본문 바로가기
KERD
논문KCI 등재

Clinical Precautions for Implant Placement using Computer-guided Implant Surgical Guide: A Systematic Review

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: The purpose of this study was to review the literature related to implant deviations that may occur when using a computer-guided implant surgical guide and to consider clinical precautions to reduce these deviations when placing implants using a computer-guided implant surgical guide. Materials and Methods: Articles published between 2010 and 2020 were searched in PubMed according to custom criteria. The selected articles were classified according to the cause of the deviation, and the degree of the deviation was analyzed. Results: Twelve articles were included based on the selection criteria. During implant surgery using a computer-guided implant surgical guide, various implant deviations were observed depending on the implant location, sleeve, drill, implant system, residual teeth, and 3D printer type. Conclusion: Deviations in implant placement can occur even when computer-guided implant surgical guide are used. It is necessary to recognize the possibility of implant deviations occurring according to various clinical situations and attempt to reduce these deviations.

Abstract

Purpose: The purpose of this study was to review the literature related to implant deviations that may occur when using a computer-guided implant surgical guide and to consider clinical precautions to reduce these deviations when placing implants using a computer-guided implant surgical guide. Materials and Methods: Articles published between 2010 and 2020 were searched in PubMed according to custom criteria. The selected articles were classified according to the cause of the deviation, and the degree of the deviation was analyzed. Results: Twelve articles were included based on the selection criteria. During implant surgery using a computer-guided implant surgical guide, various implant deviations were observed depending on the implant location, sleeve, drill, implant system, residual teeth, and 3D printer type. Conclusion: Deviations in implant placement can occur even when computer-guided implant surgical guide are used. It is necessary to recognize the possibility of implant deviations occurring according to various clinical situations and attempt to reduce these deviations.

참고문헌 (16)

  1. Verde MA, "A dual-purpose stent for the implant-supported prosthesis", J Prosthet Dent, 69, pp.276~280 (1993)
  2. Sommacal B, "Evaluation of two 3D printers for guided implant surgery", Int J Oral Maxillofac Implants, 33, pp.743~746 (2018)
  3. Laverty DP, "Flapless dental implant surgery and use of cone beam computer tomography guided surgery", Br Dent J, 224, pp.601~611 (2018)
  4. Eftekhar AR, "Accuracy of static digital surgical guides for dental implants based on the guide system : a systematic review", J Stomatol Oral Maxillofac Surg, 122, pp.600~607 (2020)
  5. Mario Beretta, "Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study", Journal of Periodontal & Implant Science, 44(4), pp.184~193 (2014), 대한치주과학회
  6. Tatakis DN, "Guided implant surgery risks and their prevention", Periodontol 2000, 81, pp.194~208 (2019)
  7. Al YF, "Is digital guided implant surgery accurate and reliable?", Dent Clin North Am, 63, pp.381~397 (2019)
  8. Apostolakis D, "CAD", CAM implant surgical guides: maximum errors in implant positioning attributable to the properties of the metal sleeve, Int J Implant Dent, pp.2018, 4[DOI]
  9. Van AN, "Accuracy of computeraided implant placement", Clin Oral Implants Res, 23, pp.112~123 (2012)
  10. Lin CC, "Stereolithographic surgical guide with a combination of tooth and bone support : accuracy of guided implant surgery in distal extension situation", J Clin Med, 9, pp.709~ (2020)
  11. Toyoshima T, "Accuracy of implant surgery with surgical guide by inexperienced clinicians : an in vitro study", Clin Exp Dent Res, 1, pp.10~17 (2015)
  12. Koop R, "Tolerance within the sleeve inserts of different surgical guides for guided implant surgery", Clin Oral Implants Res, 24, pp.630~634 (2013)
  13. Schneider D, "In-vitro evaluation of the tolerance of surgical instruments in templates for computer-assisted guided implantology produced by 3-D printing", Clin Oral Implants Res, 26, pp.320~325 (2015)
  14. Yeung M, "Accuracy and precision of 3D-printed implant surgical guides with different implant systems : an in vitro study", J Prosthet Dent, 123, pp.821~828 (2020)
  15. El Kholy K, "Influence of surgical guide support and implant site location on accuracy of static computer-assisted implant surgery", Clin Oral Implants Res, 30, pp.1067~1075 (2019)
  16. Oh KC, "Assessment of metal sleeve-free 3D-printed implant surgical guides", Dent Mater, 35, pp.468~476 (2019)

관련 논문AI추천

이 간행물의 다른 논문 (5건)