Purpose: The purpose of this study was to assess the changes in gain, aided threshold, word recognition in noise, and sound quality of hearing aids according to the first wearing period of sensorineural hearing loss (SNHL) to determine the rehabilitation goal and effective adjustments of the electroacoustic parameters. Methods: The subjects of this study were 17 SNHL (26 ears) who had no experience in wearing hearing aids, with an average age of 67.5 years, an average pure-tone average of 50.5 dB HL, an average WRS of 68.9%, and a K-IOI-HA (Korean version of International Outcome Inventory for Hearing Aids) score of 25 or higher. The procedure for gain adjustment of the hearing aid was through NAL-NL2 (National Acoustic Laboratories, non-linear version 2) at first adjustment and subjective responses of the subject afterwards. Real-ear insertion gain, aided threshold, WRS in noise, and sound quality evaluation were conducted at week 0 (initial fit), week 2, and week 6 (or final visit). Results: The study showed a higher gain in 55 dB sound pressure level at most frequencies and improved aided thresholds at 1,000 Hz and 2,000 Hz as the wearing period increased. WRS also increased in 10 dB and 5 dB signal-to-noise ratios, and the sharpness, occlusion, and loudness of noise were shown to improve despite the increased gain. Conclusion: Despite the limitation of gain change with the wearing period, the results of this study expect to aid in setting rehabilitation goals according to the wearing period and adjusting electroacoustic parameters.

Abstract

Purpose: The purpose of this study was to assess the changes in gain, aided threshold, word recognition in noise, and sound quality of hearing aids according to the first wearing period of sensorineural hearing loss (SNHL) to determine the rehabilitation goal and effective adjustments of the electroacoustic parameters. Methods: The subjects of this study were 17 SNHL (26 ears) who had no experience in wearing hearing aids, with an average age of 67.5 years, an average pure-tone average of 50.5 dB HL, an average WRS of 68.9%, and a K-IOI-HA (Korean version of International Outcome Inventory for Hearing Aids) score of 25 or higher. The procedure for gain adjustment of the hearing aid was through NAL-NL2 (National Acoustic Laboratories, non-linear version 2) at first adjustment and subjective responses of the subject afterwards. Real-ear insertion gain, aided threshold, WRS in noise, and sound quality evaluation were conducted at week 0 (initial fit), week 2, and week 6 (or final visit). Results: The study showed a higher gain in 55 dB sound pressure level at most frequencies and improved aided thresholds at 1,000 Hz and 2,000 Hz as the wearing period increased. WRS also increased in 10 dB and 5 dB signal-to-noise ratios, and the sharpness, occlusion, and loudness of noise were shown to improve despite the increased gain. Conclusion: Despite the limitation of gain change with the wearing period, the results of this study expect to aid in setting rehabilitation goals according to the wearing period and adjusting electroacoustic parameters.

참고문헌 (26)

