성견에 발치 후 즉시 임플란트 식립시 RBM 처리된 임플란트의 골융합에 관한 연구
Comparative Study Of Osseointergration On Different Immediate Implants In Extraction Sockets Of Beagle Dogs
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Recently, immediately after losing teeth, implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materials, STAGE-1®(4.1×8mm, Lifecore, USA), SS-III®(4.0×8mm, OSSTEM, Korea) and IFI®(4.0×8 mm, DIO, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed -2 ~ -5 and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among groups(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%, respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.
Abstract
Recently, immediately after losing teeth, implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materials, STAGE-1®(4.1×8mm, Lifecore, USA), SS-III®(4.0×8mm, OSSTEM, Korea) and IFI®(4.0×8 mm, DIO, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed -2 ~ -5 and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among groups(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%, respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.
참고문헌 (31)
- "Immediate implantation of pure itanium implant into an extraction socket Report of a pilot procedure", pp.277~284
- "Immediate implant placement into extraction site", pp.333~343
- "Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man", 72, pp.1560~1571 (2001)
- "Endosseous titanium implants in extraction sockets An experimental study in monkeys", pp.50~54
- "Intraosseous anchorage of dental Prosthesis", Brnemark PI
- "A histological assessment of the initial healing response adjacent to porous - surfaced titanium alloy dental implant system in dogs", pp.1064~1070
- "Biomechanical considerations in osseointegrated prostheses", pp.843~848
- "The long-term efficacy of currently used dental implants A review and proposed criteria of success", pp.11~25
- "Influence surface characreristics in bone integration titanium implants Ahistomor -phometic study in miniature pigs", pp.889~902, Steinemann S
- "Loaded hydroxyapatite coated and grit blasted titanium implants in dogs", pp.219~225
- "Biomaterials and biomechanics in dental implant design", pp.85~97
- "Metal release from titanium experimental study", pp.502~511 (1993)
- "Implant materials, designs, and surface topographies: their effect on ossointegration. A Literature Review", 15(5), pp.675~690 (2000)
- "surface analysis of machined versus sandblasted and acid-etched titanium implants", 15(6), pp.779~784 (2000)
- "Biomaterials in dentistry", pp.145~152
- "The Periotest method for determining implant success", pp.410~413
- "Damping characteristics of bone to implant interfaces. A clinical study with the Periotest device", 6, pp.31~39 (1995)
- "Direct bone anchorage of oral implants Clinical and experimental considerations of the concept of osseointegration", pp.30~41
- "Influence of surface characteristics in bone integration titanium implants A stomor-phometic study in miniature pigs J Biomed Mater 1991", pp.889~902, Steinemann S
- "Bone response to machined and resorbable blast material titanium implants: An experimental sturdy in rabbits", 28, pp.2~8 (2003)
- "Bone response to machined and resorbable blast material titanium implants: An experimental study in rabbits", 28, pp.2~8 (2002)
- "Experimental study of bone response to a new surface treatment of endosseous titanium implants", 10, pp.126~131 (2001)
- "A 1-year follow-up of implants of differing surface roughness placedin rabbit bone", 12, pp.486~494 (1997)
- "Immediate implants placed into infected sites: A histomorphometric study in dogs", 13, pp.422~427 (1998)
- "Intefration of screw implants in the rabbit A 1 year follow-up of removal torque of titanium implants", pp.69~75
- "Evaluating the clinical performance of the Osseotite implant: defining proshetic predictability", 20, pp.628~640 (1999)
- "Immediate implant surgery: ten year clinical overview", 20, pp.1185~1196 (1999)
- "Development of a new endosseous dental implant", pp.646~651
- "A small animal model for investigating endosseous dental implants Effect of graft material on healing of endosseous porous-surfaced implants in placed in a fresh extraction socket", pp.217~112
- "et al Generation of new bone around titanium implants using a membrane technique An experimantal study in rabbits", Dahlin C
- "Titanium implants with a true periodontal ligament An alternative to osseointegrated implants", pp.113~116
