Investigation of the corrosion factor to the global strength of aging offshore jacket platforms under different marine zones
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This paper investigates the corrosion factor to the global strength of aging offshore jacket platforms in different marine zones. The time-dependent corrosion wastage model from Melchers, an active corrosion expert, by considering different marine zones, i.e., atmospheric, splash, and immersion. In addition, three aged jacket platform models of the originally installed platform were selected to investigate the effect of corrosion wastage on global strength. The jacket platform's global strength is calculated by the Reserve Strength Ratio (RSR) value. RSR is obtained via nonlinear static pushover analysis and is always used to estimate overall structure strength reserves. Safety assessment is evaluated by the PETRONAS Technical Standard (PTS). According to this study, immersion zone corrosion is the most influential zone after splash zone corrosion. Furthermore, the study also predicts the lifetime of each jacket platform, and it is useful for structural engineers to estimate corrosion allowance at the early design stage.
Abstract
This paper investigates the corrosion factor to the global strength of aging offshore jacket platforms in different marine zones. The time-dependent corrosion wastage model from Melchers, an active corrosion expert, by considering different marine zones, i.e., atmospheric, splash, and immersion. In addition, three aged jacket platform models of the originally installed platform were selected to investigate the effect of corrosion wastage on global strength. The jacket platform's global strength is calculated by the Reserve Strength Ratio (RSR) value. RSR is obtained via nonlinear static pushover analysis and is always used to estimate overall structure strength reserves. Safety assessment is evaluated by the PETRONAS Technical Standard (PTS). According to this study, immersion zone corrosion is the most influential zone after splash zone corrosion. Furthermore, the study also predicts the lifetime of each jacket platform, and it is useful for structural engineers to estimate corrosion allowance at the early design stage.
참고문헌 (54)
- Shehata E. Abdel Raheem, "NONLINEAR ANALYSIS OF OFFSHORE STRUCTURES UNDER WAVE LOADINGS", JES. Journal of Engineering Sciences, 40(3), pp.673~687 (2012), Egypts Presidential Specialized Council for Education and Scientific Research[DOI]
- Ahmad, Z., "Principles of Corrosion Engineering and Corrosion Control, Principles of Corrosion Engineering and Corrosion Control" (2006), Elsevier Ltd
- American Bureau of Shipping, "GUIDE FOR BUILDING AND CLASSING FLOATING PRODUCTION INSTALLATIONS", Production, ~ (2010)
- American Petroleum Institute, "API Recommended Practice 2A-WSD : Planning, Designing, and Constructing Fixed Offshore PlatformsdWorking Stress Design" (2014), Information Handling Services
- Australian, "New Zealand Standard", Australian, Wind actions, pp.2002, ~
- Nurul Uyun Azman, "Structural Integrity of Fixed Offshore Platforms by Incorporating Wave-in-Deck", Journal of Marine Science and Engineering, 9(9), pp.1027~ (2021), MDPI AG[DOI]
- Yong Bai, "Reassessment of the jacket structure due to uniform corrosion damage", Ships and Offshore Structures, pp.1~8 (2015), Informa UK Limited[DOI]
- Bentley Systems, "SACS User Manual Collapse", Release Version 14.3, ~ (2020)
- Bentley Systems, "SACS User Manual Seastate", Release Version 14.3, ~ (2020)
- de Miranda Batista, E., "Tubular Structures XV", Proceedings of the 15th International Symposium on Tubular Structures, pp.27~29 (2015)
- Ayoub Dehghani, "A review on defects in steel offshore structures and developed strengthening techniques", Structures, 20, pp.635~657 (2019), Elsevier BV[DOI]
