Purpose: This pilot study was conducted to develop a novel test setup for the in vitro assessment of the primary stability of dental implants. This was achieved by characterising their long-term behaviour based on the continuous recording of micromotions resulting from dynamic and cyclic loading. Methods: Twenty screw implants, each 11 mm in length and either 3.8 mm (for premolars) or 4.3 mm (for molars) in diameter, were inserted into the posterior region of 5 synthetic mandibular models. Physiological masticatory loads were simulated by superimposing cyclic buccal-lingual movement of the mandible with a vertically applied masticatory force. Using an optical 3-dimensional (3D) measuring system, the micromotions of the dental crowns relative to the alveolar bone resulting from alternating off-centre loads were concurrently determined over 10,000 test cycles. Results: The buccal-lingual deflections of the dental crowns significantly increased from cycle 10 to cycle 10,000 (P<0.05). The deflections increased sharply during the first 500 cycles before approaching a plateau. Premolars exhibited greater maximum deflections than molars. The bone regions located mesially and distally adjacent to the loaded implants demonstrated deflections that occurred synchronously and in the same direction as the applied loads. The overall spatial movement of the implants over time followed an hourglassshaped loosening pattern with a characteristic pivot point 5.5±1.1 mm from the apical end. Conclusions: In synthetic mandibular models, the cyclic reciprocal loading of dental implants with an average masticatory force produces significant loosening. The evasive movements observed in the alveolar bone suggest that its anatomy and yielding could significantly influence the force distribution and, consequently, the mechanical behaviour of dental implants. The 3D visualisation of the overall implant movement under functional cyclic loading complements known methods and can contribute to the development of implant designs and surgical techniques by providing a more profound understanding of dynamic bone-implant interactions.

Abstract

Purpose: This pilot study was conducted to develop a novel test setup for the in vitro assessment of the primary stability of dental implants. This was achieved by characterising their long-term behaviour based on the continuous recording of micromotions resulting from dynamic and cyclic loading. Methods: Twenty screw implants, each 11 mm in length and either 3.8 mm (for premolars) or 4.3 mm (for molars) in diameter, were inserted into the posterior region of 5 synthetic mandibular models. Physiological masticatory loads were simulated by superimposing cyclic buccal-lingual movement of the mandible with a vertically applied masticatory force. Using an optical 3-dimensional (3D) measuring system, the micromotions of the dental crowns relative to the alveolar bone resulting from alternating off-centre loads were concurrently determined over 10,000 test cycles. Results: The buccal-lingual deflections of the dental crowns significantly increased from cycle 10 to cycle 10,000 (P<0.05). The deflections increased sharply during the first 500 cycles before approaching a plateau. Premolars exhibited greater maximum deflections than molars. The bone regions located mesially and distally adjacent to the loaded implants demonstrated deflections that occurred synchronously and in the same direction as the applied loads. The overall spatial movement of the implants over time followed an hourglassshaped loosening pattern with a characteristic pivot point 5.5±1.1 mm from the apical end. Conclusions: In synthetic mandibular models, the cyclic reciprocal loading of dental implants with an average masticatory force produces significant loosening. The evasive movements observed in the alveolar bone suggest that its anatomy and yielding could significantly influence the force distribution and, consequently, the mechanical behaviour of dental implants. The 3D visualisation of the overall implant movement under functional cyclic loading complements known methods and can contribute to the development of implant designs and surgical techniques by providing a more profound understanding of dynamic bone-implant interactions.

참고문헌 (39)

