본문 바로가기
KERD
논문KCI 등재

Diagnostic accuracy of left ventricular outflow tract velocity time integral versus inferior vena cava collapsibility index in predicting post-induction hypotension during general anesthesia: an observational study

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: Point of care ultrasound (POCUS) is being explored for dynamic measurements like inferior vena cava collapsibility index (IVC-CI) and left ventricular outflow tract velocity time integral (LVOT-VTI) to guide anesthesiologists in predicting fluid responsiveness in the preoperative period and in treating post-induction hypotension (PIH) with varying accuracy.Methods: In this prospective, observational study on included 100 adult patients undergoing elective surgery under general anesthesia, the LVOT-VTI and IVC-CI measurements were performed in the preoperative room 15 minutes prior to surgery, and PIH was measured for 20 minutes in the post-induction period.Results: The incidence of PIH was 24%. The area under the curve, sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the two techniques at 95% confidence interval was 0.613, 30.4%, 93.3%, 58.3%, 81.4%, 73.6% for IVC-CI and 0.853, 83.3%, 80.3%, 57.1%, 93.8%, 77.4% for LVOT -VTI, respectively. In multivariate analysis, the cutoff value for IVC-CI was >51.5 and for LVOT-VTI it was ≤17.45 for predicting PIH with odd ratio [OR] of 8.491 (P=0.025) for IVCCI and OR of 17.427 (P<0.001) for LVOT. LVOT-VTI assessment was possible in all the patients, while 10% of patients were having poor window for IVC measurements.Conclusions: We recommend the use of POCUS using LVOT-VTI or IVC-CI to predict PIH, to decrease the morbidity of patients undergoing surgery. Out of these, we recommend LVOT-VTI measurements as it has showed a better diagnostic accuracy (77.4%) with no failure rate.

Abstract

Background: Point of care ultrasound (POCUS) is being explored for dynamic measurements like inferior vena cava collapsibility index (IVC-CI) and left ventricular outflow tract velocity time integral (LVOT-VTI) to guide anesthesiologists in predicting fluid responsiveness in the preoperative period and in treating post-induction hypotension (PIH) with varying accuracy.Methods: In this prospective, observational study on included 100 adult patients undergoing elective surgery under general anesthesia, the LVOT-VTI and IVC-CI measurements were performed in the preoperative room 15 minutes prior to surgery, and PIH was measured for 20 minutes in the post-induction period.Results: The incidence of PIH was 24%. The area under the curve, sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the two techniques at 95% confidence interval was 0.613, 30.4%, 93.3%, 58.3%, 81.4%, 73.6% for IVC-CI and 0.853, 83.3%, 80.3%, 57.1%, 93.8%, 77.4% for LVOT -VTI, respectively. In multivariate analysis, the cutoff value for IVC-CI was >51.5 and for LVOT-VTI it was ≤17.45 for predicting PIH with odd ratio [OR] of 8.491 (P=0.025) for IVCCI and OR of 17.427 (P<0.001) for LVOT. LVOT-VTI assessment was possible in all the patients, while 10% of patients were having poor window for IVC measurements.Conclusions: We recommend the use of POCUS using LVOT-VTI or IVC-CI to predict PIH, to decrease the morbidity of patients undergoing surgery. Out of these, we recommend LVOT-VTI measurements as it has showed a better diagnostic accuracy (77.4%) with no failure rate.

참고문헌 (19)

