인공와우 조율에서 주파수별 전기자극수준의 변화양상
A Longitudinal Study of Frequency Specific Electrical Stimulation Levels in Cochlear Implant Users
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background and Objectives The purpose of the study was to evaluate the changes in electrical stimulation levels, i.e. threshold (T) levels, comfortable (C) levels, dynamic range (DR), and electrode impedance values (EIVs) during the first year in cochlear implant users. Subjects and Method The maps of 49 cochlear implant users (at least 1 year mapping), using the Nucleus device, were examined at the time of initial connection, and at 6 and 12 months post-initial stimulation. T levels, C levels, DR and EIVs were analyzed according to three frequency levels. Results During the first 6 months of implant use, C levels and DR increased significantly whereas T levels were stable. EIVs of current carrying electrodes decreased significantly from the connection to the 12-month visit. The changes of electrical stimulation levels did not differ among three frequency levels during the entire follow-up. Conclusion During the first 6 months of implant use, C levels and DR increased significantly. Thus, an appropriate mapping in the first 6 month is critical to setup hearing capacity in implant users. The mapping should be performed under the best communication environment between the audiologist and the patient, and it makes correct setting of T levels from the initial connection period.
Abstract
Background and Objectives The purpose of the study was to evaluate the changes in electrical stimulation levels, i.e. threshold (T) levels, comfortable (C) levels, dynamic range (DR), and electrode impedance values (EIVs) during the first year in cochlear implant users. Subjects and Method The maps of 49 cochlear implant users (at least 1 year mapping), using the Nucleus device, were examined at the time of initial connection, and at 6 and 12 months post-initial stimulation. T levels, C levels, DR and EIVs were analyzed according to three frequency levels. Results During the first 6 months of implant use, C levels and DR increased significantly whereas T levels were stable. EIVs of current carrying electrodes decreased significantly from the connection to the 12-month visit. The changes of electrical stimulation levels did not differ among three frequency levels during the entire follow-up. Conclusion During the first 6 months of implant use, C levels and DR increased significantly. Thus, an appropriate mapping in the first 6 month is critical to setup hearing capacity in implant users. The mapping should be performed under the best communication environment between the audiologist and the patient, and it makes correct setting of T levels from the initial connection period.
참고문헌 (15)
- Mens LH, "Electrical impedance of the cochlear implant lubricants hyaluronic acid, oxycellulose, and glycerin", Ann Otol Rhinol Laryngol, 106(8), pp.653~656 (1997)
- Huang CQ, "Effects of steroids and lubricants on electrical impedance and tissue response following cochlear implantation", Cochlear Implants Int, 8(3), pp.123~147 (2007)
- 오수희, "인공와우에서 신경반응 원격 측정법 역치와 행동반응 결과의 비교", 대한이비인후과학회지 두경부외과학, 49(3), pp.274~278 (2006), 대한이비인후과학회
- Henkin Y, "A longitudinal study of electrical stimulation levels and electrode impedance in children using the Clarion cochlear implant", Acta Otolaryngol, 126(6), pp.581~586 (2006)
- Henkin Y, "Changes over time in the psycho-electric parameters in children with cochlear implants", Int J Audiol, 42(5), pp.274~278 (2003)
- Shapiro W, "Changes in electrical thresholds over time in young children implanted with the Nucleus cochlear prosthesis", Ann Otol Rhinol Laryngol Suppl, 166, pp.177~178 (1995)
- Hughes ML, "A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users", Ear Hear, 22(6), pp.471~486 (2001)
- Henkin Y, "Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implant", Int J Pediatr Otorhinolaryngol, 67(8), pp.873~880 (2003)
- Wolfe J, "Programming Cochlear Implants" (2010), Plural Pub.
- Kubo T, "Auditory plasticity in cochlear implant patients", Acta Otolaryngol, 116(2), pp.224~227 (1996)
- Butts SL, "Changes in stimulation levels over time in nucleus 22 cochlear implant users", Ann Otol Rhinol Laryngol Suppl, 185, pp.53~56 (2000)
- Jose Luis Vargas, "Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients", Clinical and Experimental Otorhinolaryngology, 5(4), pp.194~200 (2012), 대한이비인후과학회
- 오수희, "인공와우 이식아동의 전기자극 수준 변화에 대한 장기 추적 연구", 대한이비인후과학회지 두경부외과학, 51(3), pp.217~220 (2008), 대한이비인후과학회
- Kim SJ, "Evaluation of speech perception abilities in children with cochlear implants", Korean J Otolaryngol- Head Neck Surg, 41(11), pp.1391~1399 (1998)
- 서명환, "Long Term Outcomes of Early Cochlear Implantation in Korea", Clinical and Experimental Otorhinolaryngology, 2(3), pp.120~125 (2009), 대한이비인후과학회
