본문 바로가기
KERD
논문KCI 등재

두께에 따른 이중 중합형 복합레진의 중합

Polymeriztion of dual cured composites by different thickness

0

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류치의학

초록

The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 ㎜ (bulky filled), 4 ㎜ (bulky filled), 6 ㎜ (bulky and incrementally filled) and 8 ㎜ (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at 37℃ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with α= 0.05. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 ㎜ groups, the KHN of two materials were not affected by thickness. However, in 8 ㎜ group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 ㎜ thickness, there was no significant difference between bulk and incremental filling groups. In 8 ㎜ thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).

Abstract

The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 ㎜ (bulky filled), 4 ㎜ (bulky filled), 6 ㎜ (bulky and incrementally filled) and 8 ㎜ (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at 37℃ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with α= 0.05. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 ㎜ groups, the KHN of two materials were not affected by thickness. However, in 8 ㎜ group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 ㎜ thickness, there was no significant difference between bulk and incremental filling groups. In 8 ㎜ thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).

참고문헌 (15)

  1. Soh MS, "Effectiveness of composite cure associated with different curing modes of LED lights", Oper Dent, 28(4), pp.371~377 (2003)
  2. Feng L, "The effect of curing mode on polymerization contraction stress of a dual cured composite", J Biomed Mater Res Part B: Appl Biomater, 76(1), pp.196~202 (2005)
  3. Stavridakis MM, "Degree of remaining C=C bonds, polymerization shrinkage and stresses of dual-cured core build-up resin composites", Oper Dent, 30(4), pp.443~452 (2005)
  4. Aksornmuang J, "Mechanical properties and bond strength of dualcure resin composites to root canal dentin", Dent Mater, 23(2), pp.226~234 (2007)
  5. Yap AUJ, "Effectiveness of polymerization in composite restoratives claiming bulk placement: impact of cavity depth and exposure time", Oper Dent, 25(2), pp.113~120 (2000)
  6. Bala O, "Barcoll hardness of different resin-based composites cured by halogen or light emitting diode (LED)", Oper Dent, 30(1), pp.69~74 (2005)
  7. Asmussen E, "Restorative resins: hardness and strength vs quantity of remaining double bonds", Scand J Dent Res, 90(6), pp.484~489 (1982)
  8. Soh MS, "The Effectiveness of cure of LED and halogen curing lights at varing cavity depths", Oper Dent, 28(6), pp.707~715 (2003)
  9. Ferracane JL, "Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins", Dent Mater, 1(1), pp.11~14 (1985)
  10. Knobloch LA, "Hardness and degree of conversion of posterior packable composites", Oper Dent, 29(6), pp.642~649 (2004)
  11. Poskus LT, "Influence of placement techniques on vickers and knoop hardness of class Ⅱ composite resin restorations", Dent Mater, 20(8), pp.726~732 (2004)
  12. Lovell LG, "The effects of light intensity, temperature, and comonomer composition on the polymerization behavior of dimethacrylate dental resins", J Dent Res, 78(8), pp.1469~1476 (1999)
  13. Foxtom RM, "Bonding of photo and dual-cure adhesives to root canal dentin", Oper Dent, 28(5), pp.543~551 (2003)
  14. Oooka S, "Influence of polymerization mode of dual-polymerized resin direct core foundation systems on bond strengths to bovine dentin", J Prosthet Dent, 92(3), pp.239~244 (2004)
  15. Pilo R, "Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites", Dent Mater, 8(5), pp.299~304 (1992)

관련 논문AI추천

이 간행물의 다른 논문 (8건)