Radiation safety for pain physicians: principles and recommendations
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician’s but also the patient’s radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician’s and patient’s radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.
Abstract
C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician’s but also the patient’s radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician’s and patient’s radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.
참고문헌 (58)
- Tapio S, "Ionizing radiation-induced circulatory and metabolic diseases", Environ Int, 146, pp.106235~ (2021)
- Paulo G, "Radiation dose of patients in fluoroscopically guided interventions : an update", Cardiovasc Intervent Radiol, 44, pp.842~848 (2021)
- Vera GV, "Assessment of genome damage in occupational exposure to ionising radiation and ultrasound", Mutat Res, 395, pp.101~105 (1997)
- Maffei F, "Spectrum of chromosomal aberrations in peripheral lymphocytes of hospital workers occupationally exposed to low doses of ionizing radiation", Mutat Res, 547, pp.91~99 (2004)
- Milacic S, "Risk of occupational radiation-induced cataract in medical workers", Med Lav, 100, pp.178~186 (2009)
- Mastrangelo G, "Increased cancer risk among surgeons in an orthopaedic hospital", Occup Med (Lond), 55, pp.498~500 (2005)
- Roguin A, "Brain and neck tumors among physicians performing interventional procedures", Am J Cardiol, 111, pp.1368~1372 (2013)
- Chartier H, "Occupational low-dose irradiation and cancer risk among medical radiation workers", Occup Med(Lond), 70, pp.476~484 (2020)
- Schueler BA, "Operator shielding : how and why", Tech Vasc Interv Radiol, 13, pp.167~171 (2010)
- Dagal A, "Radiation safety for anesthesiologists", Curr Opin Anaesthesiol, 24, pp.445~450 (2011)
- 천보경, "Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management", The Korean Journal of Pain, 31(4), pp.244~252 (2018), 대한통증학회
- Valentin J, "Avoidance of radiation injuries from medical interventional procedures", Ann ICRP, 30, pp.7~67 (2000)
- Vano E, "Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology", Radiat Prot Dosimetry, 118, pp.325~330 (2006)
- Manchikanti L, "Radiation exposure to the physician in interventional pain management", Pain Physician, 5, pp.385~393 (2002)
- Madder RD, "Patient body mass index and physician radiation dose during coronary angiography", Circ Cardiovasc Interv, 12, pp.e006823~ (2019)
- 창용재, "The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions", The Korean Journal of Pain, 27(2), pp.162~167 (2014), 대한통증학회
- Fink GE, "Radiation safety in fluoroscopy for neuraxial injections", AANA J, 77, pp.265~269 (2009)
- Peled A, "Ionizing radiation and the risk for cataract and lens opacities", Harefuah, 157, pp.650~654 (2018)
- Albi E, "Radiation and thyroid cancer", Int J Mol Sci, 18, pp.911~ (2017)
- National Council on Radiation Protection and Measurements, "Limitation of exposure to ionizing radiation: recommendations of the National Council on Radiation Protection and Measurements", National Council on Radiation Protection and Measurements, 1~86 (1993)
- Hamada N, "Role of carcinogenesis related mechanisms in cataractogenesis and its implications for ionizing radiation cataractogenesis", Cancer Lett, 368, pp.262~274 (2015)
- Authors on behalf of ICRP, "ICRP publication 118 : ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context", Ann ICRP, 41, pp.1~322 (2012)
- Dauer LT, "Guidance on radiation dose limits for the lens of the eye: overview of the recommendations in NCRP Commentary No. 26", Int J Radiat Biol, 93, pp.1015~1023 (2017)
- 김민정, "통증 치료에서의 방사선 노출에 의한 눈의 영향과 보호", Anesthesia and Pain Medicine, 12(4), pp.297~305 (2017), 대한마취통증의학회
- Eun Joo Choi, "Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit", The Korean Journal of Pain, 33(1), pp.73~80 (2020), 대한통증학회[DOI]
- Management of exposure to ionizing radiation: radiation protection guidance for the United States, "National Council on Radiation Protection and Measurements", National Council on Radiation Protection and Measurements, ~, pp.Report No.: 180 (2018)
- Rivett C, "An assessment of the dose reduction of commercially available lead protective glasses for interventional radiology staff", Radiat Prot Dosimetry, 172, pp.443~452 (2016)
