Effects of small tidal volume and positive end-expiratory pressure on oxygenation in pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: The purpose of this study was to investigate whether tidal volume (TV) of 8 mL/kg without positive end-expiratory pressure (PEEP) and TV of 6 mL/kg with or without PEEP in pressure-controlled ventilation-volume guaranteed (PCV-VG) mode can maintain arterial oxygenation and decrease inspiratory airway pressure effectively during one-lung ventilation (OLV). Methods: The study enrolled 27 patients undergoing thoracic surgery. All patients were ventilated with PCVVG mode. During OLV, patients were initially ventilated with TV 8 mL/kg (group TV8) without PEEP. Ventilation was subsequently changed to TV 6 mL/kg with PEEP (5 cmH2O; group TV6+PEEP) or without (group TV6) in random sequence. Peak inspiratory pressure (Ppeak), mean airway pressure (Pmean), and arterial blood gas analysis were measured 30 min after changing ventilator settings. Ventilation was then changed once more to add or eliminate PEEP (5 cmH2O), while maintaining TV 6 mL/kg. Thirty min after changing ventilator settings, the same parameters were measured once more. Results: The Ppeak was significantly lower in group TV6 (19.3±3.3 cmH2O) than in group TV8 (21.8±3.1 cmH2O) and group TV6+PEEP (20.1±3.4 cmH2O). PaO2 was significantly higher in group TV8 (242.5±111.4 mmHg) than in group TV6 (202.1±101.3 mmHg) (p=0.044). There was no significant difference in PaO2 between group TV8 and group TV6+PEEP (226.8±121.1 mmHg). However, three patients in group TV6 were dropped from the study because PaO2 was lower than 80 mmHg after ventilation. Conclusion: It is postulated that TV 8 mL/kg without PEEP or TV 6 mL/kg with 5 cmH2O PEEP in PCV-VG mode during OLV can safely maintain adequate oxygenation.
Abstract
Background: The purpose of this study was to investigate whether tidal volume (TV) of 8 mL/kg without positive end-expiratory pressure (PEEP) and TV of 6 mL/kg with or without PEEP in pressure-controlled ventilation-volume guaranteed (PCV-VG) mode can maintain arterial oxygenation and decrease inspiratory airway pressure effectively during one-lung ventilation (OLV). Methods: The study enrolled 27 patients undergoing thoracic surgery. All patients were ventilated with PCVVG mode. During OLV, patients were initially ventilated with TV 8 mL/kg (group TV8) without PEEP. Ventilation was subsequently changed to TV 6 mL/kg with PEEP (5 cmH2O; group TV6+PEEP) or without (group TV6) in random sequence. Peak inspiratory pressure (Ppeak), mean airway pressure (Pmean), and arterial blood gas analysis were measured 30 min after changing ventilator settings. Ventilation was then changed once more to add or eliminate PEEP (5 cmH2O), while maintaining TV 6 mL/kg. Thirty min after changing ventilator settings, the same parameters were measured once more. Results: The Ppeak was significantly lower in group TV6 (19.3±3.3 cmH2O) than in group TV8 (21.8±3.1 cmH2O) and group TV6+PEEP (20.1±3.4 cmH2O). PaO2 was significantly higher in group TV8 (242.5±111.4 mmHg) than in group TV6 (202.1±101.3 mmHg) (p=0.044). There was no significant difference in PaO2 between group TV8 and group TV6+PEEP (226.8±121.1 mmHg). However, three patients in group TV6 were dropped from the study because PaO2 was lower than 80 mmHg after ventilation. Conclusion: It is postulated that TV 8 mL/kg without PEEP or TV 6 mL/kg with 5 cmH2O PEEP in PCV-VG mode during OLV can safely maintain adequate oxygenation.
참고문헌 (14)
- 윤두균, "Is small tidal volume with low positive end expiratory pressure during one-lung ventilation an effective ventilation method for endoscopic thoracic surgery?", Korean Journal of Anesthesiology, 67(5), pp.329~333 (2014), 대한마취통증의학회
- 김희주, "Protective strategies for one-lung ventilation", Korean Journal of Anesthesiology, 67(4), pp.233~234 (2014), 대한마취통증의학회
- 정종달, "Effects of a preemptive alveolar recruitment strategy on arterial oxygenation during one-lung ventilation with different tidal volumes in patients with normal pulmonary function test", Korean Journal of Anesthesiology, 67(2), pp.96~102 (2014), 대한마취통증의학회
- 이원진, "Airway dimensions and margin of safety with the left-sided double-lumen tube in patients of a short stature", Anesthesia and Pain Medicine, 10(2), pp.110~117 (2015), 대한마취통증의학회
- Tuğrul M, "Comparison of volume controlled with pressure controlled ventilation during one-lung anaesthesia", Br J Anaesth, 79, pp.306~310 (1997)
- Unzueta MC, "Pressure-controlled versus volume-controlled ventilation during one-lung ventilation for thoracic surgery", Anesth Analg, 104, pp.1029~1033 (2007)
- Boules NS, "Efficiency of the newly introduced ventilatory mode “pressure controlled ventilation-volume guaranteed”in thoracic surgery with one lung ventilation", Egypt J Anaesth, 27, pp.113~119 (2011)
- Pu J, "Applications of pressure control ventilation volume guaranteed during one-lung ventilation in thoracic surgery", Int J Clin Exp Med, 7, pp.1094~1098 (2014)
- Végh T, "Effects of different tidal volumes for one-lung ventilation on oxygenation with open chest condition and surgical manipulation: a randomised cross-over trial", Minerva Anestesiol, 79, pp.24~32 (2013)
- Keszler M, "Volume-targeted ventilation", Early Hum Dev, 82, pp.811~818 (2006)
- 송석영, "Volume-controlled versus pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation", Korean Journal of Anesthesiology, 67(4), pp.258~263 (2014), 대한마취통증의학회
- Gal TJ, "Con: low tidal volumes are indicated during one-lung ventilation", Anesth Analg, 103, pp.271~273 (2006)
- Fernández-Pérez ER, "Intraoperative ventilator settings and acute lung injury after elective surgery: a nested case control study", Thorax, 64, pp.121~127 (2009)
- Kim SH, "Effects of tidal volume and PEEP on arterial blood gases and pulmonary mechanics during onelung ventilation", J Anesth, 26, pp.568~573 (2012)
