imObjectives. The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. Methods. Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada,Spain. Hearing loss etiology and progression characteristics varied across subjects. Results. The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. Conclusion. We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor.

Abstract

imObjectives. The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. Methods. Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada,Spain. Hearing loss etiology and progression characteristics varied across subjects. Results. The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. Conclusion. We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor.

참고문헌 (20)

  1. Wilson BS, "Better speech recognition with cochlear implants", Nature, 352(6332), pp.236~238 (1991)
  2. Loizou PC, "Mimicking the human ear", IEEE Signal Process Mag, 15(5), pp.101~130 (1998)
  3. Dawson PW, "The effect of loudness imbalance between electrodes in cochlear implant users", Ear Hear, 18(2), pp.156~165 (1997)
  4. Battmer RD, "Fitting in the real world: all the practical questions and problems", The 5th European Symposium on Paediatric Cochlear Implantation (2000)
  5. Hodges AV, "Electrical middle ear muscle reflex: use in cochlear implant programming", Otolaryngol Head Neck Surg, 117(3), pp.255~261 (1997)
  6. Brown CJ, "Relationship between EABR thresholds and levels used to program the CLARION speech processor", Ann Otol Rhinol Laryngol Suppl, 177, pp.50~57 (1999)
  7. Stephan K, "Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants", Audiology, 39(1), pp.13~18 (2000)
  8. Han DM, "Comparisons between neural response imaging thresholds, electrically evoked auditory reflex thresholds and most comfortable loudness levels in CII bionic ear users with HiResolution sound processing strategies", Acta Otolaryngol, 125(7), pp.732~735 (2005)
  9. King JE, "Use of neural response telemetry measures to objectively set the comfort levels in the Nucleus 24 cochlear implant", J Am Acad Audiol, 17(6), pp.413~431 (2006)
  10. Holstad BA, "Relation of electrically evoked compound action potential thresholds to behavioral T- and C-levels in children with cochlear implants", Ear Hear, 30(1), pp.115~127 (2009)
  11. Alvarez I, "Using evoked compound action potentials to assess activation of electrodes and predict C-levels in the Tempo+ cochlear implant speech processor", Ear Hear, 31(1), pp.134~145 (2010)
  12. Shallop JK, "Relationships among comfort levels determined by cochlear implant patient’s self-programming, audiologist’s programming, and electrical stapedius reflex thresholds", Ann Otol Rhinol Laryngol Suppl, 166, pp.175~176 (1995)
  13. Madell J, "Using speech perception errors to modify programming", The 8th Symposium on Cochlear Implants in Children (2001)
  14. Sainz M, "Perceptual thresholds of the electrical impulses in cochlear implanted patients", The 8th Symposium on Cochlear Implants in Children (2001)
  15. Schmidt M, "Long-term stability of fitting parameters with the COMBI 40", Am J Otol, 18(6), pp.109~110 (1997)
  16. Hughes ML, "A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users", Ear Hear, 22(6), pp.471~486 (2001)
  17. Henkin Y, "Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implant", Int J Pediatr Otorhinolaryngol, 67(8), pp.873~880 (2003)
  18. Brown CJ, "The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: data from adults", Ear Hear, 21(2), pp.151~163 (2000)
  19. Franck KH, "Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of Cochlear Corporation’s CI24M device", Ear Hear, 22(4), pp.289~299 (2001)
  20. Welch BL., "The significance of the difference between two means when the population variances are unequal", Biometrika, 29(3), pp.350~362 (1938)

관련 논문AI추천

인공와우 조율에서 주파수별 전기자극수준의 변화양상박상헌, 박의현, 임기정, 장지원, 정광진, 탁평곤대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2013 · 제56권 제4호Dynamic Range and Neural Response Threshold in Cochlear Implant Mapping Can Be Useful in Predicting Prognosis Related to Postoperative Speech PerceptionChoi Soo Jeong, Im Gi Jung, Jung Hak Hyun, Kwak Sooun, Lee Juhyun, Park Bongil, Park Euyhyun, Thak Pyung Kon대한청각학회 · Journal of Audiology & Otology2023 · 제27권 제4호Effects of Electrical Stimulation Rate on Speech Recognition in Cochlear Implant Users김형종, 이효정, Eunoak Kim, Sung Hye Park대한청각학회 · Journal of Audiology & Otology2012 · 제16권 제1호Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types강시형, 김은연, 문일준, 백은주, 설혜윤, 이지영, 홍성화대한청각학회 · Journal of Audiology & Otology2019 · 제23권 제3호Perceptual Loudness Growth in Cochlear Implant Users이성민, 이수정한국청각언어재활학회 · Audiology and Speech Research2022 · 제18권 제2호Longitudinal music perception performance of postlingual deaf adults with cochlear implants using acoustic and/or electrical stimulation김성경, 김하니, 신수진, 신유리, 이은영, 장선아, 전영명, Yeabitna Lee한국음성학회 · 말소리와 음성과학2021 · 제13권 제2호

이 간행물의 다른 논문 (11건)