- Wenbin Dong, "Fatigue reliability analysis of the jacket support structure for offshore wind turbine considering the effect of corrosion and inspection", Reliability Engineering & System Safety, 106, pp.11~27 (2012), Elsevier BV[DOI]
- El-Reedy, M. A., "Offshore Structures: Design, Construction and Maintenance" (2012), Gulf Professional Publishing
- Ersdal, G., "Assessment of offshore structures for life extension", Proceedings of the International Conference on Offshore Mechanics and Arctic Engineering - OMAE, 5, pp.277~284 (2008)
- Fenton, J. D., "A fifth-order Stokes theory for steady waves", J. Waterw. Port, Coast. Ocean Eng, 111, pp.216~234 (1985)[DOI]
- Feng Fu, "Design of Offshore Structures", Design and Analysis of Tall and Complex Structures, pp.251~293 (2018), Elsevier[DOI]
- D. Guzonas, "Corrosion phenomena induced by supercritical water in Generation IV nuclear reactors", Structural Materials for Generation IV Nuclear Reactors, pp.105~152 (2017), Elsevier[DOI]
- A.B.M. Saiful Islam, "Review of offshore energy in Malaysia and floating Spar platform for sustainable exploration", Renewable and Sustainable Energy Reviews, 16(8), pp.6268~6284 (2012), Elsevier BV[DOI]
- Riaz Khan, "System-based calibration of offshore Malaysia environmental action factors for the ISO 19902 PETRONAS offshore fixed platforms", Journal of Marine Engineering & Technology, 19(2), pp.78~101 (2019), Informa UK Limited[DOI]
- Kharade, A. S., "Offshore engineering : an overview of types and loadings on structures", Int. J. Struct. Civil Eng. Res, 3 (2014)
- D.K. Kim, "Ultimate strength performance of bulk carriers with various corrosion additions", Ships and Offshore Structures, 10(1), pp.59~78 (2014), Informa UK Limited[DOI]
- Do Kyun Kim, "Ultimate strength prediction of T-bar stiffened panel under longitudinal compression by data processing: A refined empirical formulation", Ocean Engineering, 192, pp.106522~ (2019), Elsevier BV[DOI]
- Do Kyun Kim, "A technical review on ultimate strength prediction of stiffened panels in axial compression", Ocean Engineering, 170, pp.392~406 (2018), Elsevier BV[DOI]
- Kim, D. K., "Safety guidelines of ultimate hull girder strength for grounded container ships", Saf. Sci, 59, pp.46~54 (2013)
- Do Kyun Kim, "An advanced technique to predict time-dependent corrosion damage of onshore, offshore, nearshore and ship structures: Part I = generalisation", International Journal of Naval Architecture and Ocean Engineering, 12, pp.657~666 (2020), 대한조선학회[DOI]
- D.K. Kim, "Safety assessment of corroded jacket platform considering decommissioning event", INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 14(3), pp.4462~4485 (2017), Universiti Malaysia Pahang Publishing[DOI]
- R. E. Melchers, "Modeling of Marine Immersion Corrosion for Mild and Low-Alloy Steels—Part 1: Phenomenological Model", CORROSION, 59(4), pp.319~334 (2003), Association for Materials Protection and Performance (AMPP)[DOI]
- Robert E. Melchers, "Corrosion uncertainty modelling for steel structures", Journal of Constructional Steel Research, 52(1), pp.3~19 (1999), Elsevier BV[DOI]
- Mohd Hairil Mohd, "A time-variant corrosion wastage model for subsea gas pipelines", Ships and Offshore Structures, 9(2), pp.161~176 (2013), Informa UK Limited[DOI]
- Mohd Hairil Mohd, "Residual strength of corroded subsea pipelines subject to combined internal pressure and bending moment", Ships and Offshore Structures, pp.1~11 (2015), Informa UK Limited[DOI]
- Mohd, M. H., "The Effect of Corrosion Depth on the Ultimate Strength of an Aging Fixed Offshore Structure BT - Design in Maritime Engineering", pp.271~286 (2022), Springer International Publishing
- M. Hairil Mohd, "Investigation of the corrosion progress characteristics of offshore subsea oil well tubes", Corrosion Science, 67, pp.130~141 (2013), Elsevier BV[DOI]
