Background: Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. The aim of this study was to investigate the relationship between changing common carotid artery Doppler measures and stroke volume (SV). We hypothesized that correlation between SV and carotid Doppler would improve with larger numbers of consecutively-averaged cardiac cycles. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: Using a wearable carotid Doppler ultrasound 73,431 cardiac cycles were compared to SV during central volume loss and resuscitation induced.

Abstract

Background: Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. The aim of this study was to investigate the relationship between changing common carotid artery Doppler measures and stroke volume (SV). We hypothesized that correlation between SV and carotid Doppler would improve with larger numbers of consecutively-averaged cardiac cycles. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: Using a wearable carotid Doppler ultrasound 73,431 cardiac cycles were compared to SV during central volume loss and resuscitation induced.

참고문헌 (25)

  1. Teboul JL, "Less invasive hemodynamic monitoring in critically ill patients", Intensive Care Med, 42, pp.1350~1359 (2016)
  2. Cheong I, "Carotid flow as a surrogate of the left ventricular stroke volume", J Clin Monit Comput, 37, pp.661~667 (2023)
  3. Kenny JS, "A theoretical foundation for relating the velocity time integrals of the left ventricular outflow tract and common carotid artery", J Clin Monit Comput, 37, pp.937~939 (2023)
  4. Kenny JS, "Carotid Doppler ultrasonography correlates with stroke volume in a human model of hypovolaemia and resuscitation : analysis of 48 570 cardiac cycles", Br J Anaesth, 127, pp.e60~e63 (2021)
  5. Kenny JS, "Temporal concordance between pulse contour analysis, bioreactance and carotid doppler during rapid preload changes", PLoS One, 17, pp.e0265711~ (2022)
  6. Barjaktarevic I, "Ultrasound assessment of the change in carotid corrected flow time in fluid responsiveness in undifferentiated shock", Crit Care Med, 46, pp.e1040~e1046 (2018)
  7. Marik PE, "The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients", Chest, 143, pp.364~370 (2013)
  8. Effat H, "Electrical cardiometry versus carotid Doppler in assessment of fluid responsiveness in critically ill septic patients", Egypt J Crit Care Med, 8, pp.96~113 (2021)
  9. Kimura A, "Changes in corrected carotid flow time induced by recruitment maneuver predict fluid responsiveness in patients undergoing general anesthesia", J Clin Monit Comput, 36, pp.1069~1077 (2022)
  10. Jung S, "Ability of carotid corrected flow time to predict fluid responsiveness in patients mechanically ventilated using low tidal volume after surgery", J Clin Med, 10, pp.2676~ (2021)
  11. Cheong I, "Passive leg raising test using the carotid flow velocity-time integral to predict fluid responsiveness", J Ultrasound (2023)[DOI]
  12. Douglas IS, "Fluid response evaluation in sepsis hypotension and shock : a randomized clinical trial", Chest, 158, pp.1431~1445 (2020)
  13. Dubin A, "Characteristics of resuscitation, and association between use of dynamic tests of fluid responsiveness and outcomes in septic patients : results of a multicenter prospective cohort study in Argentina", Ann Intensive Care, 10, pp.40~ (2020)
  14. Kenny JS, "A wireless ultrasound patch detects mild-to-moderate central hypovolemia during lower body negative pressure", J Trauma Acute Care Surg, 93(2S Suppl 1), pp.S35~S40 (2022)
  15. Abbasi A, "Change in carotid blood flow and carotid corrected flow time assessed by novice sonologists fails to determine fluid responsiveness in spontaneously breathing intensive care unit patients", Ultrasound Med Biol, 46, pp.2659~2666 (2020)
  16. van Houte J, "Correlation of carotid Doppler blood flow with invasive cardiac output measurements in cardiac surgery patients", J Cardiothorac Vasc Anesth, 36, pp.1081~1091 (2022)
  17. Khan S, "Carotid doppler indices do not predict fluid responsiveness in mechanically ventilated patients undergoing coronary artery bypass grafting surgery", J Card Surg, 37, pp.4418~4424 (2022)
  18. Kenny JS, "Carotid Doppler measurement variability in functional hemodynamic monitoring : an analysis of 17, 822 cardiac cycles", Crit Care Explor, 3, pp.e0439~ (2021)
  19. Bussmann BM, "Observational study in healthy volunteers to define interobserver reliability of ultrasound haemodynamic monitoring techniques performed by trainee doctors", Eur J Emerg Med, 26, pp.217~223 (2019)
  20. Kenny JS, "Carotid artery velocity time integral and corrected flow time measured by a wearable Doppler ultrasound detect stroke volume rise from simulated hemorrhage to transfusion", BMC Res Notes, 15, pp.7~ (2022)
  21. Kerrebijn I, "Correlation between changing carotid artery corrected flow time and ascending aortic Doppler flow velocity", Br J Anaesth, 131, pp.e192~e195 (2023)
  22. Kenny JS, "The Doppler shock index measured by a wearable ultrasound patch accurately detects moderate-to-severe central hypovolemia during lower body negative pressure", J Am Coll Emerg Physicians Open, 2, pp.e12533~ (2021)
  23. Kenny JS, "Minimizing measurement variability in carotid ultrasound evaluations", J Ultrasound Med, 40, pp.855~856 (2021)
  24. Kenny JS, "Timing and measurement variability are critical when using carotid Doppler to infer hemodynamics", Ultrasound Med Biol, 46, pp.3485~3486 (2020)
  25. Beier L, "Carotid ultrasound to predict fluid responsiveness : a systematic review", J Ultrasound Med, 39, pp.1965~1976 (2020)

