본문 바로가기
KERD
논문KCI 등재

미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과

The effect of surface treatment of the cervical area of implant on bone regeneration in mini-pig

0

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류치의학

초록

The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. 􀝚3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with OsstellTM (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was 2.66 ± 0.11 mm at US II implants group and 1.80 ± 0.13 mm at US II plus implant group. The P-B distance after 4 months of healing was 2.29 ± 0.13 mm at US II implants group and 1.25 ± 0.10 mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

Abstract

The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. 􀝚3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with OsstellTM (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was 2.66 ± 0.11 mm at US II implants group and 1.80 ± 0.13 mm at US II plus implant group. The P-B distance after 4 months of healing was 2.29 ± 0.13 mm at US II implants group and 1.25 ± 0.10 mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

참고문헌 (27)

  1. Br¨anemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Scand J Plast Reconstr Surg, 16, pp.1~132 (1977)
  2. Schulte W, "The intraosseous Al2O3(Frialit􀋓) T¨ubingen implant. Developmental status after 8 years", J Quintessence Int, 15, pp.9~26 (1984)
  3. Krump JL, "The immediate implant: a treatment alternative", Int J Oral Maxillofac Implants, 6, pp.19~23 (1991)
  4. Schwartz-Arad D, "The ways and wherefores of immediate placement of implants into fresh extraction sites: a literature review", J Periodontol, 68, pp.915~923 (1997)
  5. Albrektsson T, "Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
  6. Cooper LF, "A role of surface topography in creating and maintaining bone at titanium endosseous implants", J Prosth Dent, 84, pp.522~534 (2000)
  7. Gottlander M, "Histomorphometric studies of hydroxyapatite-coated and uncoated CP titanium threaded implants in bone", Int J Oral Maxillofac Implants, 6, pp.399~404 (1991)
  8. Wennerberg A, "A 1-year follow up of implants of differing surface roughness placed in rabbit bone", Int J Oral Maxillofac Implant, 12, pp.486~494 (1997)
  9. Botticelli D, "Resolution of bone defects of varying dimension and configuration in the marginal portion of the peri-implant bone. An experimental study in the dog", J Clin Periodontol, 31, pp.309~331 (2004)
  10. Akimoto K, "Evaluation of titanium implants placed into simulated extraction sockets: a study in dogs", Int J of Oral Maxillofac Implants, 14, pp.351~360 (1999)
  11. Wennerberg A, "A histomorphometric and removal torque study of screw-shaped titanium", Clin Oral Implants Res, 6, pp.24~30 (1995)
  12. Cochran DL, "Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A Histomorphometric study in canine mandible", J Biomed Mater Res, 40, pp.1~11 (1998)
  13. Denissen HW, "Mandibular bone response to plasma-sprayed coatings of hydroxyapatite", Int J Prosthodont, 3, pp.53~58 (1990)
  14. Stentz WC, "Effects of guided bone regeneration around commercially pure titanium and hydroxyapatite-coated dental implants. II. Histologic analysis", J Periodontol, 68, pp.933~949 (1997)
  15. Davies JE, "Mechanisms of endosseous integration", Int J Prosthodont, 11, pp.391~401 (1998)
  16. Berglundh T, "The topography of the vascular systems in the periodontal and peri-implant tissues in the dog", J Clin Periodontol, 21, pp.129~193 (1994)
  17. Abrahamsson I, "Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog", Clin Oral Implants Res
  18. Marinho VC, "Sandblasted and Acidetched Dental Implants: A histologic study in Rats", Int J Oral Maxillofac Implant, 18, pp.75~81 (2003)
  19. Botticelli D, "Bone regeneration at implants with turned or rough surfaces in self-contained defects. An experimental study in the dog", J Clin Periodontol, 32, pp.448~455 (2005)
  20. Schropp L, "Bone healing and soft tissue contour changes following single-tooth extraction: a clinical and radiographic 12-month prospective study", Int J Periodontics Restorative Dent, 23, pp.313~323 (2003)
  21. Araujo MG, "Dimensional ridge alterations following tooth extraction. An experimental study in the dog", J Clin Periodontol, 32, pp.212~218 (2005)
  22. Araujo MG, "Ridge alterations following implant placement in fresh extraction sockets: an experimental study in the dog", J Clin Periodontol, 32, pp.645~652 (2005)
  23. Sennerby L, "Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature", Int J Prosthodont, 11, pp.408~420 (1998)
  24. Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
  25. Barewall RM, "Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface", Int J Oral Maxillofac implants, 18, pp.641~651 (2003)
  26. Rasmusson L, "The influence of simultaneous versus delayed placement on the stability of titanium implants in onlay bone grafts", Int J Oral Maxillofac Implants, 28, pp.224~231 (1999)
  27. Wilson T Jr, "Implants placed in immediate extraction sites: A report of histologic and histometric analysis of human biopsies", Int J Oral Maxillofac Implants, 13, pp.333~341 (1998)

관련 논문AI추천