Abstract
In an open reduction of the mandibular angle fracture, it is crucial to approximate each fracture segment as closer as possible for the reduction of the healing period. In this case report, we proposed a new technique for the mandibular angle fracture. This was designed to minimize the gap between two separated segments using mini-implants and surgical wires. Mini-implants were placed around the fracture line, followed by wire ligation to minimize the fracture gap. And then internal fixation was easily employed with plates and screws. The advantages of this technique were reduced time for operation, the promotion of healing, rapid functional recovery, and few complications.
참고문헌 (10)
- "골절 정복 겸자가 하악골 골절정복에 미치는 효과에 관한 광탄성 연구", 28, pp.464~471 (2002)
- "Non-union of the mandible", pp.908~920
- "Osteosynthesis in facial bone fractures using miniplates", pp.810~813
- "A three-dimensional study of bending and torsion moments for different fracture sites in the mandible: an in vitro study", 26, pp.383~388 (1997)
- "관혈적 정복술로 치료한 하악골 골절에 서의 합병증", 27(5), pp.474~480 (2001)
- "Prognosis of teeth involved in the line of mandibular fractures"
- "Treatmenr of mandibular fractures using two non-compression miniplates", pp.1032~1036
- "The use of miniplates in mandibular fractures An in vitro study"
- "Stability testing of a two miniplate fixation technique for mandibular angle fractures. An in vitro study", 23, pp.122~125 (1995)
- "Rigid fixation of facial fratures in", pp.1206~1240 (1991)