본문 바로가기
KERD
논문KCI 등재

니켈티타늄 전동파일 파절의예방 및 처치

Prevention and Solution of the Fracture of Nickel-Titanium Endodontic Instruments

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Nickel-Titanium (NiTi) rotary instruments have brought a big step toward “efficient” practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors. However, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments’ fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments’ fragments would not jeopardize the clinical prognosis of root canal treatment. Nevertheless, it is impossible to be overemphasized that the prevention of file fracture is much easier than the removal of fracture fragment. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

Abstract

Nickel-Titanium (NiTi) rotary instruments have brought a big step toward “efficient” practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors. However, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments’ fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments’ fragments would not jeopardize the clinical prognosis of root canal treatment. Nevertheless, it is impossible to be overemphasized that the prevention of file fracture is much easier than the removal of fracture fragment. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

참고문헌 (15)

  1. Walia HM, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
  2. Thompson SA, "An overview of nickel-titanium alloys used in dentistry", Int Endod J, 33, pp.297~310 (2000)
  3. Glosson CR, "A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments", J Endod, 21, pp.146~151 (1995)
  4. Peters OA, "Current challenges and concepts in the preparation of root canal systems: a review", J Endod, 30, pp.559~567 (2004)
  5. Parashos P, "Rotary NiTi instrument fracture and its consequences", J Endod, 32, pp.1031~1043 (2006)
  6. Tzanetakis GN, "Prevalence and management of instrument fracture in the postgraduate endodontic program at the Dental School of Athens: a fiveyear retrospective clinical study", J Endod, 34, pp.675~678 (2008)
  7. Kim HC, "Cyclic Fatigue and Fracture Characteristics of Ground and Twisted Nickel-Titanium Rotary Files", J Endod, 36, pp.147~152 (2010)
  8. Cheung GS, "Effect of torsional loading of nickel-titanium instruments on cyclic fatigue resistance", J Endod, 39, pp.1593~1597 (2013)
  9. Kim HC, "Comparison of Forces Generated During Root Canal Shaping and Residual Stresses of Three Nickel?Titanium Rotary Files by Using a Three-Dimensional Finite-element Analysis", J Endod, 34, pp.743~747 (2008)
  10. Kim HC, "Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals", Int Endod J, 42, pp.593~602 (2009)
  11. Kim HC, "Potential Relationship between Design of Nickel-Titanium Rotary Instruments and Vertical Root Fracture", J Endod, 36, pp.1195~1199 (2010)
  12. Kim JY, "Effect from cyclic fatigue of nickeltitanium rotary files on torsional resistance", J Endod, 38, pp.527~530 (2012)
  13. Kim TO, "Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis", Int Endod J, 42, pp.14~21 (2009)
  14. Park SY, "Dynamic Torsional Resistance of Nickel-Titanium Rotary Instruments", J Endod, 36, pp.1200~1204 (2010)
  15. Spili P, "The impact of instrument fracture on outcome of endodontic treatment", J Endod, 31, pp.845~850 (2005)

관련 논문AI추천

이 간행물의 다른 논문 (6건)