroscopic modes used. Methods:We measured the RADs in the C-arm fluoroscopic modes including ‘conventional mode’, ‘pulsed mode’, ‘low-dose mode’, and ‘pulsed + low-dose mode’. Clinical imaging conditions were simulated using a lead apron instead of a patient. According to each mode, one experimenter radiographed the lead apron, which was on the table, consecutively 5 times on the AP views. We regarded this as one set and a total of 10 sets were done according to each mode. Cumulative exposure time, RADs, peak X-ray energy, and current, which were viewed on the monitor, were recorded. Results:Pulsed, low-dose, and pulsed + low-dose modes showed significantly decreased RADs by 32%, 57%, and 83% compared to the conventional mode. The mean cumulative exposure time was significantly lower in the pulsed and pulsed + low-dose modes than in the conventional mode. All modes had pretty much the same peak X-ray energy. The mean current was significantly lower in the low-dose and pulsed + low-dose modes than in the conventional mode. Conclusions:The use of the pulsed and low-dose modes together significantly reduced the RADs compared to the conventional mode. Therefore, the proper use of the fluoroscopy and its C-arm modes will reduce the radiation exposure of patients and clinicians. (Korean J Pain 2011; 24: 199-204)

Abstract

Background:Although many clinicians know about the reducing effects of the pulsed and low-dose modes for fluoroscopic radiation when performing interventional procedures, few studies have quantified the reduction of radiation-absorbed doses (RADs). The aim of this study is to compare how much the RADs from a fluoroscopy are reduced according to the C-arm fluoroscopic modes used. Methods:We measured the RADs in the C-arm fluoroscopic modes including ‘conventional mode’, ‘pulsed mode’, ‘low-dose mode’, and ‘pulsed + low-dose mode’. Clinical imaging conditions were simulated using a lead apron instead of a patient. According to each mode, one experimenter radiographed the lead apron, which was on the table, consecutively 5 times on the AP views. We regarded this as one set and a total of 10 sets were done according to each mode. Cumulative exposure time, RADs, peak X-ray energy, and current, which were viewed on the monitor, were recorded. Results:Pulsed, low-dose, and pulsed + low-dose modes showed significantly decreased RADs by 32%, 57%, and 83% compared to the conventional mode. The mean cumulative exposure time was significantly lower in the pulsed and pulsed + low-dose modes than in the conventional mode. All modes had pretty much the same peak X-ray energy. The mean current was significantly lower in the low-dose and pulsed + low-dose modes than in the conventional mode. Conclusions:The use of the pulsed and low-dose modes together significantly reduced the RADs compared to the conventional mode. Therefore, the proper use of the fluoroscopy and its C-arm modes will reduce the radiation exposure of patients and clinicians. (Korean J Pain 2011; 24: 199-204)

참고문헌 (14)

  1. Raj PP, "Interventional pain management: Image-guided procedures", pp.11~ (2008), Saunders Elsevier
  2. Tae Wan Kim, "Radiation Exposure to Physicians During Interventional Pain Procedures", The Korean Journal of Pain, 23(1), pp.24~27 (2010), 대한통증학회
  3. Goodman BS, "Reduction in average fluoroscopic exposure times for interventional spinal procedures through the use of pulsed and low-dose image settings", Am J Phys Med Rehabil (2011)
  4. Cousins C, "Medical interventional procedures- reducing the radiation risks", Clin Radiol, 59, pp.468~473 (2004)
  5. Mroz TE, "Radiation exposure to the surgeon and the patient during kyphoplasty", J Spinal Disord Tech, 21, pp.96~100 (2008)
  6. Miller DL, "Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology", Cardiovasc Intervent Radiol, 33, pp.230~239 (2010)
  7. Brown PH, "Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging", Pediatr Radiol, 30, pp.229~235 (2000)
  8. Cohen MD, "Can we use pulsed fluoroscopy to decrease the radiation dose during video fluoroscopic feeding studies in children", Clin Radiol, 64, pp.70~73 (2009)
  9. Cohen MD, "Optimizing the use of pulsed fluoroscopy to reduce radiation exposure to children", J Am Coll Radiol, 5, pp.205~209 (2008)
  10. Rathmell JP, "Atlas of image-guided intervention in regional anesthesia and pain medicine", pp.9~15 (2006), Lippincott Williams & Wilkins
  11. Uppot RN, "Effect of obesity on image quality: fifteen-year longitudinal study for evaluation of dictated radiology reports", Radiology, 240, pp.435~439 (2006)
  12. Wagner LK, "Management of patient skin dose in fluoroscopically guided interventional procedures", J Vasc Interv Radiol, 11, pp.25~33 (2000)
  13. Aufrichtig R, "Perceptual comparison of pulsed and continuous fluoroscopy", Med Phys, 21, pp.245~256 (1994)
  14. Brown PH, "A multihospital survey of radiation exposure and image quality in pediatric fluoroscopy", Pediatr Radiol, 30, pp.236~242 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (10건)