  1. Kalagara H, "Point-of-care ultrasound(POCUS)for the cardiothoracic anesthesiologist", J Cardiothorac Vasc Anesth, 36, pp.1132~1147 (2022)
  2. Spencer KT, "Focused cardiac ultrasound : recommendations from the American Society of Echocardiography", J Am Soc Echocardiogr, 26, pp.567~581 (2013)
  3. Südfeld S, "Post-induction hypotension and early intraoperative hypotension associated with general anaesthesia", Br J Anaesth, 119, pp.57~64 (2017)
  4. Jor O, "Hypotension after induction of general anesthesia : occurrence, risk factors, and therapy : a prospective multicentre observational study", J Anesth, 32, pp.673~680 (2018)
  5. Blanco P, "Rationale for using the velocity-time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings", Ultrasound J, 12, pp.21~ (2020)
  6. Desai N, "Assessing dynamic fluid-responsiveness using transthoracic echocardiography in intensive care", BJA Educ, 18, pp.218~226 (2018)
  7. Benes J, "Fluid therapy : double-edged sword during critical care?", Biomed Res Int, 2015, pp.729075~ (2015)
  8. Reich DL, "Predictors of hypotension after induction of general anesthesia", Anesth Analg, 101, pp.622~628 (2005)
  9. Aissaoui Y, "Prediction of post-induction hypotension by point-of-care echocardiography : a prospective observational study", Anaesth Crit Care Pain Med, 41, pp.101090~ (2022)
  10. Wang J, "Effect of VTILVOT variation rate on the assessment of fluid responsiveness in septic shock patients", Medicine (Baltimore), 99, pp.e22702~ (2020)
  11. Szabó M, "Role of inferior vena cava collapsibility index in the prediction of hypotension associated with general anesthesia : an observational study", BMC Anesthesiol, 19, pp.139~ (2019)
  12. Zhang J, "Inferior vena cava ultrasonography before general anesthesia can predict hypotension after induction", Anesthesiology, 124, pp.580~589 (2016)
  13. Airapetian N, "Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?", Crit Care, 19, pp.400~ (2015)
  14. Singh Y, "Role of IVC collapsibility index to predict post spinal hypotension in pregnant women undergoing caesarean section : an observational trial", Saudi J Anaesth, 13, pp.312~317 (2019)
  15. Salama ER, "Pre-operative ultrasonographic evaluation of inferior vena cava collapsibility index and caval aorta index as new predictors for hypotension after induction of spinal anaesthesia : a prospective observational study", Eur J Anaesthesiol, 36, pp.297~302 (2019)
  16. Dinh VA, "Measuring cardiac index with a focused cardiac ultrasound examination in the ED", Am J Emerg Med, 30, pp.1845~1851 (2012)
  17. Hutchings SD, "Trauma resuscitation using echocardiography in a deployed military intensive care unit", J Intensive Care Soc, 14, pp.120~125 (2013)
  18. Bergenzaun L, "Assessing left ventricular systolic function in shock : evaluation of echocardiographic parameters in intensive care", Crit Care, 15, pp.R200~ (2011)
  19. Nega MH, "Incidence and factors associated with post-induction hypotension among adult surgical patients : prospective follow-up study", Int J Surg Open, 49, pp.100565~ (2022)

관련 논문AI추천

Comparison of the Impact of the Anesthesia Induction Using Thiopental and Propofol on Cardiac Function for Non-Cardiac Surgery김수녕, 김태엽, 방승호, 양정현, 양현숙, 오정식, 유가연한국심초음파학회 · Journal of Cardiovascular Imaging2014 · 제22권 제2호Feasibility of a Machine Learning Classifier for Predicting Post-Induction Hypotension in Non-Cardiac Surgery구본욱, 구영현, 구창훈, 김진희, 박인선, 박재현, 오아영연세대학교의과대학 · Yonsei Medical Journal2025 · 제66권 제3호Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor강연승, 구본녀, 김고은, 김선주, 김소연, 윤순영, 정환호연세대학교의과대학 · Yonsei Medical Journal2019 · 제60권 제8호The diagnostic accuracy of ultrasonographic method over manual aspiration technique for gastric reserve volume estimation in critically ill patientsArti Sharma, Jyoti Pathania, Rahul Sharma, Ravi Kant Dogra대한중환자의학회 · Acute and Critical Care2023 · 제38권 제1호The correlation between carotid artery doppler and stroke volume during central blood volume loss and resuscitationAndrew M. Eib, Isabel Kerrebijn, Jenna L. Taylor, Johnson Bruce D., Jon-Émile S. Kenny, Joseph K. Eibl, Kim Chul-Ho, Mai Elfarnawany, Sarah Atwi대한중환자의학회 · Acute and Critical Care2024 · 제39권 제1호Comparing the Rates of Dopamine Hemodynamic Effect Onset after Infusion through Peripheral Veins in Three Regions김덕규, 손지선, 이준례, 임형선, 최원영, 한영진대한중환자의학회 · Acute and Critical Care2017 · 제32권 제1호