- Magee JS, "Derivation and application of dose reduction factors for protective eyewear worn in interventional radiology and cardiology", J Radiol Prot, 34, pp.811~823 (2014)
- Miller DL, "Occupational radiation protection in interventional radiology : a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology", Cardiovasc Intervent Radiol, 33, pp.230~239 (2010)
- Kuipers G, "Evaluation of the occupational doses of interventional radiologists", Cardiovasc Intervent Radiol, 31, pp.483~489 (2008)
- Wang RR, "Occupational Radiation exposure of anesthesia providers : a summary of key learning points and resident-led radiation safety projects", Semin Cardiothorac Vasc Anesth, 21, pp.165~171 (2017)
- Bryant PA, "Integration of risks from multiple hazards into a holistic ALARA", ALARP demonstration, 2018, pp.38, 81~91
- 김재헌, "Three principles for radiation safety: time, distance, and shielding", The Korean Journal of Pain, 31(3), pp.145~146 (2018), 대한통증학회
- Shuler FD, "Laser targeting with C-arm fluoroscopy : effect on image acquisition and radiation exposure", J Orthop Trauma, 27, pp.e97~e102 (2013)
- 김아나, "How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?", The Korean Journal of Pain, 27(2), pp.145~151 (2014), 대한통증학회
- 정철희, "Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures", The Korean Journal of Pain, 26(1), pp.51~56 (2013), 대한통증학회
- Livingstone RS, "A simple quality control tool for assessing integrity of lead equivalent aprons", Indian J Radiol Imaging, 28, pp.258~262 (2018)
- Fakhoury E, "Not all lightweight lead aprons and thyroid shields are alike", J Vasc Surg, 70, pp.246~250 (2019)
- Singer G, "Occupational radiation exposure to the surgeon", J Am Acad Orthop Surg, 13, pp.69~76 (2005)
- Hong SW, "Radiation exposure to the back with different types of aprons", Radiat Prot Dosimetry, 193, pp.185~189 (2021)
- Livingstone RS, "A study on the use of radiation-protective apron among interventionists in radiology", J Clin Imaging Sci, 8, pp.34~ (2018)
- Chou LB, "Prevalence of cancer in female orthopaedic surgeons in the United States", J Bone Joint Surg Am, 92, pp.240~244 (2010)
- Müller LP, "Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing", Injury, 29, pp.461~468 (1998)
- Lee SY, "Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy", Spine (Phila Pa 1976), 38, pp.2108~2112 (2013)
- Wagner LK, "Radiation-attenuating surgical gloves : effects of scatter and secondary electron production", Radiology, 200, pp.45~48 (1996)
- Cousin AJ, "The case for radioprotective eyewear", facewear. Practical implications and suggestions, 1987, pp.22, 688~692
- Kirkwood ML, "Novel modification to leaded eyewear results in significant operator eye radiation dose reduction", J Vasc Surg, 72, pp.2139~2144 (2020)
- Koukorava C, "Efficiency of radiation protection equipment in interventional radiology : a systematic Monte Carlo study of eye lens and whole body doses", J Radiol Prot, 34, pp.509~528 (2014)
- Lian Y, "Protracted lowdose radiation exposure and cataract in a cohort of Chinese industry radiographers", Occup Environ Med, 72, pp.640~647 (2015)
- Maina PM, "Investigation of radiation protection and safety measures in Rwandan public hospitals : readiness for the implementation of the new regulations", J Med Imaging Radiat Sci, 51, pp.629~638 (2020)
- 류재성, "The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room", The Korean Journal of Pain, 26(2), pp.142~147 (2013), 대한통증학회
- Christodoulou EG, "Evaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including the contribution from backscatter", Med Phys, 30, pp.1033~1038 (2003)
- Brown PH, "Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging", Pediatr Radiol, 30, pp.229~235 (2000)
- Jae Hun Cho, "A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes", The Korean Journal of Pain, 24(4), pp.199~204 (2011), 대한통증학회
- Aufrichtig R, "Perceptual comparison of pulsed and continuous fluoroscopy", Med Phys, 21, pp.245~256 (1994)
- 백승우, "A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block", The Korean Journal of Pain, 26(2), pp.148~153 (2013), 대한통증학회
- Mahesh M, "Fluoroscopy : patient radiation exposure issues", Radiographics, 21, pp.1033~1045 (2001)
- 김태희, "The radiation safety education and the pain physicians’efforts to reduce radiation exposure", The Korean Journal of Pain, 30(2), pp.104~115 (2017), 대한통증학회