Accuracy of Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigant
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: To evaluate the accuracy of the Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigants, such as saline, 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine liquid, 2% chlorhexidine gel, and RC-Prep, and also to determine the electrical conductivities of these endodontic irrigants. Materials and Methods: A root perforation was simulated on twenty freshly extracted teeth by means of a small perforation made on the proximal surface of the root at 4 mm from the anatomic apex. Root ZX was used to locate root perforation and measure the electronic working lengths. The results obtained were compared with the actual working length (AWL) and the actual location of perforations (AP), allowing tolerances of 0.5 or 1.0 mm. Measurements within these limits were considered as acceptable. Chi-square test or the Fisher’s exact test was used to evaluate significance. Electrical conductivities of each irrigant were also measured with an electrical conductivity tester. Results: The accuracies of the Root ZX in perforated teeth were significantly different between liquid types (saline, NaOCl) and gel types (chlorhexidine gel, RC-Prep). The accuracies of electronic working lengths in perforated teeth were higher in gel types than in liquid types. The accuracy in locating root perforation was higher in liquid types than gel types. 5.25% NaOCl had the highest electrical conductivity, whereas 2% chlorhexidine gel and RC-Prep gel had the lowest electrical conductivities among the five irrigants. Conclusions: Different canal irrigants with different electrical conductivities may affect the accuracy of the Root ZX in perforated teeth.
Abstract
Objectives: To evaluate the accuracy of the Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigants, such as saline, 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine liquid, 2% chlorhexidine gel, and RC-Prep, and also to determine the electrical conductivities of these endodontic irrigants. Materials and Methods: A root perforation was simulated on twenty freshly extracted teeth by means of a small perforation made on the proximal surface of the root at 4 mm from the anatomic apex. Root ZX was used to locate root perforation and measure the electronic working lengths. The results obtained were compared with the actual working length (AWL) and the actual location of perforations (AP), allowing tolerances of 0.5 or 1.0 mm. Measurements within these limits were considered as acceptable. Chi-square test or the Fisher’s exact test was used to evaluate significance. Electrical conductivities of each irrigant were also measured with an electrical conductivity tester. Results: The accuracies of the Root ZX in perforated teeth were significantly different between liquid types (saline, NaOCl) and gel types (chlorhexidine gel, RC-Prep). The accuracies of electronic working lengths in perforated teeth were higher in gel types than in liquid types. The accuracy in locating root perforation was higher in liquid types than gel types. 5.25% NaOCl had the highest electrical conductivity, whereas 2% chlorhexidine gel and RC-Prep gel had the lowest electrical conductivities among the five irrigants. Conclusions: Different canal irrigants with different electrical conductivities may affect the accuracy of the Root ZX in perforated teeth.
참고문헌 (28)
- Cohen S, "Pathways of the pulp9th ed", pp.996~ (2006), Mosby Elsevier Co
- Alhadainy HA, "Root perforations,In A review of literature", Oral Surg Oral Med Oral Pathol, 78, pp.368~374 (1994)
- Sunada I, "New method for measuring the length of the root canal", J Dent Res, 41, pp.375~387 (1962)
- Trope M, "Accuracy of an electronic apex locator under controlled clinical conditions", Endod Dent Traumatol, 1, pp.142~145 (1985)
- Topuz O, "Accuracy of two apex-locating handpieces in detecting simulated vertical and horizontal root fractures", J Endod, 34, pp.310~313 (2008)
- Angwaravong O, "Accuracy of an electronic apex locator in primary teeth with root resorption", Int Endod J, 42, pp.115~121 (2009)
- Goldberg F, "The evaluation of four electronic apex locators in teeth with simulated horizontal oblique root fractures", J Endod, 34, pp.1497~1499 (2008)
- Gordon MP, "Electronic apex locators", Int Endod J, 37, pp.425~437 (2004)
- Nahmias Y, "Expanded use of the electronic canal length measuring devices", J Endod, 9, pp.347~349 (1983)
- Fuss Z, "Determination of location of root perforations by electronic apex locators", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 82, pp.324~329 (1996)
- Kim DW, "Development of a frequencydependent- type apex locator with automatic compensation", Crit Rev Biomed Eng, 28, pp.473~479 (2000)
- Jenkins JA, "An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants", J Endod, 27, pp.209~211 (2001)
- Kaufman AY, "Accuracy of a new apex locator: an in vitro study", Int Endod J, 35, pp.186~192 (2002)
- Jeansonne MJ, "A comparison of 2.0% chlorhexidine gluconate and 5.25% sodium hypochlorite as antimicrobial endodontic irrigants", J Endod, 20, pp.276~278 (1994)
- Siqueira JF Jr, "Intracanal medicaments: evaluation of the antibacterial effects of chlorhexidine, metronidazole, and calcium hydroxide associated with three vehicles", J Endod, 23, pp.167~169 (1997)
- Mohammadi Z, "The properties and applications of chlorhexidine in endodontics", Int Endod J, 42, pp.288~302 (2009)
- Kaufman AY, "Hypersensitivity to sodium hypochlorite", J Endod, 15, pp.224~226 (1989)
- Dametto FR, "In vitro assessment of the immediate and prolonged antimicrobial action of chlorhexidine gel as an endodontic irrigant against Enterococcus faecalis", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 99, pp.768~772 (2005)
- Mônika CM, "A scaning electron microscopic evaluation of different root canal irrigation regimens", Braz Oral Res, 20, pp.235~240 (2006)
- Vianna ME, "In vitro evaluation of the antimicrobial activity of chlorhexidine and sodium hypochlorite", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 97, pp.79~84 (2004)
- Joesten MD, "The world of chemistry: essentials 4th ed", pp.461~ (2004), Brooks Cole
- Donnelly JC, "A simplified model to demonstrate the operation of electronic root canal measuring devices", J Endod, 19, pp.579~580 (1993)
- Ingle JI, "Endodontics 5th ed", pp.747~ (2002), Williams & Wilkins
- Kim M, "Effect on the healing of periapical perforations in dogs of the addition of growth factors to calcium hydroxide", J Endod, 27, pp.734~737 (2001)
- Ingle JI, "Ingle’s endodontics 6th ed", pp.852~853 (2008), Decker
- Ferry JD, "Viscoelastic Properties of Polymers 3rd ed", pp.529~ (1980), Wiley
- Erdemir A, "The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece", Int Endod J, 40, pp.391~397 (2007)
- Shabahang S, "An in vivo evaluation of Root ZX electronic apex locator", J Endod, 22, pp.616~618 (1996)
