Rapid Detection of Streptococcus mutans Using an Integrated Microfluidic System with Loop-Mediated Isothermal Amplification
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Streptococcus mutans is the primary causative agent of caries, which is one of the most common human diseases. Thus, rapid and early detection of cariogenic bacteria is critical for its prevention. This study investigated the combination of loop-mediated isothermal amplification (LAMP) and microfluid technology to quantitatively detect S. mutans. A low-cost, rapid microfluidic chip using LAMP technology was developed to amplify and detect bacteria at 2.2–2.2 × 106 colony-forming units (CFU)/ml and its detection limits were compared to those of standard polymerase chain reaction. A visualization system was established to quantitatively determine the experimental results, and a functional relationship between the bacterial concentration and quantitative results was established. The detection limit of S. mutans using this microfluidic chip was 2.2 CFU/ml, which was lower than that of the standard approach. After quantification, the experimental results showed a good linear relationship with the concentration of S. mutans, thereby confirming the effectiveness and accuracy of the custom-made integrated LAMP microfluidic system for the detection of S. mutans. The microfluidic system described herein may represent a promising simple detection method for the specific and rapid testing of individuals at risk of caries.
Abstract
Streptococcus mutans is the primary causative agent of caries, which is one of the most common human diseases. Thus, rapid and early detection of cariogenic bacteria is critical for its prevention. This study investigated the combination of loop-mediated isothermal amplification (LAMP) and microfluid technology to quantitatively detect S. mutans. A low-cost, rapid microfluidic chip using LAMP technology was developed to amplify and detect bacteria at 2.2–2.2 × 106 colony-forming units (CFU)/ml and its detection limits were compared to those of standard polymerase chain reaction. A visualization system was established to quantitatively determine the experimental results, and a functional relationship between the bacterial concentration and quantitative results was established. The detection limit of S. mutans using this microfluidic chip was 2.2 CFU/ml, which was lower than that of the standard approach. After quantification, the experimental results showed a good linear relationship with the concentration of S. mutans, thereby confirming the effectiveness and accuracy of the custom-made integrated LAMP microfluidic system for the detection of S. mutans. The microfluidic system described herein may represent a promising simple detection method for the specific and rapid testing of individuals at risk of caries.
참고문헌 (37)
- Li Y, "Comparison of real-time quantitative PCR with a chairside test for Streptococcus mutans assessment", Chin. J. Dent. Res, 20, pp.199~210 (2017)
- Loesche WJ, "Role of Streptococcus mutans in human dental decay", Microbiol. Rev, 50, pp.353~380 (1986)
- Bai G, "Construction of a fusion anti-caries DNA vaccine in transgenic tomato plants for PAcA gene and cholera toxin B subunit", Biotechnol. Appl. Biochem, 66, pp.924~929 (2019)
- Loesche WJ, "Longitudinal investigation of the role of Streptococcus mutans in human fissure decay", Infect. Immun, 26, pp.498~507 (1979)
- Beighton D, "A simple biochemical scheme for the differentiation of Streptococcus mutans and Streptococcus sobrinus", Caries Res, 25, pp.174~178 (1991)
- Hamada S, "Biology, immunology, and cariogenicity of Streptococcus mutans", Microbiol. Rev, 44, pp.331~384 (1980)
- Smorawinska M, "DNA probes for detection of cariogenic Streptococcus mutans", Oral Microbiol. Immunol, 7, pp.177~181 (1992)
- Zhou P, "A pneumonia outbreak associated with a new coronavirus of probable bat origin", Nature, 579, pp.270~273 (2020)
- Lazcka O, "Pathogen detection: a perspective of traditional methods and biosensors", Biosens. Bioelectron, 22, pp.1205~1217 (2007)
