초록

Objectives: No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods: A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results: In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions: In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

Abstract

Objectives: No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods: A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results: In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions: In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

참고문헌 (21)

  1. Grande NM, "Current assessment of reciprocation in endodontic preparation : a comprehensive review-part I : historic perspectives and current applications", J Endod, 41, pp.1778~1783 (2015)
  2. Shen Y, "Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments", J Endod, 39, pp.163~172 (2013)
  3. Plotino G, "Current assessment of reciprocation in endodontic preparation : a comprehensive review--part II : properties and effectiveness", J Endod, 41, pp.1939~1950 (2015)
  4. Topçuoğlu HS, "Cyclic fatigue resistance of Reciproc Blue and Reciproc files in an S-shaped canal", J Endod, 43, pp.1679~1682 (2017)
  5. Özyürek T, "Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne Gold nickel-titanium instruments", J Endod, 42, pp.1536~1539 (2016)
  6. Uygun AD, "Variations in cyclic fatigue resistance among ProTaper Gold, ProTaper Next and ProTaper Universal instruments at different levels", Int Endod J, 49, pp.494~499 (2016)
  7. Emmanuel Joao Nogueira Leal Silva, "Comparison of canal transportation in simulated curved canals prepared with ProTaper Universal and ProTaper Gold systems", Restorative Dentistry and Endodontics, 41(1), pp.1~5 (2016), 대한치과보존학회
  8. Vadhana S, "Cyclic fatigue resistance of RaCe and Mtwo rotary files in continuous rotation and reciprocating motion", J Endod, 40, pp.995~999 (2014)
  9. Ahn SY, "Kinematic effects of nickel-titanium instruments with reciprocating or continuous rotation motion : a systematic review of in vitro studies", J Endod, 42, pp.1009~1017 (2016)
  10. 전영주, "Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation", 대한치과의사협회지, 52(12), pp.734~743 (2014), 대한치과의사협회[DOI]
  11. Choi DM, "Vibrations generated by several nickel-titanium endodontic file systems during canal shaping in an ex vivo model", J Endod, 43, pp.1197~1200 (2017)
  12. Di Nasso L, "Influences of 432 Hz music on the perception of anxiety during endodontic treatment : a randomized controlled clinical trial", J Endod, 42, pp.1338~1343 (2016)
  13. Kalpakjian S, "Manufacturing engineering and technology" (2001), Pearson Education
  14. Siddhpura M, "A review of chatter vibration research in turning", Int J Mach Tools Manuf, 61, pp.27~47 (2012)
  15. Quintana G, "Chatter in machining processes : a review", Int J Mach Tools Manuf, 51, pp.363~376 (2011)
  16. Zupanc J, "New thermomechanically treated NiTi alloys-a review", Int Endod J, 51, pp.1088~1103 (2018)
  17. Isik V, "Effect of shaft length on the torsional resistance of rotary nickel-titanium instruments", J Endod, 46, pp.295~300 (2020)
  18. Gagliardi J, "Evaluation of the shaping characteristics of ProTaper Gold, ProTaper NEXT, and ProTaper Universal in curved canals", J Endod, 41, pp.1718~1724 (2015)
  19. Nayak A, "Force and vibration generated in apical direction by three endodontic files of different kinematics during simulated canal preparation : an in vitro analytical study", Proc Inst Mech Eng H, 233, pp.839~848 (2019)
  20. Ruddle CJ, "Single-file shaping technique : achieving a gold medal result", Dent Today, 35, pp.98~103 (2016)
  21. 유연지, "왕복회전식 니켈-티타늄 파일을 이용한 근관 형성 시 발생하는 회전력 및 수직력에 대한 평가", 대한치과재료학회지, 41(1), pp.9~18 (2014), 대한치과재료학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (13건)