Long-Term Results of Total Hip Arthroplasty with an Extensively Porous Coated Stem in Patients Younger than 45 Years Old
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: This study analyzed the long-term results of cementless total hip arthroplasty using an extensively porous coated stem in patients younger than 45 years old. Materials and Methods: The clinical and radiographic results of 45 hips from 38 patients who underwent cementless total hip replacement arthroplasty with an AML prosthesis were reviewed retrospectively. The average follow-up was 12 years (range, 10-15 years). Results: The average Harris hip score at the time of final follow-up was 87.3 (range 77-94) points. Forty two hips (93.3%) showed excellent and good clinical results. Osteolysis occurred around the stem in 20 hips (44.4%) and around the cup in 26hips (57.8%). Stress-mediated femoral resorption was observed in 33 hips (73.3%) at 10 years. There was no incidence of resorption progressing after 5 years postoperatively. There was no stem loosening. Five hips were revised for osteolysis, cup loosening and polyethylene wear. Conclusion: The long term results of total hip arthroplasty using an extensively porous coated stem were acceptable, and there was no case involving the progression of proximal bone resorption.
Abstract
Purpose: This study analyzed the long-term results of cementless total hip arthroplasty using an extensively porous coated stem in patients younger than 45 years old. Materials and Methods: The clinical and radiographic results of 45 hips from 38 patients who underwent cementless total hip replacement arthroplasty with an AML prosthesis were reviewed retrospectively. The average follow-up was 12 years (range, 10-15 years). Results: The average Harris hip score at the time of final follow-up was 87.3 (range 77-94) points. Forty two hips (93.3%) showed excellent and good clinical results. Osteolysis occurred around the stem in 20 hips (44.4%) and around the cup in 26hips (57.8%). Stress-mediated femoral resorption was observed in 33 hips (73.3%) at 10 years. There was no incidence of resorption progressing after 5 years postoperatively. There was no stem loosening. Five hips were revised for osteolysis, cup loosening and polyethylene wear. Conclusion: The long term results of total hip arthroplasty using an extensively porous coated stem were acceptable, and there was no case involving the progression of proximal bone resorption.
참고문헌 (18)
- Engh CA Sr, "Extensively porous-coated stems:avoiding modularity", Orthopedics, 31, pp.911~912 (2008)
- Engh CA, "Biological fixation in total hip arthroplasty", pp.135~189 (1985), Slack
- Engh CA, "Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty", J Bone Joint Surg Am, 79, pp.177~184 (1997)
- Hastings DE, "Sellenkowitsch M. Review of 10-year of results of PCA hip arthroplasty", Can J Surg, 41, pp.48~52 (1998)
- Kim YH, "Cementless porous-coated anatomic medullary locking total hip prosthesis", J Arthroplasty, 9, pp.243~252 (1994)
- Bobyn JD, "The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty", Clin Orthop Relat Res, pp.196~213 (1990)
- Claus AM, "Fracture of the greater trochanter induced by osteolysis with the anatomic inedullary locking prosthesis", J Arthroplasty, 17, pp.706~712 (2002)
- Engh CA, "The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty", Clin Orthop Relat Res, 231, pp.7~28 (1988)
- Engh CA, "Porous coated hip replacement. The factors governing bone ingrowth, stress shielding and clinical results", J Bone Joint Surg Br, 69, pp.45~54 (1987)
- Kröger H, "Bone density at the proximal femur after total hip arthroplasty", Clin Orthop Relat Res, pp.66~74 (1998)
- Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fracture: Treatment by mold arthroplasty", J Bone Joint Surg Am, 51, pp.737~755 (1969)
- Gruen TA, "Radiographic criteria for the clinical performance of uncemented total joint replacements In Quantitative characterization and performance of porous implants for hard tissue applications", American society for Testing and Materials, Standards and Testing Protocols, 207~218 (1987)
- Livermore J, "Effect of femoral head size on wear of the polyethylene acetabular component", J Bone Joint Surg Am, 72, pp.518~528 (1990)
- Kim YH, "Cementless total hip arthroplasty in patients with osteonecrosis of the femoral head", Clin Orthop Relat Res, pp.73~84 (1995)
- Engh CA, "Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components", Clin Orthop Relat Res, pp.107~128 (1990)
- DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, pp.20~32 (1976)
- Schulte KR, "The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon", J Bone Joint Surg Am, 75, pp.961~975 (1993)
- Engh CA Jr, "Clinical consequence of stress shielding after porous coated total hip arthroplasty", Clin Orthop Relat Res, pp.157~163 (2003)
