Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the Bencox hip stem–the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the Bencox hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem–both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the Bencox hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.
Abstract
Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the Bencox hip stem–the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the Bencox hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem–both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the Bencox hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.
참고문헌 (26)
- Learmonth ID, "The operation of the century : total hip replacement", Lancet, 370, pp.1508~1519 (2007)
- Banaszkiewicz PA., "Classic Papers in Orthopaedics", pp.39~41 (2014), Springer
- Rothman RH, "Cemented versus cementless total hip arthroplasty. A critical review", Clin Orthop Relat Res, (254), pp.153~169 (1990)
- Malik A, "Impingement with total hip replacement", J Bone Joint Surg Am, 89, pp.1832~1842 (2007)
- Kim S, "Focal peliosis hepatis as a mimicker of hepatic tumors : radiologicalpathological correlation", J Comput Assist Tomogr, 31, pp.79~85 (2007)
- 김정택, "Implant Design in Cementless Hip Arthroplasty", Hip and Pelvis, 28(2), pp.65~75 (2016), 대한고관절학회[DOI]
- Lim Y, "A simple method using a PACS to minimize leg length discrepancy in primary THA : a method to minimize leg length discrepancy", J Arthroplasty, 28, pp.1791~1795 (2013)
- Bourne RB, "Soft tissue balancing: the hip", J Arthroplasty, 17(4 Suppl 1), pp.17~22 (2002)
- Masonis JL, "Surgical approach, abductor function, and total hip arthroplasty dislocation", Clin Orthop Relat Res, (405), pp.46~53 (2002)
- 이중명, "Wiring Techniques for the Fixation of Trochanteric Fragments during Bipolar Hemiarthroplasty for Femoral Intertrochanteric Fracture: Clinical Study and Technical Note", Hip and Pelvis, 29(1), pp.44~53 (2017), 대한고관절학회[DOI]
- Banaszkiewicz PA., "Classic Papers in Orthopaedics", pp.105~107 (2014), Springer
- Chan KC, "Cemented hemiarthroplasties for elderly patients with intertrochanteric fractures", Clin Orthop Relat Res, (371), pp.206~215 (2000)
- von Roth P, "Cemented bipolar hemiarthroplasty provides definitive treatment for femoral neck fractures at 20 years and beyond", Clin Orthop Relat Res, 473, pp.3595~3599 (2015)
- Hong CC, "Cemented hemiarthroplasty in traumatic displaced femoral neck fractures and deep vein thrombosis: is there really a link?", Singapore Med J, 57, pp.69~72 (2016)
- Stauffer RN., "Ten-year follow-up study of total hip replacement", J Bone Joint Surg Am, 64, pp.983~990 (1982)
- Sutherland CJ, "A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties", J Bone Joint Surg Am, 64, pp.970~982 (1982)
- Bourne RB, "Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis. A five-year follow-up study", J Bone Joint Surg Am, 76, pp.1464~1470 (1994)
- Lavernia C, "Thigh pain in primary total hip arthroplasty: the effects of elastic moduli", J Arthroplasty, 19(7 Suppl 2), pp.10~16 (2004)
- 이중명, "Bencox® Hip Stem을 이용한 인공 고관절 치환술의 최소 5년 추시 결과", 대한정형외과학회지, 49(2), pp.126~132 (2014), 대한정형외과학회
- Cruz-Pardos A, "Total hip arthroplasty with use of the cementless Zweymüller Alloclassic System : A concise follow-up, at a minimum of 25 years, of a previous report", J Bone Joint Surg Am, 99, pp.1927~1931 (2017)
- 이중명, "Cementless Spotorno (CLS) 대퇴 스템을 사용한 인공 고관절 치환술의 15년-20년 추시 결과", 대한정형외과학회지, 43(6), pp.710~717 (2008), 대한정형외과학회
- Müller LA, "Seventeen-year survival of the cementless CLS Spotorno stem", Arch Orthop Trauma Surg, 130, pp.269~275 (2010)
- Haentjens P, "Treatment of unstable intertrochanteric and subtrochanteric fractures in elderly patients. Primary bipolar arthroplasty compared with internal fixation", J Bone Joint Surg Am, 71, pp.1214~1225 (1989)
- Barrack RL, "Current status of trochanteric reattachment in complex total hip arthroplasty", Clin Orthop Relat Res, 441, pp.237~242 (2005)
- Koyama K, "Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplasty", J Orthop Sci, 6, pp.22~27 (2001)
- Lim SJ, "High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems", Int Orthop, 39, pp.1689~1693 (2015)