Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colors
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS. A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (α=.05). RESULTS. In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to 20.88 μm), of which the marginal and internal variations ranged 51.36 - 58.26 μm and 18.33 - 20.04 μm, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than 5 μm, of which blue color group was the smallest (3.27 ± 0.24 μm) and white color group was the largest (4.24 ± 0.36 μm). These results were consistent with the DS data. CONCLUSION. The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.
Abstract
PURPOSE. The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS. A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (α=.05). RESULTS. In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to 20.88 μm), of which the marginal and internal variations ranged 51.36 - 58.26 μm and 18.33 - 20.04 μm, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than 5 μm, of which blue color group was the smallest (3.27 ± 0.24 μm) and white color group was the largest (4.24 ± 0.36 μm). These results were consistent with the DS data. CONCLUSION. The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.
참고문헌 (35)
- 김소연, "Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model", The Journal of Advanced of Prosthodontics, 6(1), pp.1~7 (2014), 대한치과보철학회[DOI]
- Keshvad A, "Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques", J Prosthodont, 20, pp.535~540 (2011)[DOI]
- Eisenburger M, "Comparative study of wear of enamel induced by alternating and simultaneous combinations of abrasion and erosion in vitro", Caries Res, 37, pp.450~455 (2003)[DOI]
- Bartlett DW, "Measurement of tooth wear in patients with palatal erosion", Br Dent J, 182, pp.179~184 (1997)[DOI]
- Azzopardi A, "The measurement and prevention of erosion and abrasion", J Dent, 29, pp.395~400 (2001)[DOI]
- Mehl A, "A new optical 3-D device for the detection of wear", J Dent Res, 76, pp.1799~1807 (1997)[DOI]
- Pintado MR, "Variation in tooth wear in young adults over a two-year period", J Prosthet Dent, 77, pp.313~320 (1997)[DOI]
- Schlueter N, "Evaluation of a profilometrical method for monitoring erosive tooth wear", Eur J Oral Sci, 113, pp.505~511 (2005)[DOI]
- McBride J, "The 3D measurement and analysis of high precision surfaces using con-focal optical methods", IEICE transactions on electronics, 87, pp.1261~1267 (2004)
- DeLong R, "Factors influencing optical 3D scanning of vinyl polysiloxane impression materials", J Prosthodont, 10, pp.78~85 (2001)[DOI]
- Heintze SD, "Surface roughness and gloss of dental materials as a function of force and polishing time in vitro", Dent Mater, 22, pp.146~165 (2006)[DOI]
- Wieland M, "Wavelength-dependent roughness: a quantitative approach to characterizing the topography of rough titanium surfaces", Int J Oral Maxillofac Implants, 16, pp.163~181 (2001)
- Rodriguez JM, "Surface roughness of impression materials and dental stones scanned by non-contacting laser profilometry", Dent Mater, 25, pp.500~505 (2009)[DOI]
- Kim JH, "Influence of various gypsum materials on precision of fit of CAD", CAM-fabricated zirconia copings, 2015, pp.34, 19~24
- Schaefer O, "Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility", Dent Mater, 28, pp.320~326 (2012)[DOI]
- Schaefer O, "Three-dimensional fit of lithium disilicate partial crowns in vitro", J Dent, 41, pp.271~277 (2013)[DOI]
- Schaefer O, "Effect of CNC-milling on the marginal and internal fit of dental ceramics: a pilot study", Dent Mater, 29, pp.851~858 (2013)[DOI]
- Wadhwani CP, "Accuracy of newly formulated fast-setting elastomeric impression materials", J Prosthet Dent, 93, pp.530~539 (2005)[DOI]
- Millar BJ, "The effect of a surface wetting agent on void formation in impressions", J Prosthet Dent, 77, pp.54~56 (1997)[DOI]
- Cho SH, "Comparison of accuracy and reproducibility of casts made by digital and conventional methods", J Prosthet Dent, 113, pp.310~315 (2015)[DOI]
- Guth JF, "Accuracy of digital models obtained by direct and indirect data capturing", Clin Oral Investig, 17, pp.1201~1208 (2013)[DOI]
- Beuer F, "Marginal and internal fits of fixed dental prostheses zirconia retainers", Dent Mater, 25, pp.94~102 (2009)[DOI]
- Abdel-Azim T, "Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD", CAM technology by using conventional impressions and two intraoral digital scanners, 2015, pp.114, 554~559
- Tsirogiannis P, "Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: A systematic review and meta-analysis", J Prosthet Dent, 116, pp.328~335 (2016)[DOI]
- Rajan BN, "Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: An in vitro study", J Indian Prosthodont Soc, 15, pp.173~178 (2015)[DOI]
- Shembesh M, "An in vitro comparison of the marginal adaptation accuracy of CAD", CAM restorations using different impression systems, 2017, pp.26, 581~586
- Yildiz C, "Marginal-internal adaptation and fracture resistance of CAD", CAM crown restorations, 2013, pp.32, 42~47
- Vanlioglu BA, "Internal and marginal adaptation of pressable and computeraided design", computer-assisted manufacture onlay restorations, 2012, pp.25, 262~264
- Alghazzawi TF, "The effect of different fabrication steps on the marginal adaptation of two types of glass-infiltrated ceramic crown copings fabricated by CAD", CAM technology, 2012, pp.21, 167~172
- Soares CJ, "Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations", J Prosthet Dent, 95, pp.421~429 (2006)[DOI]
- Bender IB, "Clinical considerations in the diagnosis and treatment of intra-alveolar root fractures", J Am Dent Assoc, 107, pp.595~600 (1983)[DOI]
- Schaefer O, "Qualitative and quantitative three-dimensional accuracy of a single tooth captured by elastomeric impression materials: an in vitro study", J Prosthet Dent, 108, pp.165~172 (2012)[DOI]
- Report of a special test. NIST Test 2010;681, "280055-10", Phillips S, 2010
- Ender A, "Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision", J Prosthet Dent, 109, pp.121~128 (2013)[DOI]
- Ender A, "Full arch scans: conventional versus digital impressions-an in-vitro study", Int J Comput Dent, 14, pp.11~21 (2011)