- M.H. Mohd, "Ultimate bending capacity of aged fixed platform by considering the effect of marine fouling", Latin American Journal of Solids and Structures, 16(5) (2019), FapUNIFESP (SciELO)[DOI]
- A.W. Momber, "Quantitative performance assessment of corrosion protection systems for offshore wind power transmission platforms", Renewable Energy, 94, pp.314~327 (2016), Elsevier BV[DOI]
- Musabikha, S., "Corrosion in the marine renewable energy : a review", Int. J. Environ. Res. Clean Energy, 7, pp.1~9 (2017)
- Jeom Kee Paik, "Advanced method for the development of an empirical model to predict time-dependent corrosion wastage", Corrosion Science, 63, pp.51~58 (2012), Elsevier BV[DOI]
- J.K. Paik, "Modified Paik–Mansour formula for ultimate strength calculations of ship hulls", Ships and Offshore Structures, 8(3-4), pp.245~260 (2013), Informa UK Limited[DOI]
- Jeom Kee Paik, "Probabilistic corrosion rate estimation model for longitudinal strength members of bulk carriers", Ocean Engineering, 25(10), pp.837~860 (1998), Elsevier BV[DOI]
- Jeom Kee Paik, "A Time-Dependent Corrosion Wastage Model for the Structures of Single-and Double-Hull Tankers and FSOs and FPSOs", Marine Technology and SNAME News, 40(03), pp.201~217 (2003), The Society of Naval Architects and Marine Engineers[DOI]
- Jeom Kee Paik, "A time-dependent corrosion wastage model for seawater ballast tank structures of ships", Corrosion Science, 46(2), pp.471~486 (2004), Elsevier BV[DOI]
- Petronas, "Design of Fixed Offshore Structures(Working Stress Design)" (2012), PETRONAS
- Potty, N. S., "Structural Integrity Management for fixed offshore platforms in Malaysia. World Acad. Sci", Eng. Technol, 58, pp.1079~ (2009)[DOI]
- R. Rolfes, "Sensing solutions for assessing and monitoring wind turbines", Sensor Technologies for Civil Infrastructures, pp.565~604 (2014), Elsevier[DOI]
- Beverley F Ronalds, "Environmental load distributions: influence of platform configuration", Journal of Constructional Steel Research, 59(2), pp.215~231 (2003), Elsevier BV[DOI]
- Jung Kwan Seo, "A risk-based inspection planning method for corroded subsea pipelines", Ocean Engineering, 109, pp.539~552 (2015), Elsevier BV[DOI]
- Karan Sotoodeh, "Subsea check valves", Subsea Valves and Actuators for the Oil and Gas Industry, pp.185~220 (2021), Elsevier[DOI]
- Stacey, A., "Life extension issues for ageing offshore installations", Proceedings of the International Conference on Offshore Mechanics and Arctic Engineering - OMAE, 5, pp.199~215 (2008)
- A. Stacey, "Safety factor requirements for the offshore industry", Engineering Failure Analysis, 14(3), pp.442~458 (2007), Elsevier BV[DOI]
- Thanh-Tuan Tran, "Development of a 3-legged jacket substructure for installation in the southwest offshore wind farm in South Korea", Ocean Engineering, 246, pp.110643~ (2022), Elsevier BV[DOI]
- Vu, V. T., "Hull girder ultimate strength assessment considering local corrosion", J. Mar. Sci. Appl, 19, pp.693~704 (2020)[DOI]
- Mohamed Mubarak Abdul Wahab, "Condition Assessment Techniques for Aged Fixed-Type Offshore Platforms Considering Decommissioning: a Historical Review", Journal of Marine Science and Application, 19(4), pp.584~614 (2020), Springer Science and Business Media LLC[DOI]
- Yang Yang, "Seismic Collapse Performance of Jacket Offshore Platforms with Time-Variant Zonal Corrosion Model", Applied Ocean Research, 84, pp.268~278 (2019), Elsevier BV[DOI]
- Yang Yang, "Collapse safety reserve of jacket offshore platforms subjected to rare intense earthquakes", Ocean Engineering, 131, pp.36~47 (2017), Elsevier BV[DOI]
- Zve, E. S., "Effect of zoning corrosion on the life-time structural reliability of a jacket offshore structure", Proceedings of the International Offshore and Polar Engineering Conference 2015, pp.419~426 (2015)