Purpose: The objective of this study was to compare the osseointegration of SLA® to these of Joy 1 implant®. Materials and Methods: In 6 beagle dogs, 3rd and 4th mandibular premolar were extracted bilaterally. After 3 months, four transmucosal screw-shaped implants were placed in each mandibular edentulous premolar region. Control groups were SLA® and experimental groups were Joy 1 implant®. The implants were allowed to heal for 4 or 8 weeks. At the end of the experiment, the dogs were sacrificed and each of implant sites was dissected and processed for histomorphometric analysis. Results: Histomorphometric analysis showed direct osseous integration for both implants. No significant difference between both types of implants could be detected after 4 and 8 weeks healing periods in bone to implant contact (BIC) and bone ingrowth (BI). Conclusion: The results indicate that there was no difference in osseointegration between SLA® implant and Joy 1 implant® regarding BIC and BI, Joy 1 implant® showed similar histological response with SLA® implant.
Abstract
Purpose: The objective of this study was to compare the osseointegration of SLA® to these of Joy 1 implant®. Materials and Methods: In 6 beagle dogs, 3rd and 4th mandibular premolar were extracted bilaterally. After 3 months, four transmucosal screw-shaped implants were placed in each mandibular edentulous premolar region. Control groups were SLA® and experimental groups were Joy 1 implant®. The implants were allowed to heal for 4 or 8 weeks. At the end of the experiment, the dogs were sacrificed and each of implant sites was dissected and processed for histomorphometric analysis. Results: Histomorphometric analysis showed direct osseous integration for both implants. No significant difference between both types of implants could be detected after 4 and 8 weeks healing periods in bone to implant contact (BIC) and bone ingrowth (BI). Conclusion: The results indicate that there was no difference in osseointegration between SLA® implant and Joy 1 implant® regarding BIC and BI, Joy 1 implant® showed similar histological response with SLA® implant.
참고문헌 (13)
- Brånemark PI, "Intra-osseous anchorage of dental prostheses. I. Experimental studies", Scand J Plast Reconstr Surg, 3, pp.81~100 (1969)
- Brånemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Scand J Plast Reconstr Surg Suppl, 16, pp.1~132 (1977)
- Schroeder A, "Tissue reaction to an implant of a titanium hollow cylinder with a titanium surface spray layer", SSO Schweiz Monatsschr Zahnheilkd, 86, pp.713~727 (1976)
- Albrektsson T, "The long-term effcacy of currently used dental implants: a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
- Schwartz Z, , Bone regulating mechanism on implant surfaces: proceedings of the 3rd European Workshop on Periodontology-Implant Dentistry, 1, pp.41~54 (1999)
- Gottlander M, "A histomor-phometric study of unthreaded hydroxyapatite-coated and titanium-coated implants in rabbit bone", Int J Oral Maxillofac Implants, 7, pp.485~490 (1992)
- Adell R, "Lindström J", Jacobsson M : Reconstruction of severely resorbed edentulous maxillae using osseointegrated fixtures in immediate auto-genous bone gra«s. Int J Oral Maxillofac Implants 5 : 233-246 (1990)
- Johansson C, "Integration of screw implants in the rabbit: a 1-year follow-up of removal torque of titanium implants", Int J Oral Maxillofac Implants, 2, pp.69~75 (1987)
- Buser D, "Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs", J Biomed Mater Res, 25, pp.889~902 (1991)
- Cochran DL, "Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible", J Biomed Mater Res, 40, pp.1~11 (1998)
- Keller JC, "Characterizations of titanium implant surfaces. III", J Biomed Mater Res, 28, pp.939~946 (1994)
- Salvi GE, "Early loading (2 or 6 weeks) of sandblasted and acid-etched (SLA) ITI implants in the posterior mandible. A 1-year randomized controlled clinical trial", Clin Oral Implants Res, 15, pp.142~149 (2004)
- Bornstein MM, "Bone apposition around two different sandblasted and acid-etched titanium implant surfaces: a histomorphometric study in canine mandibles", Clin Oral Implants Res, 19, pp.233~241 (2008)