초록

Purpose: To evaluate RBM surface implant which has its good character like that good initial stability, early bone formation. Material and Methods: In this study fixures have divided in 2 group: Machined(Group Ⅰ), RBM(Group Ⅱ). Total 10 fixtures were implanted on rabbit which sacrificed on week 2 and week 4 for the histological specimens. By these specimens polarized microscopic view, micro CT view, ISQ value were measured, compared and analysed by each group to figure out the evidence that clinical use of RBM implant. Result: ISQ value had no significance differences between 2 groups, However in each group 4, 8 weeks had higher ISQ value than 2 weeks. In polarized microscope, calcification level was following : Group Ⅱ, Group Ⅰ. In micro CT, formation of cancellous bone level was following : Group Ⅱ, Group Ⅰ. Conclusion: RBM implant was the most excellent on the early bone formation and good initial stability. (J Korean Acad Periodontol 2008;38:467-474)

Abstract

Purpose: To evaluate RBM surface implant which has its good character like that good initial stability, early bone formation. Material and Methods: In this study fixures have divided in 2 group: Machined(Group Ⅰ), RBM(Group Ⅱ). Total 10 fixtures were implanted on rabbit which sacrificed on week 2 and week 4 for the histological specimens. By these specimens polarized microscopic view, micro CT view, ISQ value were measured, compared and analysed by each group to figure out the evidence that clinical use of RBM implant. Result: ISQ value had no significance differences between 2 groups, However in each group 4, 8 weeks had higher ISQ value than 2 weeks. In polarized microscope, calcification level was following : Group Ⅱ, Group Ⅰ. In micro CT, formation of cancellous bone level was following : Group Ⅱ, Group Ⅰ. Conclusion: RBM implant was the most excellent on the early bone formation and good initial stability. (J Korean Acad Periodontol 2008;38:467-474)

참고문헌 (31)

  1. Bränemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Almquist and Wiksell International (1977)
  2. Levine RA, "Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Results of loading for two or more years", Int J Oral Maxillofac Implants, 14, pp.516~520 (1999)
  3. Lekholm U, "Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5year muticenter study", Int J Oral Maxillofac Implants, 9, pp.627~635 (1994)
  4. Buser D, "Long-term evaluation of non-submerged ITI implants. Part 1 : 8-year life table analysis of a prospctive multi-center study with 2359 implants", Clin Oral Implants Res, 8, pp.161~172 (1997)
  5. Tolman DE, "Tissue-integrated prothesis complications", Int J Oral Maxillofac Implants, 7, pp.477~484 (1992)
  6. Balshi TJ, "An analysis and management of fractured implants: A clinical report", Int J Oral Maxillofac Implants, 11, pp.660~666 (1996)
  7. Ragnar A, "A long-term follow up study of osseointegrated implants in the treatment of totally edentulous jaws", Int J Oral Maxillofac Implants, 14, pp.210~216 (1990)
  8. Eliades T, "Passive film growth on titanium alloys: Physico-chemical and biological consideration", Int J Oral Maxillofac Implants, 12, pp.621~627 (1997)
  9. Pan J, "Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application", Elcetrochim Acta, 41, pp.1143~1153 (1996)
  10. Wennerberg A, "Torque and histomorphometric and removal torque study of screw-shaped titanium implants and 75um sized particles of Al2O3", Journal of Biomedical Materials Research, 30, pp.251~260 (1996)
  11. Buser D, "Influence of surface characteristics on bone integration of titanium implants. A histomorpho-metric study in miniature pigs", Journal of Biomedical Materials Research, 25, pp.889~902 (1991)
  12. Grook K, "Plasma sprayed coating of hydroxyapatite", Journal of Biomedical Materials Research, 21, pp.1375~1381 (1987)
  13. Rasmussen L, "Measurements of stability changes of titanium implants with exposed threads subject to barrier membrane induced bone augmentation. An experimental study in the rabbit tibia", Clin Oral Implants Res, 8, pp.316~322 (1997)
  14. Da Cunha HA, "Oliveira RCG. A comparison between cutting torque and resonance frequency in the assessment of primary stability final torque capacity of standard and TiUnite single tooth implants under immediate loading", Int J Oral Maxillofac Implants, 19, pp.578~585 (2004)
  15. Barewal RM, "Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface", Int J Oral Maxillofac Implants, 19, pp.578~585 (2004)
  16. Branemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Scand J Plast Reconstr Surg, 111(16), pp.1~132 (1977)
  17. Sennerby L, "Resonance frequency analysis: Measuring implant stability and osseointegration", Compend Contin Educ Dent, 18, pp.493~502 (1998)
  18. Rasmusson L, "Implant stability measurements using resonance frequency analysis in the grafted maxilla: a cross-sectional pilot study", Clin Oral Dent Relat Res, 1, pp.70~74 (1999)
  19. Steigenga JT, "Misch CE, Want HL. Dental implant design and its relationship to long-term implant success", Implant Dent, 12, pp.306~317 (2003)
  20. Trico J, "Implant stability related to insertion torque force and bone density: an in vitro study", J Prosthet Dent, 74, pp.608~612 (1995)
  21. Faulkner MG, "The use and abuse of the periotest for 2-piece implant", abutment systems, 2001, pp.16, 486~494
  22. Becker W, "Implant stability measurements for implant placed at the time of extraction: a cohort, prospective clinical study", J Periodontal, 76, pp.391~397 (2005)
  23. Zix J, "Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study", Int J Oral Maxillofac Implants, 20, pp.747~752 (2005)
  24. Meredith N, "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", Clin Oral Implants Res, 7, pp.261~267 (1996)
  25. Meredith N, "A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants", Crit Rev Biomed Eng, 26, pp.275~391 (1998)
  26. Schwarz MS, "Computed tomography: PartⅠ. Preoperative assessment of the mandible for endosseous implant surgery", Int J Oral Maxillofac Implants, 2, pp.137~141 (1987)
  27. Schwarz MS, "Computed tomography: Part Ⅱ. Preoperative assessment of the mandible for endosseous implant surgery", Int J Oral Maxillofac Implants, 2, pp.137~141 (1987)
  28. Fanuscu MI, "Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible", Clin Oral Implants Res, 15, pp.213~218 (2004)
  29. Hanazawa T, "Radiologic measurements of the mandible: a comparison between CT-reformatted and conventional tomographic images", Clin Oral Implants Res, 15, pp.226~232 (2004)
  30. Homolka P, "Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study", Radiology, 224, pp.247~252 (2002)
  31. Homolka P, "Local calibrated bone mineral density in the mandible presented using a color coding scheme", Med Eng Phys, 23, pp.673~ (2001)

관련 논문AI추천

이 간행물의 다른 논문 (16건)