승압제를 사용하는 쇼크 환자에서 맥파전달시간을 이용한 비침습적혈압 측정에 대한 비교 연구
A Study on Estimating the Blood Pressure by Using the Pulse Wave Transit Time in Shock Patients Who Received Vasopressor Drugs
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background: Blood pressure is clinically used for monitoring shock patients and as a therapeutic indicator for them. Non-invasive blood pressure measurement has weak points such as the use of a cuff and it is a discontinuous measurement. A method of measuring the blood pressure by using the PWTT (pulse wave transit time) has been studied to make up for those weak points. If blood pressure monitoring can be done by using the difference of the PWTT between different points in the body, then this method will be a quite useful to monitor the BP of seriously ill patients. This study aimed to verify whether or not the PWTT has a significant correlation with the blood pressure of shock patients who received vasopressor infusion and whether this method is clinically applicable. Methods: The study subjects were 20 shock patients who were hospitalized in intensive care units and they had received vasopressor, and we measured the PWTT and we analyzed its correlation with the SBP (systolic blood pressure) and DBP (diastolic blood pressure), as measured by non-invasive monitoring. We then determined the effects of the PWTT on the SBP and DBP. Results: From the results of correlation analysis between the PWTT and the SBP and DBP, the SBP displayed a statistically significant negative correlation with the PWTT of 18 patients, while no significant correlation between the PWTT and DBP was observed. At the same time, from the results of the regression analysis of the blood pressures and the PWTT of each patient, it was found that the PWTT had a negative effect on the SBP of all the patients, except two. Conclusions: The PWTT has a negative correlation with the SBP of the patients who received vasopressor infusion.
Abstract
Background: Blood pressure is clinically used for monitoring shock patients and as a therapeutic indicator for them. Non-invasive blood pressure measurement has weak points such as the use of a cuff and it is a discontinuous measurement. A method of measuring the blood pressure by using the PWTT (pulse wave transit time) has been studied to make up for those weak points. If blood pressure monitoring can be done by using the difference of the PWTT between different points in the body, then this method will be a quite useful to monitor the BP of seriously ill patients. This study aimed to verify whether or not the PWTT has a significant correlation with the blood pressure of shock patients who received vasopressor infusion and whether this method is clinically applicable. Methods: The study subjects were 20 shock patients who were hospitalized in intensive care units and they had received vasopressor, and we measured the PWTT and we analyzed its correlation with the SBP (systolic blood pressure) and DBP (diastolic blood pressure), as measured by non-invasive monitoring. We then determined the effects of the PWTT on the SBP and DBP. Results: From the results of correlation analysis between the PWTT and the SBP and DBP, the SBP displayed a statistically significant negative correlation with the PWTT of 18 patients, while no significant correlation between the PWTT and DBP was observed. At the same time, from the results of the regression analysis of the blood pressures and the PWTT of each patient, it was found that the PWTT had a negative effect on the SBP of all the patients, except two. Conclusions: The PWTT has a negative correlation with the SBP of the patients who received vasopressor infusion.
참고문헌 (23)
- Antonelli M, "Hemodynamic monitoring in shock and implications for management", International Consensus Conference, 통권 : 33, pp.575~590 (2007), Intensive Care Med
- Chen W, "Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration", Med Biol Eng Comput, 38, pp.569~574 (2000)
- Payne RA, "Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure", J Appl Physiol, 100, pp.136~141 (2006)
- Clark JA, "Discrepancies between direct and indirect blood pressure measurements using various recommendations for arm cuff selection", Pediatrics, 110, pp.920~923 (2002)
- Bur A, "Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients", Crit Care Med, 28, pp.371~376 (2000)
- Araghi A, "Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?", Crit Care, 10, pp.R64~ (2006)
- Bull S, "Vascular pressure and critical management", Nurs Clin North Am, 16, pp.225~239 (1981)
- Hong YW, "Arterial pressure monitoring. In: New Critical Medicine", pp.60~61 (1996), Academia Press
- Bur A, "Factors influencing the accuracy of oscillometric blood pressure measurements in critically ill patients", Crit Care Med, 31, pp.793~799 (2003)
- Slogoff S, "On the safety of radial artery cannulation", Anesthesiology, 59, pp.42~47 (1983)
- Cockings JG, "The Australian incident monitoring study. Blood pressure monitoring applications and limitations: an analysis of 2000 incident reports", Anaesth Intensive Care, 21, pp.565~569 (1993)
- Singleton RJ, "The Australian incident monitoring study. Problems associated with vascular access: an analysis of 2000 incident reports", Anaesth Intensive Care, 21, pp.664~669 (1993)
- Paulus DA, "Noninvasive blood pressure measurement", Med Instrum, 15, pp.91~94 (1981)
- Bruner JM, "Automated indirect blood pressure measurement- a point of view", Med Instrum, 18, pp.143~145 (1984)
- Choi BC, "Implement and evaluation of pulse transit time system using photoplethysmograph", 박사, pp.2004
- Geddes LA, "Pulse transit time as an indicator of arterial blood pressure", Psychophysiology, 18, pp.71~74 (1981)
- Lane JD, "Pulse trasit time and blood pressure: an intensive analysis", Psychophysiology, 20, pp.45~49 (1983)
- Hasegawa M, "Increased pulse wave velocity and shortened pulse wave transmission time in hypertension and aging", Cardiology, 88, pp.147~151 (1997)
- Ochiai R, "The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs", J Clin Monit Comput, 15, pp.493~501 (1999)
- Aubert XL, "A model-based study of the influence of vaso-active drugs on pulse delays measured from the electrocardiogram", Computers in Cardiology, 34, pp.383~386 (2007)
- Nicholls WW, "McDonald’s blood flow in arteries: theoretical, experimental and clinical principles. 3rd ed", pp.216~250 (1990), Lea and Febiger
- Pollak MH, "Aortic-radial pulse transit time and ECG Q-wave to radial pulse wave interval as indices of beat-to-beat blood pressure change", Psychophysiology, 20, pp.21~28 (1983)
- Bank AJ, "Direct effects of smooth muscle relaxation and contraction on in vivo human brachial artery elastic properties", Circ Res, 77, pp.1008~1016 (1995)