Purpose. This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs. Materials and methods. Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1-4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5-6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models. Results. While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation. Conclusion. Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.

Abstract

Purpose. This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs. Materials and methods. Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1-4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5-6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models. Results. While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation. Conclusion. Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.

관련 논문AI추천

An assessment of template-guided implant surgery in terms of accuracy and related factors김명주, 김명진, 김성민, 박지만, 이재호, 이종호대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제4호Accuracy of computer-aided template-guided oral implant placement: a prospective clinical studyCarlo Maiorana, Mario Beretta, Pier Paolo Poli대한치주과학회 · Journal of Periodontal & Implant Science2014 · 제44권 제4호Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study안서영, 이규복, 이두형, 전경배, 홍민호대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제3호Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro studyBayad Jaza Mahmood, Dler Raouf Hama대한치주과학회 · Journal of Periodontal & Implant Science2023 · 제53권 제5호Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study송영우, 유승하, 정의원대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제1호Clinical Precautions for Implant Placement using Computer-guided Implant Surgical Guide: A Systematic Review배재휘, 이수영대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2021 · 제25권 제4호

이 간행물의 다른 논문 (4건)