  1. Albrektsson T, "‘A requiem for the periodontal ligament’ revisited", Int J Prosthodont, 22, pp.120~122 (2009)
  2. Brånemark PI, "Intra-osseous anchorage of dental prostheses. I. Experimental studies", Scand J Plast Reconstr Surg, 3, pp.81~100 (1969)
  3. Monje A, "Relationship between primary", mechanical and secondary, Int J Oral Maxillofac Implants, pp.2019, 34[DOI]
  4. Roberts WE, "Bone dynamics of osseointegration, ankylosis, and tooth movement", J Indiana Dent Assoc, 78, pp.24~32 (1999)
  5. Raes F, "Immediate functional loading of single implants : a multicenter study with 4 years of follow-up", J Dent Res Dent Clin Dent Prospect, 12, pp.26~37 (2018)
  6. Douglas de Oliveira DW, "Dental implants with immediate loading using insertion torque of 30 Ncm : a systematic review", Implant Dent, 25, pp.675~683 (2016)
  7. Paepoemsin T, "Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading", Oral Implantol (Rome), 9, pp.213~221 (2016)
  8. Tsuruta K, "The influence of implant-abutment connection on the screw loosening and microleakage", Int J Implant Dent, 4, pp.11~17 (2018)
  9. Lee SY, "The effect of the thread depth on the mechanical properties of the dental implant", J Adv Prosthodont, 7, pp.115~121 (2015)
  10. Sennerby L, "Two different implant designs and impact of related drilling protocols on primary stability in different bone densities : an in vitro comparison study", Int J Oral Maxillofac Implants, 30, pp.564~568 (2015)
  11. Trisi P, "Implant micromotion is related to peak insertion torque and bone density", Clin Oral Implants Res, 20, pp.467~471 (2009)
  12. Freitas AC Jr, "The effect of implant design on insertion torque and immediate micromotion", Clin Oral Implants Res, 23, pp.113~118 (2012)
  13. Sugiura T, "Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants : an in vitro experiment and finite element analysis", J Periodontal Implant Sci, 47, pp.251~262 (2017)
  14. Mericske-Stern R, "Three-dimensional force measurements with mandibular overdentures connected to implants by ball-shaped retentive anchors. A clinical study", Int J Oral Maxillofac Implants, 13, pp.36~43 (1998)
  15. Fuentes R, "Systematic standardized and individualized assessment of masticatory cycles using electromagnetic 3D articulography and computer scripts", BioMed Res Int, 2017, pp.7134389~ (2017)
  16. Gratton DG, "Micromotion and dynamic fatigue properties of the dental implant-abutment interface", J Prosthet Dent, 85, pp.47~52 (2001)
  17. Steinebrunner L, "Implant-abutment interface design affects fatigue and fracture strength of implants", Clin Oral Implants Res, 19, pp.1276~1284 (2008)
  18. Khraisat A, "Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system", J Prosthet Dent, 91, pp.326~334 (2004)
  19. Winkler S, "Implant screw mechanics and the settling effect : overview", J Oral Implantol, 29, pp.242~245 (2003)
  20. Harder S, "Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration", Clin Oral Investig, 14, pp.427~432 (2010)
  21. Haïat G, "Effects of biomechanical properties of the bone-implant interface on dental implant stability : from in silico approaches to the patient’s mouth", Annu Rev Biomed Eng, 16, pp.187~213 (2014)
  22. Gehrke SA, "Quasi-static strength and fractography analysis of two dental implants manufactured by direct metal laser sintering", Clin Implant Dent Relat Res, 20, pp.368~374 (2018)
  23. Bacchi A, "Loosening torque of Universal Abutment screws after cyclic loading : influence of tightening technique and screw coating", J Adv Prosthodont, 7, pp.375~379 (2015)
  24. Markarian RA, "Scanning electron microscopy analysis of the adaptation of single-unit screw-retained computer-aided design", computer-aided manufacture abutments after mechanical cycling, 2018, pp.33, 127~136
  25. Dixon DL, "Comparison of screw loosening, rotation, and deflection among three implant designs", J Prosthet Dent, 74, pp.270~278 (1995)
  26. Barth T, "Implantate unter prothetischer Funktion", Implantologie, 69, pp.890~901 (2018)
  27. Anglin C, "Mechanical testing of shoulder prostheses and recommendations for glenoid design", J Shoulder Elbow Surg, 9, pp.323~331 (2000)
  28. Morneburg TR, "Measurement of masticatory forces and implant loads : a methodologic clinical study", Int J Prosthodont, 15, pp.20~27 (2002)
  29. Morneburg TR, "In vivo forces on implants influenced by occlusal scheme and food consistency", Int J Prosthodont, 16, pp.481~486 (2003)
  30. Kampe T, "Occlusal perception and bite force in young subjects with and without dental fillings", Acta Odontol Scand, 45, pp.101~107 (1987)
  31. Bates JF, "Masticatory function-a review of the literature. III. Masticatory performance and efficiency", J Oral Rehabil, 3, pp.57~67 (1976)
  32. Raghavendra S, "Early wound healing around endosseous implants : a review of the literature", Int J Oral Maxillofac Implants, 20, pp.425~431 (2005)
  33. Steinebrunner L, "In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems", Int J Oral Maxillofac Implants, 20, pp.875~881 (2005)
  34. Roberts EE, "Fracture resistance of titanium-based lithium disilicate and zirconia implant restorations", J Prosthodont, 27, pp.644~650 (2018)
  35. Heilemann M, "A novel micromotion measurement method to gain instructive insight into the acetabular bone-implant interface", Med Eng Phys, 86, pp.138~145 (2020)
  36. Kim YS, "Primary stability and self-tapping blades : biomechanical assessment of dental implants in medium-density bone", Clin Oral Implants Res, 22, pp.1179~1184 (2011)
  37. Hsu JT, "Impacts of 3D bone-to-implant contact and implant diameter on primary stability of dental implant", J Formos Med Assoc, 116, pp.582~590 (2017)
  38. Knöfler W, "Beobachtung an 10. 000 Implantaten über 20 Jahre-Eine retrospektive Studie. Einfluss von Alter, Geschlecht und Anatomie", Implantologie, 24, pp.1~13 (2016)
  39. Tokmakidis K, "Load distribution and loading concepts on teeth and implants", Z Zahnärztliche Impl, 25, pp.44~52 (2009)

관련 논문AI추천

Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysisKazuhiko Yamamoto, Kazuhiro Murakami, Sadami Tsutsumi, Satoshi Horita, Tadaaki Kirita, Tsutomu Sugiura대한치주과학회 · Journal of Periodontal & Implant Science2017 · 제47권 제4호The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysisKazuhiko Yamamoto, Kazuhiro Murakami, Sadami Tsutsumi, Satoshi Horita, Tadaaki Kirita, Tsutomu Sugiura대한치주과학회 · Journal of Periodontal & Implant Science2016 · 제46권 제3호In-vitro development of a temporal abutment screw to protect osseointegration in immediately loaded implantsHerminio Garcia-Roncero, Jordi Caballe-Serrano, Jordi Cano-Batalla, Josep Cabratosa-Termes, Oscar Figueras-Alvarez대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제2호The effect of the thread depth on the mechanical properties of the dental implant김성준, 김현승, 노경호, 박광범, 안현욱, 이선영, 하동국대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제2호Load response of the natural tooth and dental implant: A comparative biomechanics studyAndrea Gatti, Dale Robinson, David Ackland, Jaafar Abduo, Luis Aguilar, Peter Vee Sin Lee대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제3호Primary stability of implants with peri-implant bone defects of various widths: an in vitro investigation허익, 신승윤, 신승일, 임현진, 임현창, 정종혁, 홍지연대한치주과학회 · Journal of Periodontal & Implant Science2019 · 제49권 제1호

이 간행물의 다른 논문 (6건)