Background: Automated blood cell analyzers often read leukemic blasts as normal cells. In this study, we evaluated the 5-part differential patterns of blasts using automated analyzers to determine if they can differentiate among blast types. Methods: Blood samples containing 10% or more blasts were collected from patients with acute leukemia (N=175). The 5-part differential count was conducted using DxH 800 (Beckman Coulter, USA) and XE-2100 analyzers (Sysmex Co., Japan), and the results were compared with manual differential counts, which was used as a reference method. Results: The DxH 800 reported the 5-part white blood cell differential count in 98.9% of the cases. The XE-2100 provided an invalid automated differential count in 72% of the cases. Both analyzers counted most lymphoblasts as lymphocytes and most myeloblasts as monocytes. In 11 cases, the DxH 800 reported a 5-part differential count without a blast flag. Conclusions: Some automated analyzers are able to recognize and count blasts according to their characteristic cell types. Therefore, complete blood counts obtained automatically can provide valuable data for making provisional decisions regarding the lineage of leukemia cells before further investigation.(Korean J Lab Med 2010;30:540-6)

Abstract

Background: Automated blood cell analyzers often read leukemic blasts as normal cells. In this study, we evaluated the 5-part differential patterns of blasts using automated analyzers to determine if they can differentiate among blast types. Methods: Blood samples containing 10% or more blasts were collected from patients with acute leukemia (N=175). The 5-part differential count was conducted using DxH 800 (Beckman Coulter, USA) and XE-2100 analyzers (Sysmex Co., Japan), and the results were compared with manual differential counts, which was used as a reference method. Results: The DxH 800 reported the 5-part white blood cell differential count in 98.9% of the cases. The XE-2100 provided an invalid automated differential count in 72% of the cases. Both analyzers counted most lymphoblasts as lymphocytes and most myeloblasts as monocytes. In 11 cases, the DxH 800 reported a 5-part differential count without a blast flag. Conclusions: Some automated analyzers are able to recognize and count blasts according to their characteristic cell types. Therefore, complete blood counts obtained automatically can provide valuable data for making provisional decisions regarding the lineage of leukemia cells before further investigation.(Korean J Lab Med 2010;30:540-6)

참고문헌 (15)

  1. McClatchey KD, "Clinical laboratory medicine. 2nd ed", pp.809~ (2002), Lippincott Willimas and Wilkins
  2. Briggs C, "Can automated blood film analysis replace the manual differential? An evaluation of the CellaVision DM96 automated image analysis system", Int J Lab Hematol, 31, pp.48~60 (2009)
  3. Novis DA, "Laboratory productivity and the rate of manual peripheral blood smear review: a College of American Pathologists Q-Probes study of 95,141 complete blood count determinations performed in 263 institutions", Arch Pathol Lab Med, 130, pp.596~601 (2006)
  4. Lantis KL, "Elimination of instrument-driven reflex manual differential leukocyte counts. Optimization of manual blood smear review criteria in a high-volume automated hematology laboratory", Am J Clin Pathol, 119, pp.656~662 (2003)
  5. Pierre RV, "Peripheral blood film review. The demise of the eyecount leukocyte differential", Clin Lab Med, 22, pp.279~297 (2002)
  6. Kakkar N, "Utility of white blood cell suspect flags and histogram pattern in the detection of acute leukemia by Advia-60 automated hematology analyzer", Indian J Pathol Microbiol, 47, pp.322~326 (2004)
  7. Kline A, "Identification of blast cells in the peripheral blood of patients with acute leukaemia using the Technicon H-1", Clin Lab Haematol, 11, pp.111~116 (1989)
  8. Hoyer JD, "Detection and classification of acute leukemia by the Coulter STKS Hematology Analyzer", Am J Clin Pathol, 106, pp.352~358 (1996)
  9. Swerdlow SH, "WHO Classification of Tumours of Haematopoietic and Lymphoid Tissues. 4th ed", pp.110~178 (2008), IARC
  10. Gibbs G, "Differences in detecting blasts and the role of cytogram analysis", Int J Hematol, 32, pp.271~272 (2010)
  11. Inoue H, "Overview of automated hematology analyzer XE-2100TM", Sysmex J Int, 9, pp.58~64 (1999)
  12. Herklotz R, "Precision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100", Sysmex J Int, 11, pp.8~21 (2001)
  13. Jean A, "The new haematology analyzer DxH800: an evaluation of the analytical performances and leucocyte flags, comparison with the LH755", Int J Lab Hematol (2010)
  14. Hedley BD, "Initial performance evaluation of the UniCel((R)) DxH 800 Coulter((R)) cellular analysis system", Int J Lab Hematol (2010)
  15. Barnes PW, "The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis", Lab Hematol, 11, pp.83~90 (2005)

관련 논문AI추천

Validation of Hematology Rapid Reporting System for Complete Blood Cell Count with Differential김지용, 박지영, 윤수영, 이정민대한진단검사의학회 · Laboratory Medicine Online2022 · 제12권 제1호Flow Cytometric White Blood Cell Differential Using CytoDiff is Excellent for Counting Blasts강지민, 김명신, 김용구, 박연준, 오은지, 한경자대한진단검사의학회 · Annals of Laboratory Medicine2015 · 제35권 제1호Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method고광상, 김수화, 김용구, 박연준, 박종문, 심양보, 임지향, 조용준, 한경자대한진단검사의학회 · Annals of Laboratory Medicine2011 · 제31권 제3호Large Unstained Cell, Blast Suspect and Delta Neutrophil Index ll Analyzed with Automated Hematology Analyzer as Parameters for the Prediction of Acute Leukemia Relapse김유경, 서장수, 황나래대한진단검사의학회 · Laboratory Medicine Online2019 · 제9권 제3호Performance Evaluation of the Mindray BC-6200 Hematology Analyzer; Comparison with Sysmex XE-2100 and Manual Microscopy김한아, 박미경, 이창훈, 이태환, 허미나대한진단검사의학회 · Laboratory Medicine Online2022 · 제12권 제4호Development of a Novel Flow Cytometry-Based System for White Blood Cell Differential Counts: 10-color LeukoDiff강지민, 김용구, 박동진, 박훈희, 장지영, 조애린, 한경자대한진단검사의학회 · Annals of Laboratory Medicine2019 · 제39권 제2호

이 간행물의 다른 논문 (28건)