Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). Methods: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The P1–M1 teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. Results: No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants,but there was no significant difference between 4 and 8 weeks. Conclusions: The existence of microthreads was not a significant factor in mechanical and histological stability.

Abstract

Purpose: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). Methods: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The P1–M1 teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. Results: No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants,but there was no significant difference between 4 and 8 weeks. Conclusions: The existence of microthreads was not a significant factor in mechanical and histological stability.

참고문헌 (13)

  1. Klokkevold PR, "Osseointegration enhanced by chemical etching of the titanium surface : a torque removal study in the rabbit", Clin Oral Implants Res, 8, pp.442~447 (1997)
  2. Carlsson L, "Removal torques for polished and rough titanium implants", Int J Oral Maxillofac Implants, 3, pp.21~24 (1988)
  3. Shalabi MM, "The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model", Clin Oral Implants Res, 17, pp.172~178 (2006)
  4. Lee DW, "Effect of microthread on the maintenance of marginal bone level : a 3-year prospective study", Clin Oral Implants Res, 18, pp.465~470 (2007)
  5. Abrahamsson I, "Tissue characteristics at microthreaded implants : an experimental study in dogs", Clin Implant Dent Relat Res, 8, pp.107~113 (2006)
  6. Steigenga JT, "Dental implant design and its relationship to long-term implant success", Implant Dent, 12, pp.306~317 (2003)
  7. Hudieb MI, "Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant", J Periodontol, 82, pp.1061~1070 (2011)
  8. Rasmusson L, "Effects of implant design and surface on bone regeneration and implant stability : an experimental study in the dog mandible", Clin Implant Dent Relat Res, 3, pp.2~8 (2001)
  9. Misch CE, "Contemporary implant dentistry. 3rd ed" (2008), Mosby Elsevier
  10. Chung SH, "Effects of implant geometry and surface treatment on osseointegration after functional loading : a dog study", J Oral Rehabil, 35, pp.229~236 (2008)
  11. Ma P, "Influence of helix angle and density on primary stability of immediately loaded dental implants : three-dimensional finite element analysis", Zhonghua Kou Qiang Yi Xue Za Zhi, 42, pp.618~621 (2007)
  12. Chun HJ, "Evaluation of design parameters of osseointegrated dental implants using finite element analysis", J Oral Rehabil, 29, pp.565~574 (2002)
  13. Kong L, "Optimized thread pitch design and stress analysis of the cylinder screwed dental implant", Hua Xi Kou Qiang Yi Xue Za Zhi, 24, pp.509~512 (2006)

관련 논문AI추천

Histologic evaluation and removal torque analysis of nano - and micro - treated titanium implants in the dogs안석, 박상원, 방몽숙, 양홍서, 임현필대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제2호Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits고정우, 김성훈, 양재호, 이재봉, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제2호The effect of various thread designs on the initial stability of taper implants권호범, 김명주, 박주희, 임영준대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제1호성견에서 사다리꼴형 디지인과 미세나사선을 가진 단폭경임플란트의 골유착 평가:예비 연구윤정호, 장윤영대한치과의사협회 · 대한치과의사협회지2016 · 제54권 제7호Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias박경순, 조성암, Abdel Ghani Ibrahim Al Awamleh대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제1호Comparative study on the osseointegration of implants in dog mandibles according to the implant surface treatment김수관, 오지수, 유재식, 윤욱재, 임성철, 정경인, 정미애대한구강악안면외과학회 · 대한구강악안면외과학회지2016 · 제42권 제6호