Results of Hip Arthroplasty Using a COREN Stem at a Minimum of Ten Years
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: We report on the 10-year clinical hip function and radiologic outcomes of patients who underwent hip arthroplasty using a COREN stem. Materials and Methods: A consecutive series of 224 primary cementless hip arthroplasty implantations were performed using a COREN stem between 2009 and 2011; among these, evaluation of 128 hips was performed during a minimum follow-up period of 10 years. The mean age of patients was 65.4 years (range, 40-82 years) and the mean duration of follow-up was 10.8 years (range, 10-12 years). Evaluation of clinical hip function and radiologic implant outcomes was performed according to clinical score, thigh pain, and radiologic analysis. Results: Dramatic improvement of the mean Harris hip score (HHS) from 59.4 preoperatively to 93.5 was observed at the final follow-up (P≤0.01). Stable fixation was demonstrated for all implants with no change in position except for one case of Vancouver type B2 periprosthetic femur fracture. A radiolucent line (RLL) was observed in 16 hips (12.5%). Thigh pain was observed in only two hips (1.6%) at the final follow-up. There were no cases of osteolysis around the stem. The survival rate for the COREN stem was 97.7%. Conclusion: Good long-term survival with excellent clinical and radiological outcomes can be achieved using the COREN femoral stem regardless of Dorr type.
Abstract
Purpose: We report on the 10-year clinical hip function and radiologic outcomes of patients who underwent hip arthroplasty using a COREN stem. Materials and Methods: A consecutive series of 224 primary cementless hip arthroplasty implantations were performed using a COREN stem between 2009 and 2011; among these, evaluation of 128 hips was performed during a minimum follow-up period of 10 years. The mean age of patients was 65.4 years (range, 40-82 years) and the mean duration of follow-up was 10.8 years (range, 10-12 years). Evaluation of clinical hip function and radiologic implant outcomes was performed according to clinical score, thigh pain, and radiologic analysis. Results: Dramatic improvement of the mean Harris hip score (HHS) from 59.4 preoperatively to 93.5 was observed at the final follow-up (P≤0.01). Stable fixation was demonstrated for all implants with no change in position except for one case of Vancouver type B2 periprosthetic femur fracture. A radiolucent line (RLL) was observed in 16 hips (12.5%). Thigh pain was observed in only two hips (1.6%) at the final follow-up. There were no cases of osteolysis around the stem. The survival rate for the COREN stem was 97.7%. Conclusion: Good long-term survival with excellent clinical and radiological outcomes can be achieved using the COREN femoral stem regardless of Dorr type.
참고문헌 (27)
- Sanfilippo JA, "Implants for total hip arthroplasty", Expert Rev Med Devices, 3, pp.769~776 (2006)[DOI]
- Suckel A, "Longterm results for the uncemented Zweymuller", Alloclassic hip endoprosthesis. A 15-year minimum follow-up of 320 hip operations, 2009, pp.24, 846~853
- Korovessis P, "High medium-term survival of Zweymüller SLR-plus stem used in femoral revision", Clin Orthop Relat Res, 467, pp.2032~2040 (2009)[DOI]
- Korovessis P, "High medium-term survivorship and durability of Zweymüller-Plus total hip arthroplasty", Arch Orthop Trauma Surg, 131, pp.603~611 (2011)[DOI]
- 김희중, "Cementless Total Hip Arthroplasty Using the COREN Hip System: A Minimum Five-Year Follow-up Study", Hip and Pelvis, 30(3), pp.162~167 (2018), 대한고관절학회[DOI]
- Zweymüller KA, "Radiolucent lines and osteolysis along tapered straight cementless titanium hip stems : a comparison of 6-year and 10-year follow-up results in 95 patients", Acta Orthop, 77, pp.871~876 (2006)[DOI]
- 박윤수, "COREN HIP System을 이용한 무시멘트 고관절 전치환술", Hip and Pelvis, 19(4), pp.457~462 (2007), 대한고관절학회
- 김상민, "COREN Hip System을 이용한 무시멘트 고관절 전치환술의 최소 7년 추시 결과", Hip and Pelvis, 25(3), pp.173~181 (2013), 대한고관절학회[DOI]
- Lim YW, "Enhanced cell integration to titanium alloy by surface treatment with microarc oxidation : a pilot study", Clin Orthop Relat Res, 467, pp.2251~2258 (2009)[DOI]
- 이중명, "Bencox® Hip Stem을 이용한 인공 고관절 치환술의 최소 5년 추시 결과", 대한정형외과학회지, 49(2), pp.126~132 (2014), 대한정형외과학회
- Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fractures : treatment by mold arthroplasty. An endresult study using a new method of result evaluation", J Bone Joint Surg Am, 51, pp.737~755 (1969)
- Dorr LD, "Structural and cellular assessment of bone quality of proximal femur", Bone, 14, pp.231~242 (1993)[DOI]
- Engh CA, "The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty", Clin Orthop Relat Res, (231), pp.7~28 (1988)[DOI]
- Gruen TA, ""Modes of failure"of cemented stem-type femoral components : a radiographic analysis of loosening", Clin Orthop Relat Res, (141), pp.17~27 (1979)[DOI]
- Davies MS, "Migration of the uncemented CLS femoral component", Orthopedics, 22, pp.225~228 (1999)[DOI]
- Ström H, "Early migration pattern of the uncemented CLS stem in total hip arthroplasties", Clin Orthop Relat Res, 454, pp.127~132 (2007)[DOI]
- Kubo T, "Cementless Lord total hip arthroplasty : cup loosening common after minimum 10-year follow-up of 103 hips", Acta Orthop Scand, 72, pp.585~590 (2001)[DOI]
- 강준순, "Clinical and Radiological Outcomes of Rectangular Tapered Cementless Stem According to Proximal Femoral Geometry in Elderly Asian Patients", Hip and Pelvis, 31(4), pp.224~231 (2019), 대한고관절학회
- Belmont PJ Jr, "Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years. A concise follow-up of previous reports", J Bone Joint Surg Am, 90, pp.1524~1530 (2008)[DOI]
- Grant P, "Total hip arthroplasty with the Lord prosthesis. A long-term follow-up study", J Bone Joint Surg Am, 86, pp.2636~2641 (2004)[DOI]
- Vresilovic EJ, "Incidence of thigh pain after uncemented total hip arthroplasty as a function of femoral stem size", J Arthroplasty, 11, pp.304~311 (1996)[DOI]
- Engh CA, "Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results", J Bone Joint Surg Br, 69, pp.45~55 (1987)[DOI]
- Biemond JE, "Longterm survivorship analysis of the cementless Spotorno femoral component in patients less than 50 years of age", J Arthroplasty, 26, pp.386~390 (2011)[DOI]
- Müller LA, "Seventeen-year survival of the cementless CLS Spotorno stem", Arch Orthop Trauma Surg, 130, pp.269~275 (2010)[DOI]
- Keeling P, "Long-term survival of the cemented exeter universal stem in patients 50 years and younger : an update on 130 hips", J Arthroplasty, 35, pp.1042~1047 (2020)[DOI]
- Aldinger PR, "Survival of the cementless Spotorno stem in the second decade", Clin Orthop Relat Res, 467, pp.2297~2304 (2009)[DOI]
- Lim SJ, "High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless gritblasted tapered-wedge stems", Int Orthop, 39, pp.1689~1693 (2015)[DOI]
