본문 바로가기
KERD
논문KCI 등재

Comparison of resorbable plates and titanium plates for fixatio stability of combined mandibular symphysis and angle fractures

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: We compared resorbable plates with titanium plates for treatment of combined mandibular angle and symphyseal fractures.Materials and Methods: Patients with mandibular angle and symphysis fractures were divided into two groups. The control (T) group received tita-nium plates while the experimental (R) group received resorbable plates. All procedures were carried out under general anesthesia using standard surgi-cal techniques. We compared the frequency of wound dehiscence, development of infection, malocclusion, malunion, screw breakage, and any other technical difficulties between the two groupsResults: Thirteen patients were included in the R group, where 39 resorbable plates were applied. The T group consisted of 16 patients who received 48 titanium plates. The mean age in the R and T groups was 28.29 and 24.23 years, respectively. Primary healing of the fractured mandible was ob-tained in all patients in both groups. Postoperative complications were minor and transient. Moreover, there were no significantdifferences in the rates of various complications between the two groups. Breakage of 3 screws during the perioperative period was seen in the R group, while no screws or plates were broken in the T group.Conclusion: Resorbable plates can be used to stabilize combined mandibular angle and symphysis fractures.

Abstract

Objectives: We compared resorbable plates with titanium plates for treatment of combined mandibular angle and symphyseal fractures.Materials and Methods: Patients with mandibular angle and symphysis fractures were divided into two groups. The control (T) group received tita-nium plates while the experimental (R) group received resorbable plates. All procedures were carried out under general anesthesia using standard surgi-cal techniques. We compared the frequency of wound dehiscence, development of infection, malocclusion, malunion, screw breakage, and any other technical difficulties between the two groupsResults: Thirteen patients were included in the R group, where 39 resorbable plates were applied. The T group consisted of 16 patients who received 48 titanium plates. The mean age in the R and T groups was 28.29 and 24.23 years, respectively. Primary healing of the fractured mandible was ob-tained in all patients in both groups. Postoperative complications were minor and transient. Moreover, there were no significantdifferences in the rates of various complications between the two groups. Breakage of 3 screws during the perioperative period was seen in the R group, while no screws or plates were broken in the T group.Conclusion: Resorbable plates can be used to stabilize combined mandibular angle and symphysis fractures.

참고문헌 (20)

  1. Ellis E 3rd, "Ten years of mandibular fractures: an analysis of 2,137 cases", Oral Surg Oral Med Oral Pathol, 59, pp.120~129 (1985)
  2. Haug RH, "An epidemiologic survey of facial fractures and concomitant injuries", J Oral Maxillofac Surg, 48, pp.926~932 (1990)
  3. Tuovinen V, "A retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium miniplates", J Oral Maxillofac Surg, 52, pp.931~935 (1994)
  4. Kim YK, "Tissue response to titanium plates: a transmitted electron microscopic study", J Oral Maxillofac Surg, 55, pp.322~326 (1997)
  5. Suuronen R, "Bioabsorbable plates and screws: current state of the art in facial fracture repair", J Craniomaxillofac Trauma, 6, pp.19~27 (2000)
  6. Leonhardt H, "INION compared with titanium osteosynthesis: a prospective investigation of the treatment of mandibular fractures", Br J Oral Maxillofac Surg, 46, pp.631~634 (2008)
  7. 최은주, "Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구", 대한구강악안면외과학회지, 32(3), pp.222~225 (2006), 대한구강악안면외과학회
  8. 정종철, "악안면 골절 치료시 흡수성 고정판의 사용에 관한 임상 연구", 대한구강악안면외과학회지, 29(6), pp.438~443 (2003), 대한구강악안면외과학회
  9. Kim YK, "Treatment of mandible fractures using bioabsorbable plates", Plast Reconstr Surg, 110, pp.25~31 (2002)
  10. Champy M, "Mandibular osteosynthesis by miniature screwed plates via a buccal approach", J Maxillofac Surg, 6, pp.14~21 (1978)
  11. Bos RR, "Bio-absorbable plates and screws for internal fixation of mandibular fractures. A study of six dogs", Int J Oral Maxillofac Surg, 18, pp.365~369 (1989)
  12. 김영균, "Application of Bioabsorbable Plates in Orthognathic Surgery", 대한구강악안면외과학회지, 32(1), pp.60~64 (2006), 대한구강악안면외과학회
  13. Bessho K, "A bioabsorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery", J Oral Maxillofac Surg, 55, pp.941~945 (1997)
  14. Kallela I, "Fixation of mandibular body osteotomies using biodegradable amorphous self-reinforced (70L:30DL) polylactide or metal lag screws: an experimental study in sheep", J Craniomaxillofac Surg, 27, pp.124~133 (1999)
  15. Wittwer G, "Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis?", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 101, pp.419~425 (2006)
  16. Bayram B, "Comparison of fixation stability of resorbable versus titanium plate and screws in mandibular angle fractures", J Oral Maxillofac Surg, 67, pp.1644~1648 (2009)
  17. Esen A, "Comparison of stability of titanium and absorbable plate and screw fixation for mandibular angle fractures", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 106, pp.806~811 (2008)
  18. Ellis E 3rd, "Open reduction and internal fixation of combined angle and body", symphysis fractures of the mandible: how much fixation is enough?, 2013, pp.71, 726~733
  19. Fonseca RJ, "Oral and Maxillofacial Trauma. Vol 2" (1997), WB saunders
  20. Ahmed W, "Bioresorbable versus titanium plates for mandibular fractures", J Coll Physicians Surg Pak, 23, pp.480~483 (2013)