Evaluation of Respiratory Dynamics in an Asymmetric Lung Compliance Model

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Background: Unilateral lung hyperinflation develops in lungs with asymmetric compliance, which can lead to vital instability. The aim of this study was to investigate the respiratory dynamics and the effect of airway diameter on the distribution of tidal volume during mechanical ventilation in a lung model with asymmetric compliance. Methods: Three groups of lung models were designed to simulate lungs with a symmetric and asymmetric compliance. The lung model was composed of two test lungs, lung1 and lung2. The static compliance of lung1 in C15, C60, and C120 groups was manipulated to be 15, 60, and 120 ml/cmH2O, respectively. Meanwhile, the static compliance of lung2 was fixed at 60 ml/cmH2O. Respiratory variables were measured above (proximal measurement) and below (distal measurement) the model trachea. The lung model was mechanically ventilated, and the airway internal diameter (ID) was changed from 3 to 8 mm in 1-mm increments. Results: The mean ± standard deviation ratio of volumes distributed to each lung (VL1/VL2) in airway ID 3, 4, 5, 6, 7, and 8 were in order, 0.10 ± 0.05, 0.11 ± 0.03, 0.12 ± 0.02, 0.12 ± 0.02, 0.12 ± 0.02, and 0.12 ± 0.02 in the C15 group; 1.05 ± 0.16, 1.01 ± 0.09, 1.00 ± 0.07, 0.97 ± 0.09, 0.96 ± 0.06, and 0.97 ± 0.08 in the C60 group; and 1.46 ± 0.18, 3.06 ± 0.41, 3.72 ± 0.37, 3.78 ± 0.47, 3.77 ± 0.45, and 3.78 ± 0.60 in the C120 group. The positive end-expiratory pressure (PEEP) of lung1 was significantly increased at airway ID 3 mm (1.65 cmH2O) in the C15 group; at ID 3, 4, and 5 mm (2.21, 1.06, and 0.95 cmH2O) in the C60 group; and ID 3, 4, and 5 mm (2.92, 1.84, and 1.41 cmH2O) in the C120 group, compared to ID 8 mm (P < 0.05). Conclusions: In the C15 and C120 groups, the tidal volume was unevenly distributed to both lungs in a positive relationship with lung compliance. In the C120 group, the uneven distribution of tidal volume was improved when the airway ID was equal to or less than 4 mm, but a significant increase of PEEP was observed.

Abstract

Background: Unilateral lung hyperinflation develops in lungs with asymmetric compliance, which can lead to vital instability. The aim of this study was to investigate the respiratory dynamics and the effect of airway diameter on the distribution of tidal volume during mechanical ventilation in a lung model with asymmetric compliance. Methods: Three groups of lung models were designed to simulate lungs with a symmetric and asymmetric compliance. The lung model was composed of two test lungs, lung1 and lung2. The static compliance of lung1 in C15, C60, and C120 groups was manipulated to be 15, 60, and 120 ml/cmH2O, respectively. Meanwhile, the static compliance of lung2 was fixed at 60 ml/cmH2O. Respiratory variables were measured above (proximal measurement) and below (distal measurement) the model trachea. The lung model was mechanically ventilated, and the airway internal diameter (ID) was changed from 3 to 8 mm in 1-mm increments. Results: The mean ± standard deviation ratio of volumes distributed to each lung (VL1/VL2) in airway ID 3, 4, 5, 6, 7, and 8 were in order, 0.10 ± 0.05, 0.11 ± 0.03, 0.12 ± 0.02, 0.12 ± 0.02, 0.12 ± 0.02, and 0.12 ± 0.02 in the C15 group; 1.05 ± 0.16, 1.01 ± 0.09, 1.00 ± 0.07, 0.97 ± 0.09, 0.96 ± 0.06, and 0.97 ± 0.08 in the C60 group; and 1.46 ± 0.18, 3.06 ± 0.41, 3.72 ± 0.37, 3.78 ± 0.47, 3.77 ± 0.45, and 3.78 ± 0.60 in the C120 group. The positive end-expiratory pressure (PEEP) of lung1 was significantly increased at airway ID 3 mm (1.65 cmH2O) in the C15 group; at ID 3, 4, and 5 mm (2.21, 1.06, and 0.95 cmH2O) in the C60 group; and ID 3, 4, and 5 mm (2.92, 1.84, and 1.41 cmH2O) in the C120 group, compared to ID 8 mm (P < 0.05). Conclusions: In the C15 and C120 groups, the tidal volume was unevenly distributed to both lungs in a positive relationship with lung compliance. In the C120 group, the uneven distribution of tidal volume was improved when the airway ID was equal to or less than 4 mm, but a significant increase of PEEP was observed.

참고문헌 (15)

  1. Fitting JW., "Respiratory muscles in chronic obstructive pulmonary disease", Swiss Med Wkly, 131, pp.483~486 (2001)
  2. Ahmed SM, "Mechanical ventilation in patients with chronic obstructive pulmonary disease and bronchial asthma", Indian J Anaesth, 59, pp.589~598 (2015)
  3. Caramez MP, "Paradoxical responses to positive end-expiratory pressure in patients with airway obstruction during controlled ventilation", Crit Care Med, 33, pp.1519~1528 (2005)
  4. Lumb AB., "Nunn’s applied respiratory physiology" (2010), Churchill Livingstone
  5. Venuta F, "Complications in the native lung after single lung transplantation", Eur J Cardiothorac Surg, 16, pp.54~58 (1999)
  6. Kollef MH, "Intrinsic PEEP and unilateral lung hyperinflation: pathophysiology and clinical significance", Chest, 102, pp.1220~1224 (1992)
  7. Eveloff SE, "Unilateral lung hyperinflation and herniation as a manifestation of intrinsic PEEP", Chest, 98, pp.228~229 (1990)
  8. 박상현, "변경할 수 있는 유순도 모델에서 호흡역학에 대한 상기도 폐쇄의 효과", Anesthesia and Pain Medicine, 6(3), pp.244~248 (2011), 대한마취통증의학회
  9. Al-Rawas N, "Expiratory time constant for determinations of plateau pressure, respiratory system compliance, and total resistance", Crit Care, 17, pp.R23~ (2013)
  10. Melo e Silva CA, "A simple model illustrating the respiratory system’s time constant concept", Adv Physiol Educ, 30, pp.129~130 (2006)
  11. Hess DR., "Respiratory mechanics in mechanically ventilated patients", Respir Care, 59, pp.1773~1794 (2014)
  12. Schumaker GL, "Managing acute respiratory failure during exacerbation of chronic obstructive pulmonary disease", Respir Care, 49, pp.766~782 (2004)
  13. O’Donnell DE, "Dynamic hyperinflation and exercise intolerance in chronic obstructive pulmonary disease", Am J Respir Crit Care Med, 164, pp.770~777 (2001)
  14. Puente-Maestu L, "Dyspnea, ventilatory pattern, and changes in dynamic hyperinflation related to the intensity of constant work rate exercise in COPD", Chest, 128, pp.651~656 (2005)
  15. Anglès R, "Lung transplantation for emphysema. Lung hyperinflation: incidence and outcome", Transpl Int, 17, pp.810~814 (2005)

관련 논문AI추천

이 간행물의 다른 논문 (16건)