  1. Andersson, G., "Predictors of daily assessed hearing aid use and hearing capability using visual analogue scales", British Journal of Audiology, 30(1), pp.27~35 (1996)
  2. 방어지니, "A Study on the Preferred Real-Ear Insertion Gain of Multi-Channel Hearing Aid for the Korean with Sensorineural Hearing Loss", Audiology and Speech Research, 16(2), pp.85~94 (2020), 한국청각언어재활학회
  3. Byrne, D., "Evaluation of the National Acoustic Laboratories' new hearing aid selection procedure", Journal of Speech and Hearing Research, 31(2), pp.178~186 (1988)
  4. 추호석, "한국어판 International Outcome Inventory for Hearing Aids(IOI-HA)의 표준화: 타당도 및 신뢰도 검증", 대한이비인후-두경부외과학회지, 55(1), pp.20~25 (2012), 대한이비인후과학회
  5. Convery, E., "Factors associated with successful setup of a self-fitting hearing aid and the need for personalized support", Ear and Hearing, 40(4), pp.794~804 (2019)
  6. Cox, R. M., "Benefit acclimatization in elderly hearing aid users", Journal of the American Academy of Audiology, 7(6), pp.428~441 (1996)
  7. Dawes, P., "Acclimatization to hearing aids", Ear and Hearing, 35(2), pp.203~212 (2014)
  8. Erler, S. F., "Hearing loss-and hearing aidrelated stigma : Perceptions of women with age-normal hearing", American Journal of Audiology, 11(2), pp.83~91 (2002)
  9. Foster, J. R., "The four alternative auditory feature test(FAAF)--linguistic and psychometric properties of the material with normative data in noise", British Journal of Audiology, 21(3), pp.165~174 (1987)
  10. Hickson, L., "Factors associated with hearing aid fitting outcomes on the IOI-HA", International Journal of Audiology, 49(8), pp.586~595 (2010)
  11. International Organization for Standardization(ISO), "ISO 21388:2020. Acoustics-Hearing Aid Fitting Management (HAFM)", ISO, ~ (2020)
  12. Keidser, G., "Variation in preferred gain with experience for hearing-aid users", International Journal of Audiology, 47(10), pp.621~635 (2008)
  13. Kiessling, J., "Adaptive fitting of hearing instruments by category loudness scaling(ScalAdapt)", Scandinavian Audiology, 25(3), pp.153~160 (1996)
  14. 김대영, "Development of Korean Version of Profile of Hearing Aid Benefit-Quick Version", Audiology and Speech Research, 16(3), pp.196~205 (2020), 한국청각언어재활학회
  15. 고요셉, "보청기 착용 효과 측정을 위한 음장어음인지평가의 임상적 중요성", 대한이비인후-두경부외과학회지, 64(5), pp.310~320 (2021), 대한이비인후과학회[DOI]
  16. Korean Agency for Technology and Standards(KATS), "KS I 0562:2018. Acoustics-Hearing Aid Fitting Management", KATS, ~ (2018)
  17. Lee, K. W., "Comparing 2-cc coupler gain of monaural fitting with non-linear fitting formulas for elderly Korean with SNHL", Audiology, 4(1), pp.69~73 (2008)
  18. Marriage, J., "Comparison of three procedures for initial fitting of compression hearing aids. III. Inexperienced versus experienced users", International Journal of Audiology, 43(4), pp.198~210 (2004)
  19. Mueller, H. G., "Consideration of auditory acclimatization in the prescriptive fitting of hearing aids", Seminars in Hearing, 22(2), pp.103~124 (2001)
  20. 박유진, "건청인과 감각신경성난청 성인의 청력역치에 따른 음량증가의 변화", Audiology and Speech Research, 9(1), pp.25~32 (2013), 한국청각언어재활학회
  21. Reber, M. B., "Acclimatization in first-time hearing aid users using three different fitting protocols", Auris, Nasus, Larynx, 32(4), pp.345~351 (2005)
  22. Sanders, J., "Manufacturers’NAL-NL2 fittings fail real-ear verification", Hearing Review, 21(3), pp.24~32 (2015)
  23. Saunders, G. H., "Acclimatization to hearing aids", Ear and Hearing, 18(2), pp.129~139 (1997)
  24. 심상익, "A Study of Korean Hearing Aid Satisfaction Survey Based on MarkeTrak VIII", Audiology and Speech Research, 16(1), pp.48~57 (2020), 한국청각언어재활학회
  25. Souza, P. E., "Effects of compression on speech acoustics, intelligibility, and sound quality", Trends in Amplification, 6(4), pp.131~165 (2002)
  26. Wright, D., "Acclimatization to hearing aids by older adults", Ear and Hearing, 42(1), pp.193~205 (2021)

관련 논문AI추천

Changes in Speech Recognition Scores and Sound Quality According to Gain Adjustment in High Frequency Bands이경원, Eunchul Choi, Hyeryeong Jo, Hyungoo Lee, Jihun Kim, Mikyung Lee한국청각언어재활학회 · Audiology and Speech Research2022 · 제18권 제2호A Study on the Preferred Real-Ear Insertion Gain of Multi-Channel Hearing Aid for the Korean with Sensorineural Hearing Loss이경원, 방어지니한국청각언어재활학회 · Audiology and Speech Research2020 · 제16권 제2호Comparison of Preferred Real-Ear Insertion Gain between Open- and Closed-Canal Fitting Hearing Aids이경원, Hyekyung Kong, Hyeryeong Jo, Hyungoo Lee, Kwangjae Kim, Mikyung Lee, Soohyun Ahn, Suyeon Shin한국청각언어재활학회 · Audiology and Speech Research2021 · 제17권 제2호Difference Between the Preferred Gain and the NAL-NL2 Gain in Korean Hearing Aid Users송재준, 이종근, 전재민, 채성원대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2022 · 제65권 제7호Preferred Compression Threshold and Release Time in Quiet and Noisy Conditions for Elderly Korean Hearing Aid Users김동욱, 김진숙, 이경원, 이정학, 한우재대한청각학회 · Journal of Audiology & Otology2017 · 제21권 제3호Changes of the Korean Consonant-Vowel Syllabic Recognition Scores According to the Compression Threshold Control of Multi-Channel Hearing Aid윤다정, 이경원한국청각언어재활학회 · Audiology and Speech Research2020 · 제16권 제4호