PURPOSE. The aim of this study was to evaluate the influence of resin cement thickness on the microtensile bond strength between zirconium-oxide ceramic and resin cement. MATERIALS AND METHODS. Thirty-two freshly extracted molars were transversely sectioned at the deep dentin level and bonded to air-abraded zirconium oxide ceramic disks. The specimens were divided into 8 groups based on the experimental conditions (cement type: Rely X UniCem or Panavia F 2.0, cement thickness: 40 or 160 μm, storage: thermocycled or not). They were cut into microbeams and stored in 37℃ distilled water for 24 h. Microbeams of non-thermocycled specimens were submitted to a microtensile test, whereas those of thermocycled groups were thermally cycled for 18,000 times immediately before the microtensile test. Three-way ANOVA and Sheffe’s post hoc tests were used for statistical analysis (α=95%). RESULTS. All failures occurred at the resin-zirconia interface. Thermocycled groups showed lower microtensile bond strength than non-thermocycled groups (P<.001). Differences in cement thickness did not influence the resin-zirconia microtensile bond strength given the same resin cement or storage conditions (P>.05). The number of adhesive failures increased after thermocycling in all experimental conditions. No cohesive failure was observed in any experimental group. CONCLUSION. When resin cements of adhesive monomers are applied over air-abraded zirconia restorations, the degree of fit does not influence the resin-zirconia microtensile bond strength.

Abstract

PURPOSE. The aim of this study was to evaluate the influence of resin cement thickness on the microtensile bond strength between zirconium-oxide ceramic and resin cement. MATERIALS AND METHODS. Thirty-two freshly extracted molars were transversely sectioned at the deep dentin level and bonded to air-abraded zirconium oxide ceramic disks. The specimens were divided into 8 groups based on the experimental conditions (cement type: Rely X UniCem or Panavia F 2.0, cement thickness: 40 or 160 μm, storage: thermocycled or not). They were cut into microbeams and stored in 37℃ distilled water for 24 h. Microbeams of non-thermocycled specimens were submitted to a microtensile test, whereas those of thermocycled groups were thermally cycled for 18,000 times immediately before the microtensile test. Three-way ANOVA and Sheffe’s post hoc tests were used for statistical analysis (α=95%). RESULTS. All failures occurred at the resin-zirconia interface. Thermocycled groups showed lower microtensile bond strength than non-thermocycled groups (P<.001). Differences in cement thickness did not influence the resin-zirconia microtensile bond strength given the same resin cement or storage conditions (P>.05). The number of adhesive failures increased after thermocycling in all experimental conditions. No cohesive failure was observed in any experimental group. CONCLUSION. When resin cements of adhesive monomers are applied over air-abraded zirconia restorations, the degree of fit does not influence the resin-zirconia microtensile bond strength.

참고문헌 (26)

