Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.
Abstract
Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.
참고문헌 (27)
- Qian K, "Marginal adaptation of different hybrid ceramic inlays after thermal cycling", Adv Appl Ceram, 119, pp.1~7 (2020)
- Esquivel-Upshaw JF, "Fracture resistance of all-ceramic and metal-ceramic inlays", Int J Prosthodont, 14, pp.109~114 (2001)
- Nakamura T, "Stress analysis of metal-free polymer crowns using the three-dimensional finite element method", Int J Prosthodont, 14, pp.401~405 (2001)
- Homsy FR, "Comparison of fit accuracy of pressed lithium disilicate inlays fabricated from wax or resin patterns with conventional and CAD-CAM technologies", J Prosthet Dent, 120, pp.530~536 (2018)
- Homsy FR, "Marginal and internal fit of pressed lithium disilicate inlays fabricated with milling, 3D printing, and conventional technologies", J Prosthet Dent, 119, pp.783~790 (2018)
- Lauvahutanon S, "Mechanical properties of composite resin blocks for CAD", CAM, 2014, pp.33, 705~710
- Paolone G, "Color stability of polymer-based composite CAD", CAM blocks: a systematic review, 2023, pp.15, 464~
- Sidhom M, "Effect of different CAD", CAM milling and 3D printing digital fabrication techniques on the accuracy of PMMA working models and vertical marginal fit of PMMA provisional dental prosthesis: an in vitro study, 2022, pp.14, 1285~
- Jeong YG, "Accuracy evaluation of dental models manufactured by CAD", CAM milling method and 3D printing method, 2018, pp.10, 245~251
- Sorensen JA, "A standardized method for determination of crown margin fidelity", J Prosthet Dent, 64, pp.18~24 (1990)
- Park JY, "Evaluation of the marginal and internal gaps of three different dental prostheses : comparison of the silicone replica technique and three-dimensional superimposition analysis", J Adv Prosthodont, 9, pp.159~169 (2017)
- Nawafleh NA, "Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs : a literature review", J Prosthodont, 22, pp.419~428 (2013)
- Kim KB, "Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology : two-and three-dimensional replica techniques", J Adv Prosthodont, 5, pp.179~186 (2013)
- Karakaya S, "Evaluation of internal adaptation in ceramic and composite resin inlays by silicon replica technique", J Oral Rehabil, 32, pp.448~453 (2005)
- Shin Y, "Evaluation of the marginal and internal discrepancies of CAD-CAM endocrowns with different cavity depths : an in vitro study", J Prosthet Dent, 117, pp.109~115 (2017)
- Boitelle P, "A systematic review of CAD", CAM fit restoration evaluations, 2014, pp.41, 853~874
- Stappert CF, "Effect of mouth-motion fatigue and thermal cycling on the marginal accuracy of partial coverage restorations made of various dental materials", Dent Mater, 24, pp.1248~1257 (2008)
- Park SH, "Marginal and internal fit of nano-composite CAD", CAM restorations, 2016, pp.41, 37~43
- Goujat A, "Marginal and internal fit of CAD-CAM inlay", onlay restorations : a systematic review of in vitro studies, 2019, pp.121, 590~597
- Rippe MP, "Different methods for inlay production: effect on internal and marginal adaptation, adjustment time, and contact point", Oper Dent, 42, pp.436~444 (2017)
- Seo D, "The effect of preparation designs on the marginal and internal gaps in Cerec3 partial ceramic crowns", J Dent, 37, pp.374~382 (2009)
- Tsitrou EA, "Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD", CAM, 2007, pp.35, 68~73
- DeLong R, "Factors influencing optical 3D scanning of vinyl polysiloxane impression materials", J Prosthodont, 10, pp.78~85 (2001)
- El Zohairy AA, "Microtensile bond strength testing of luting cements to prefabricated CAD", CAM ceramic and composite blocks, 2003, pp.19, 575~583
- Zarrati S, "Marginal adaptation of indirect composite, glass-ceramic inlays and direct composite: an in vitro evaluation", J Dent(Tehran), 7, pp.77~83 (2010)
- Sener-Yamaner ID, "Effect of material and fabrication technique on marginal fit and fracture resistance of adhesively luted inlays made of CAD", CAM ceramics and hybrid materials, 2017, pp.31, 55~70
- Groten M, "Determination of the minimum number of marginal gap measurements required for practical in-vitro testing", J Prosthet Dent, 83, pp.40~49 (2000)