치과용 임플란트의 안전성과 유효성에 대한 드릴 디자인의 효과
The effect of drill design on stability and efficacy of dental implants
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose : The objective of this research was to investigate an optimization of drill design factors for implant stability and efficacy through comparative evaluation by the cutting time, heat generation and initial stability. Materials and Methods : Three design factors were considered for the purpose of drill design optimization; the number of flute(2 flute, 3 flute), helix angle(15°, 25°) and drill tip shape(straight, 2-phase). Design factors were selected through comparative evaluation by temperature change, cutting time and ISQ value. Results : Heat generation and cutting time are influenced by all design factors(p<0.05). Drill tip shape was the only factors which influenced to the largest initial stability(p<0.05). Conclusion : Drills with 2 flutes, 2-phase formed drill tip, and 25 degrees of helix angle exhibit a better performance than other design.
Abstract
Purpose : The objective of this research was to investigate an optimization of drill design factors for implant stability and efficacy through comparative evaluation by the cutting time, heat generation and initial stability. Materials and Methods : Three design factors were considered for the purpose of drill design optimization; the number of flute(2 flute, 3 flute), helix angle(15°, 25°) and drill tip shape(straight, 2-phase). Design factors were selected through comparative evaluation by temperature change, cutting time and ISQ value. Results : Heat generation and cutting time are influenced by all design factors(p<0.05). Drill tip shape was the only factors which influenced to the largest initial stability(p<0.05). Conclusion : Drills with 2 flutes, 2-phase formed drill tip, and 25 degrees of helix angle exhibit a better performance than other design.
참고문헌 (21)
- Romeo E, "Long-term survival and success of oral implants in the treatment of full and partial arches : a 7-year prospective study with the ITI dental implant system", Int J Oral Maxillofac Implants, 19, pp.247~259 (2004)
- Han DH, "Longitudinal clinical study on the efficacy of osseointegrated dental implants in partially edentulous Korean patients : an 8-years prospective study", J Korean Acad Prosthodont, 39(6), pp.698~708 (2001)
- 서지영, "임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가", 대한치과보철학회지, 44(4), pp.394~404 (2006), 대한치과보철학회
- el Askary AS, "Why do dental implants fail? Part I", Implant Dent, 8, pp.173~185 (1999)
- el Askary AS, "Why do dental implants fail? Part II", Implant Dent, 8, pp.265~277 (1999)
- Kim YG, "Risk Factor in Implant Dentisty", pp.191~218 (2006), Well pub
- Albrektsson T, "Osseointegrated titanium implants. : Requirements for ensuring a long lasting, direct bone anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
- Lundskog, J. Heat, "An experimental investigation of the thermal properties of bone tissue and threshold levels for thermal injury", Scand J Plast Reconstr Surg, 9(suppl 9), pp.1~80 (1972)
- Eriksson RA, "Thermal injury to bone. A vital microscopic description of heat effects", Int J Oral Surg, 1, pp.115~121 (1982)
- Eriksson RA, "Temperature threshold levels for heat-induced bone tissue injury. A vital microscopic study in rabbit", J Prosthet Dent, 50, pp.101~107 (1983)
- Eriksson RA, "The effect of heat on bone regeneration : An experimental study in rabbit using the bone growth chamber", J Oral Maxillofac Surg, 42, pp.705~711 (1984)
- Matthews LS, "Temperatures measured in human cortical bone when drilling", J Bone Joint Surg, 54, pp.297~308 (1972)
- Eriksson RA, "Temperatures during drilling for the placement of implants using the osseointegration technique", J Oral Maxillofac Surg, 44, pp.4~7 (1986)
- Watcher R, "Increase of temperature during osteotomy. In vitro and in vivo investigations", Int J Oral Maxillofac Surg, 20, pp.245~249 (1991)
- Cordioli G, "Heat generation during implant site preparation : An in vitro study", Int J Oral Maxillofac Implants, 12, pp.186~193 (1997)
- ISO, "ISO 14971 : 2007 Medical devices - Application of risk management for medical devices", ISO, ~ (2007)
- 윤지훈, "새로 고안된 임플란트 드릴의 간소화된 드릴링 과정이 온도변화 및 절삭시간에 미치는 영향에 관한 연구", 대한치과재료학회지, 39(1), pp.9~16 (2012), 대한치과재료학회
- Sener BC, "Effects of irrigation temperature on heat control in vitro at different drilling depths", Clinical Oral Implants Research, 20, pp.294~298 (2009)
- Oh HJ, "Effect of implant drill characteristics on heat generation in osteotomy sites : a pilot study", Clinical Oral Implants Research, 22, pp.722~726 (2011)
- Sharawy M, "Heat generation during implant drilling: the significance of motor speed", J Oral Maxillofac Surg, 60(10), pp.1160~1169 (2002)
- Fanuscu MI, "Effect if surgical techniques on primary implant stability and periimplant bone", J Oral Maxillofac Surg, 65, pp.2487~2491 (2007)