Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구
Clinical and radiological comparison between titanium and biodegradableminiplate monocortical osteosynthesis in mandibular angle fractures
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Abstract
The treatment objective of mandibular fracture is a return to normal function. According to Champy, a rigid fixation of mandibular angle fracture is performed by using 4 or 6 holes titanium miniplates on the external oblique ridge of mandible. However, the limitations of metal plate such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy due to the lack of normal stress reaction of the bone have been reported. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite its lower strength than that of the titanium plate and the side effect caused by the resorption in the body. In this study, 61 patients diagnosed as mandibular angle fracture and treated from Jan. 1998 to Dec. 2004 in our department have been reviewed. Metal plate fixation was used in 50 patients and biodegradable plate fixation in 11 patients on the external oblique ridge around the fractured mandibular angle according to the principle of monocortical osteosynthesis by Champy. We compared the incidence of side effects and the degree of bony union at the mandibular inferior border in two different fixation methods. In conclusion, we have found that one miniplate regardless of matter could provide enough strength to grasp bony fragments of the tension site and compress the inferior border of mandible without any complications.
참고문헌 (12)
- "Osteosynthesis with miniaturizedscrewed plates in maxillofacial surgery", 1, pp.79~84 (1973)
- ":Mandibular osteosynthesisby miniaturized screw plate via a buccal approach", 6, pp.14~21
- "Die Ergebnisse derMiniplattenosteosynthese bei 1000 Unterkieferfrakturen in der Kolnerund Stra burger Klinik", pp.363~366 (1983)
- "Comparison ofabsorbable self-reinforced multilayer poly-1-Lactide and metallicplates for the fixation of mandibular body osteotomies", 50, pp.255~262 (1992)
- "Tissue response to titanium plates:Atransmitted electron microscopic study", 55, pp.322~326 (1997)
- "Computer study ofbiodegradable plates for internal fixation of mandibular angle fractures", 59, pp.404~407 (2001)
- "Treatment of Mandible Fractures UsingBioabsorbable Plates:Preliminary Study", 27, pp.570~575 (2001)
- "The possible role of corrosionin inhibiting the healing of a mandibular fracture:report of acase", 39, pp.140~ (1981)
- "Electrolysis and stainless steel in bone", 38b, pp.745~ (1956)
- "Malignant fibrous histiocytoma of bone at thesite of a total hip arthroplasty", 66b, pp.38~ (1984)
- "Use of intraosseous metal appliancesin fixation of mandibular fractures"
- "A Comparative in vitrostudy on fixation of sagittal split osteotoies with Wurzburg screws"
