본문 바로가기
KERD
논문KCI 등재

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

2

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of 2.42° (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

Abstract

Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of 2.42° (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

참고문헌 (40)

  1. Rangert B, "Bending overload and implant fracture: a retrospective clinical analysis", Int J Oral Maxillofac Implants, 10, pp.326~334 (1995)
  2. Hobkirk JA, "The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures", J Prosthet Dent, 80, pp.169~174 (1998)
  3. Stanford CM, "Biomechanical and functional behavior of implants", Adv Dent Res, 13, pp.88~92 (1999)
  4. Schwartz-Arad D, "Intraoral autogenous block onlay bone grafting for extensive reconstruction of atrophic maxillary alveolar ridges", J Periodontol, 76, pp.636~641 (2005)
  5. Maiorana C, "Maxillary and mandibular bone reconstruction with hip grafts and implants using Frialit-2 implants", Int J Periodontics Restorative Dent, 22, pp.221~229 (2002)
  6. Simion M, "Vertical ridge augmentation using a membrane technique associated with osseointegrated implants", Int J Periodontics Restorative Dent, 14, pp.496~511 (1994)
  7. Chiapasco M, "Quality and quantity of bone following alveolar distraction osteogenesis in the human mandible", Clin Oral Implants Res, 17, pp.394~402 (2006)
  8. Engelke WG, "Alveolar reconstruction with splitting osteotomy and microfixation of implants", Int J Oral Maxillofac Implants, 12, pp.310~318 (1997)
  9. Becker CM, "Surgical guide for dental implant placement", J Prosthet Dent, 83, pp.248~251 (2000)
  10. Almog DM, "Fabrication of imaging and surgical guides for dental implants", J Prosthet Dent, 85, pp.504~508 (2001)
  11. Garber DA, "The esthetic dental implant: letting restoration be the guide", J Am Dent Assoc, 126, pp.319~325 (1995)
  12. Pesun IJ, "Fabrication of a guide for radiographic evaluation and surgical placement of implants", J Prosthet Dent, 73, pp.548~552 (1995)
  13. Di Giacomo GA, "Clinical application of stereolithographic surgical guides for implant placement: preliminary results", J Periodontol, 76, pp.503~507 (2005)
  14. Sarment DP, "Stereolithographic surgical templates for placement of dental implants in complex cases", Int J Periodontics Restorative Dent, 23, pp.287~295 (2003)
  15. van Steenberghe D, "A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report", Int J Oral Maxillofac Implants, 17, pp.663~670 (2002)
  16. Sarment DP, "Accuracy of implant placement with a stereolithographic surgical guide", Int J Oral Maxillofac Implants, 18, pp.571~577 (2003)
  17. Van Assche N, "Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study", J Clin Periodontol, 34, pp.816~821 (2007)
  18. Fortin T, "Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques", J Oral Implantol, 26, pp.300~303 (2000)
  19. Fortin T, "Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine", Clin Oral Implants Res, 13, pp.651~656 (2002)
  20. Klein M, "Computer-guided surgery utilizing a computer-milled surgical template", Pract Proced Aesthet Dent, 13, pp.165~169 (2001)
  21. Widmann G, "Use of a surgical navigation system for CT-guided template production", Int J Oral Maxillofac Implants, 22, pp.72~78 (2007)
  22. Valente F, "Accuracy of computer-aided oral implant surgery: a clinical and radiographic study", Int J Oral Maxillofac Implants, 24, pp.234~242 (2009)
  23. Ersoy AE, "Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants", J Periodontol, 79, pp.1339~1345 (2008)
  24. D'haese J, "Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature", Clin Implant Dent Relat Res, 14, pp.321~335 (2012)
  25. Jung RE, "Computer technology applications in surgical implant dentistry: a systematic review", Int J Oral Maxillofac Implants, 24(Suppl), pp.92~109 (2009)
  26. Tahmaseb A, "Computer technology applications in surgical implant dentistry: a systematic review", Int J Oral Maxillofac Implants, 29(Suppl), pp.25~42 (2014)
  27. De Bruyn H, "Clinical outcome and bone preservation of single TiUnite™ implants installed with flapless or flap surgery", Clin Implant Dent Relat Res, 13, pp.175~183 (2011)
  28. Jensen OT, "Marginal bone stability using 3different flap approaches for alveolar split expansion for dental implants: a 1-year clinical study", J Oral Maxillofac Surg, 67, pp.1921~1930 (2009)
  29. Wood DL, "Alveolar crest reduction following full and partial thickness flaps", J Periodontol, 43, pp.141~144 (1972)
  30. Rousseau P, "Flapless and traditional dental implant surgery: an open, retrospective comparative study", J Oral Maxillofac Surg, 68, pp.2299~2306 (2010)
  31. Brodala N, "Flapless surgery and its effect on dental implant outcomes", Int J Oral Maxillofac Implants, 24(Suppl), pp.118~125 (2009)
  32. Sclar AG, "Guidelines for flapless surgery", J Oral Maxillofac Surg, 65(7 Suppl 1), pp.20~32 (2007)
  33. Pettersson A, "Accuracy of CAD", CAM-guided surgical template implant surgery on human cadavers: Part I, 2010, pp.103, 334~342
  34. Widmann G, "Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and image-guided surgical templates:accuracy in human cadavers", Clin Oral Implants Res, 21, pp.835~841 (2010)
  35. Schneider D, "A systematic review on the accuracy and the clinical outcome of computerguided template-based implant dentistry", Clin Oral Implants Res, 20(Suppl 4), pp.73~86 (2009)
  36. Van Assche N, "Accuracy assessment of computer-assisted flapless implant placement in partial edentulism", J Clin Periodontol, 37, pp.398~403 (2010)
  37. Ozan O, "Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement", J Oral Maxillofac Surg, 67, pp.394~401 (2009)
  38. Widmann G, "Accuracy in computer-aided implant surgery:a review", Int J Oral Maxillofac Implants, 21, pp.305~313 (2006)
  39. Cassetta M, "Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgiguide", Int J Oral Maxillofac Surg, 40, pp.1377~1387 (2011)
  40. D'haese J, "A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae", Clin Implant Dent Relat Res, 14, pp.293~303 (2012)

관련 논문AI추천

An assessment of template-guided implant surgery in terms of accuracy and related factors김명주, 김명진, 김성민, 박지만, 이재호, 이종호대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제4호Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study안서영, 이규복, 이두형, 전경배, 홍민호대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제3호Influence of template design on the accuracy of static computer-assisted implant surgery배아란, 홍성진, Hyeonseong Son, Jinmook Chung, Junghyun Park대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제1호The accuracy of a 3D printing surgical guide determined by CBCT and model analysis마보영, 박태석, 윤귀덕, 전인곤대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제4호Clinical Precautions for Implant Placement using Computer-guided Implant Surgical Guide: A Systematic Review배재휘, 이수영대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2021 · 제25권 제4호Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro studyBayad Jaza Mahmood, Dler Raouf Hama대한치주과학회 · Journal of Periodontal & Implant Science2023 · 제53권 제5호

이 간행물의 다른 논문 (7건)