- 김지애, "SF-qPCR: Strand Displacement-Based Fast Quantitative Polymerase Chain Reaction", BioChip Journal, 16(1), pp.41~48 (2022), 한국바이오칩학회[DOI]
- Vincent M, "Helicase-dependent isothermal DNA amplification", EMBO Rep, 5, pp.795~800 (2004)
- Yao C, "Rolling circle amplification (RCA)-based DNA hydrogel", Nat. Protoc, 16, pp.5460~5483 (2021)
- Choi G, "A centrifugal direct recombinase polymerase amplification (direct-RPA) microdevice for multiplex and real-time identification of food poisoning bacteria", Lab Chip, 16, pp.2309~2316 (2016)
- 장민주, "Inhibition of Non-specific Amplification in Loop-Mediated Isothermal Amplification via Tetramethylammonium Chloride", BioChip Journal, 16(3), pp.326~333 (2022), 한국바이오칩학회[DOI]
- Cao G, "Establishment of scalable nanoliter digital LAMP technology for the quantitative detection of multiple myeloproliferative neoplasm molecular markers", Sens. Actuators B, 346, pp.130493~ (2021)
- Notomi T, "Loop-mediated isothermal amplification of DNA", Nucleic Acids Res, 28, pp.E63~ (2000)
- Kim S, "Loop-mediated isothermal amplification-based nucleic acid lateral flow assay for the specific and multiplex detection of genetic markers", Anal. Chim. Acta, 1205, pp.339781~ (2022)
- Hu Yuan-qing, "Rapid and Visual Detection of Vibrio parahaemolyticus in Aquatic Foods Using blaCARB-17 Gene-Based Loop-Mediated Isothermal Amplification with Lateral Flow Dipstick (LAMP-LFD)", Journal of Microbiology and Biotechnology, 31(12), pp.1672~1683 (2021), 한국미생물·생명공학회[DOI]
- Nagamine K, "Isolation of single-stranded DNA from loop-mediated isothermal amplification products", Biochem. Biophys. Res. Commun, 290, pp.1195~1198 (2002)
- Nagamine K, "Accelerated reaction by loop-mediated isothermal amplification using loop primers", Mol. Cell. Probes, 16, pp.223~229 (2002)
- Park S, "Advances in microfluidic PCR for point-of-care infectious disease diagnostics", Biotechnol. Adv, 29, pp.830~839 (2011)
- Drese KS, "Lab on a chip", Internist (Berl.). German, 60, pp.339~344 (2019)
- Huang G, "A rapid, low-cost, and microfluidic chipbased system for parallel identification of multiple pathogens related to clinical pneumonia", Sci. Rep, 7, pp.6441~ (2017)
- Terry SC, "A gas chromatographic air analyzer fabricated on a silicon wafer", IEEE Trans. Electron. Devices, 26, pp.1880~1886 (1979)
- Dittrich PS, "Micro total analysis systems. Latest advancements and trends", Anal. Chem, 78, pp.3887~3908 (2006)
- Fang X, "Loop-mediated isothermal amplification integrated on microfluidic chips for point-of-care quantitative detection of pathogens", Anal. Chem, 82, pp.3002~3006 (2010)
- Van Nguyen H, "Point-of-care genetic analysis for multiplex pathogenic bacteria on a fully integrated centrifugal microdevice with a large-volume sample", Biosens. Bioelectron, 136, pp.132~139 (2019)
- Herr AE, "Integrated microfluidic platform for oral diagnostics", Ann. N. Y. Acad. Sci, 1098, pp.362~374 (2007)
- Li Z, "All-in-one microfluidic device for on-site diagnosis of pathogens based on an integrated continuous flow PCR and electrophoresis biochip", Lab. Chip, 19, pp.2663~2668 (2019)
- Hunt RWG, "Measuring Colour" (2011), John Wiley & Sons, Ltd
- Joiner A, "Tooth colour: a review of the literature", J. Dent, 32, pp.3~12 (2004)
- O'Brien WJ, "Color distribution of three regions of extracted human teeth", Dent. Mater, 13, pp.179~185 (1997)
- Fischbach J, "Shining a light on LAMP assays--a comparison of LAMP visualization methods including the novel use of berberine", Biotechniques, 58, pp.189~194 (2015)
- He Y, "Rapid and highly sensitive one-tube colorimetric RT-LAMP assay for visual detection of SARS-CoV-2RNA", Biosens. Bioelectron, 187, pp.113330~ (2021)
- Bau HH, "Is instrument-free molecular detection possible?", Expert Rev. Mol. Diagn, 17, pp.949~951 (2017)
- Nam D, "Low-temperature loop-mediated isothermal amplification operating at physiological temperature", Biosensors (Basel), 13(3), pp.367~ (2023)[DOI]
- Liqun Xia, "Development of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Nocardia salmonicida, the Causative Agent of Nocardiosis in Fish", Journal of Microbiology and Biotechnology, 25(3), pp.321~327 (2015), 한국미생물·생명공학회[DOI]