관련 논문AI추천

Clinical decision guidance by an automated, brachial cuff-based cardiac output assessment in patients with shock under treatment: a pilot study in Athens, GreeceAntonios A. Argyris, Athanase D. Protogerou, Dimitrios Mouziouras, Dimitrios Xanthis, Elpida Athanasopoulou, Georgia Mastakoura, Panagiotis Kanatas, Pavlos Vernikos, Theodore G. Papaioannou대한중환자의학회 · Acute and Critical Care2025 · 제40권 제2호Performance evaluation of non-invasive cardiac output monitoring device (HemoVista) based on multi-channel thoracic impedance plethysmography technology박재희, 최병문대한중환자의학회 · Acute and Critical Care2024 · 제39권 제4호Measurement of mean systemic filling pressure after severe hemorrhagic shock in swine anesthetized with propofol-based total intravenous anesthesia: implications for vasopressor-free resuscitationChalkias Athanasios, Koutsovasilis Anastasios, Laou Eleni, Papalois Apostolos, Xanthos Theodoros대한중환자의학회 · Acute and Critical Care2020 · 제35권 제2호승압제를 사용하는 쇼크 환자에서 맥파전달시간을 이용한 비침습적혈압 측정에 대한 비교 연구박경남, 서상원, 성낙진, 성원영, 양영모, 양희범, 이장영, 홍성엽대한중환자의학회 · Acute and Critical Care2009 · 제24권 제1호자발 호흡을 유지하는 정상 성인에서 수동적 하지 거상법 시행 후 혈역학적 변화와 맥박 산소 측정기를 이용한 혈량 파형의 진폭 변이도 조사고재욱, 김인병, 문동석, 박요섭, 이교준, 정상원대한중환자의학회 · Acute and Critical Care2008 · 제23권 제1호Diagnostic accuracy of left ventricular outflow tract velocity time integral versus inferior vena cava collapsibility index in predicting post-induction hypotension during general anesthesia: an observational studyArti Sharma, Arvind Sethi, Jyoti Pathania, Vibhuti Sharma대한중환자의학회 · Acute and Critical Care2024 · 제39권 제1호

이 간행물의 다른 논문 (23건)