  1. Ozcan M, "Effect of surface conditioning methods on the bond strength of luting cement to ceramics", Dent Mater, 19, pp.725~731 (2003)
  2. Phark JH, "An in vitro evaluation of the long-term resin bond to a new densely sintered high-purity zirconium-oxide ceramic surface", J Prosthet Dent, 101, pp.29~38 (2009)
  3. Palacios RP, "Retention of zirconium oxide ceramic crowns with three types of cement", J Prosthet Dent, 96, pp.101~114 (2006)
  4. Piconi C, "Zirconia as a ceramic biomaterial", Biomaterials, 20, pp.1~25 (1999)
  5. Kosmac T, "The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic", Dent Mater, 15, pp.426~433 (1999)
  6. Janda R, "A new adhesive technology for all-ceramics", Dent Mater, 19, pp.567~573 (2003)
  7. Kern M, "Bonding to zirconia ceramic: adhesion methods and their durability", Dent Mater, 14, pp.64~71 (1998)
  8. Al-Dohan HM, "Shear strength of core-veneer interface in bi-layered ceramics", J Prosthet Dent, 91, pp.349~355 (2004)
  9. Oh WS, "Effect of surface topography on the bond strength of a composite to three different types of ceramic", J Prosthet Dent, 90, pp.241~246 (2003)
  10. Valandro LF, "The effect of ceramic surface treatment on bonding to densely sintered alumina ceramic", J Prosthet Dent, 93, pp.253~259 (2005)
  11. Guazzato M, "Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina", zirconia-reinforced dental ceramic, 2005, pp.21, 454~463
  12. Burke FJ, "Are adhesive technologies needed to support ceramics? An assessment of the current evidence", J Adhes Dent, 4, pp.7~22 (2002)
  13. Oyagu¨e RC, "Effect of water aging on microtensile bond strength of dualcured resin cements to pre-treated sintered zirconium-oxide ceramics", Dent Mater, 25, pp.392~399 (2009)
  14. Wolfart M, "Durability of the resin bond strength to zirconia ceramic after using different surface conditioning methods", Dent Mater, 23, pp.45~50 (2007)
  15. Yang B, "Influence of air-abrasion on zirconia ceramic bonding using an adhesive composite resin", Dent Mater, 26, pp.44~50 (2010)
  16. Amaral R, "Effect of conditioning methods on the microtensile bond strength of phosphate monomer-based cement on zirconia ceramic in dry and aged conditions", J Biomed Mater Res B Appl Biomater, 85, pp.1~9 (2008)
  17. Aboushelib MN, "Selective infiltration-etching technique for a strong and durable bond of resin cements to zirconia-based materials", J Prosthet Dent, 98, pp.379~388 (2007)
  18. Wegner SM, "Effect of different artificial aging conditions on ceramic-composite bond strength", Int J Prosthodont, 15, pp.267~272 (2002)
  19. Lu¨thy H, "Effect of thermocycling on bond strength of luting cements to zirconia ceramic", Dent Mater, 22, pp.195~200 (2006)
  20. Leinfelder KF, "A new method for generating ceramic restorations: a CAD-CAM system", J Am Dent Assoc, 118, pp.703~707 (1989)
  21. Molin MK, "Influence of film thickness on joint bend strength of a ceramic", resin composite joint, 1996, pp.12, 245~249
  22. Reich S, "Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD", CAM systems, 2005, pp.113, 174~179
  23. Kohorst P, "Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses", J Oral Rehabil, 37, pp.293~291 (2010)
  24. Wettstein F, "Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures", Eur J Oral Sci, 116, pp.272~279 (2008)
  25. Sailer I, "Five-year clinical results of zirconia frameworks for posterior fixed partial dentures", Int J Prosthodont, 20, pp.383~388 (2007)
  26. Feilzer AJ, "Setting stress in composite resin in relation to configuration of the restoration", J Dent Res, 66, pp.1636~1639 (1987)

관련 논문AI추천

Impact of multiple firings and resin cement type on shear bond strength between zirconia and resin cementsEce İrem Oğuz, Merve Erdoğ Özgür, Sadullah Üçtaşlı, Sercan Sungur대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제4호Evaluation of shear bond strength between dual cure resin cement and zirconia ceramic after thermocycling treatment강철균, 박주미, 서재민, 오주원, 이정진대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제1호Shear bond strength of zirconia to resin: The effects of specimen preparation and loading procedureBingzhuo Chen, Chen Chen, Haifeng Xie, Hongliang Meng, Lu Yang, Xinyi Wu, Zhicen Lu대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제6호Effects of air-abrasion pressure on the resin bond strength to zirconia: a combined cyclic loading and thermocycling aging studyAfnan O. Al-Zain, Alaa H. Sabrah, Eman Z. Al-Shehri, George J. Eckert, Jeffrey A. Platt, Laila Al Dehailan, Marco C. Bottino, Mutlu Özcan, Sarah S. Al-Angari대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제3호The effect of repeated surface treatment of zirconia on its bond strength to resin cementDaher Antonio Queiroz, Kusai Baroudi, Laís Regiane Silva-Concílio, Lucas Campagnaro Maciel, Marina Amaral대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제5호Effect of zirconia surface treatment using nitric acid-hydrofluoric acid on the shear bond strengths of resin cements김선재, 심준성, 이근우, 조진형대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제2호

이 간행물의 다른 논문 (10건)